2  RSPF Series Catalog Number 

Each Eaton RSPF Series SPD is identified by a Catalog 
Number, see example in 

Table 1

.  The Catalog Number 

identifies the parameters that make up the unit. 

Table 1. Catalog Numbering System 

 

 

 

For example, an RSPF Series SPD with a Catalog 
Number of RSPF2403MA1A, where: 

RSP = RSP Series 

F = Surge Frame 

240 = Voltage Code 

3 = Number of Phases 

MA = Type and current rating of panel 

1 = Feature Package 

A = Application 

See 

Section 10

Ordering Guidelines

 for additional 

voltages, features, and service options. 

3  RSPF Series Product Nameplate 

Each Eaton RSPF Series SPD has a Product Nameplate 
affixed to the front of the unit that identifies Catalog 
Number and operating parameters.  The Catalog 
Number consists of letters and numbers which identify 
the RSPF Series, surge frame, voltage code, number of 
phases, panel bus rating, feature package, and 
application as shown in 

Figure 1

 

 

 

Figure 1. RSPF Series Product Nameplate 

 

4  Installation 

WARNING 

A LICENSED/QUALIFIED ELECTRICIAN MUST 
COMPLETE ALL INSTRUCTIONS IN THIS MANUAL 
IN ACCORDANCE WITH THE NATIONAL ELECTRIC 
CODE (NEC), CANADIAN ELECTRICAL CODE (CEC), 
STATE, AND LOCAL CODES, OR OTHER 
APPLICABLE COUNTRY CODES.  ALL APPLICABLE 
LOCAL ELECTRICAL CODES SUPERSEDE THESE 
INSTRUCTIONS. 

INSTALLING AN SPD THAT IS IMPROPERLY RATED 
FOR THE ELECTRICAL SYSTEM VOLTAGE COULD 
CREATE A POTENTIALLY HAZARDOUS CONDITION, 
RESULTING IN INJURY OR EQUIPMENT DAMAGE. 

CHECK THE VOLTAGE-RATING LABEL LOCATED 
ON THE FRONT OF THE SPD TO VERIFY THAT THE 
ELECTRICAL SYSTEM’S VOLTAGE AND WIRING 
CONFIGURATION ARE THE SAME AS THE SPD. 

FOR USE ON CIRCUITS DELIVERING UP TO 200,000 
RMS AMPS.  CONVIENT Á DES CIRCUITS 
PRODUCISANT AU PLUS 200,000 A EFF. 
 
BEFORE MOUNTING THE SPD IN AN ELECTRICAL 
SYSTEM MAKE SURE THERE IS NO VOLTAGE 
PRESENT WHERE WORK IS TO BE PERFORMED.  
VOLTAGES IN ENERGIZED EQUIPMENT CAN 
CAUSE INJURY OR DEATH. 

4.1 

Pre-Installation Checklist 

o

 

Does the panelboard have a 3 pole FD Frame 
breaker space available. 
 

o

 

Does the panelboard have a panel with an 
opening that will allow the front of a RSPF 
Series SPD to protrude through after installation. 
 

o

 

Does the panelboard have 3 pole FD-Frame 
phase connectors. 
 

o

 

If the answer was “No” to any of the three 
previously listed conditions, contact the 
EatonCare Technical Resource Center at: 1-
800-809-2772, Option 4, sub-option 2 to 
purchase either Connector Kit 

Catalog#: 

KPRL3AFD3

 (3-pole) for use in panel type 

PRL3a or Connector Kit 

Catalog#: KPRL4FD

 

(3-pole) for use in panel type PRL4.  These 
connector kits include phase connectors, 
deadfront cover, filler covers, hardware and 
instruction sheet. 
 
 
 

Содержание RSPF Series

Страница 1: ...ffective Date December 2017 For more information visit www eaton com RSPF Installation Instructions for Eaton RSPF Series Surge Protective Device SPD Instruction Leaflet IL158004EN Rev 2 December 2017...

Страница 2: ...ted to the Ground Bus 5 Figure 9 Surge Ground Terminal connected to the Neutral Bus 5 5 Operation 5 5 1 Power Up and System Checkout 5 5 2 Alarm Silence Pushbutton 5 6 Specifications 6 7 Maintenance 6...

Страница 3: ...nditions but will maintain power to the load now unprotected from surge events The Eaton RSPF Series SPD is available in voltage ratings from 208Vac to 600Vac and surge current ratings of 50kA and 100...

Страница 4: ...NTRY CODES ALL APPLICABLE LOCAL ELECTRICAL CODES SUPERSEDE THESE INSTRUCTIONS INSTALLING AN SPD THAT IS IMPROPERLY RATED FOR THE ELECTRICAL SYSTEM VOLTAGE COULD CREATE A POTENTIALLY HAZARDOUS CONDITIO...

Страница 5: ...AUSE INJURY OR DEATH USE APPROPRIATE SAFETY PRECAUTIONS AND EQUIPMENT FOR ARC FLASH PROTECTION 4 3 Mounting 1 Locate the electrical system s applicable block diagram in Section 5 Wiring Diagrams 2 Tur...

Страница 6: ...tripe 10 AWG insulated conductor Keeping the wire length as short as possible Torque the Surge Ground Terminal screw to 35 lb in See Figure 6 11 2 When wiring to the Neutral Bar use a white 10 AWG ins...

Страница 7: ...nnections and test again Verify that the proper voltage is present If the panel is energized properly and the LEDs still do not light contact EatonCare Technical Resource Center at 1 800 809 2772 Opti...

Страница 8: ...under warranty 8 Liability This instruction leaflet is published solely for information purposes and should not be considered all inclusive If further information is required you should consult Eaton...

Страница 9: ...ailable at www eaton com Current Eaton Panelboards Renewal Parts RP01400001E Eaton Renewal Parts Data Panelboard Renewal Parts Supplement RP01414001E Vintage Cutler Hammer panelboards and switchboards...

Страница 10: ...stitute any warranty by or impose any liability upon Eaton AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY AS TO THE MERCHANTABILITY FITNESS FOR PURPOSE SOLD PRODUCTIVE N...

Страница 11: ......

Страница 12: ...ownship PA 15108 4312 USA www eaton com RSP 2017 Eaton Corporation For additional information please call All Rights Reserved Eaton s Power Quality Technical Support Publication No IL158004EN 1 800 80...

Отзывы: