background image

The configurable values are as following:

Remember the last status:

Parameter

Size

Range

Default

13

1

1/0

1: remember (0: do not remember)

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1: This device may not cause harmful interference, and

2: This device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment 

generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

FCC CAUTION:

Any changes or modifications not expressly approved by Eaton Wiring Devices could void the user’s authority to operate the equipment This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions:

(1) This device may not cause interference; and

(2) This device must accept any interference, including interference that may cause undesired operation of the device.

RADIATION EXPOSURE STATEMENT:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. 

INDUSTRY CANADA STATEMENT:

This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, 

y compris un brouillage susceptible de provoquer un fonctionnement indésirable. 

RADIATION EXPOSURE STATEMENT:

This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

DÉCLARATION D’EXPOSITION AUX RADIATIONS:

Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.

WARNING:

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed 

of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take 

back your old appliance for disposal at least for free of charge.

www.eaton.com

www.eaton.com/wiringdevices

EIS-0245-E (REV. B)

Troubleshooting Guides

The table below lists the several steps involved when adding or removing the unit  from the Z-Wave network.

Action/Status

Description

LED indication

No node ID Status

The unit has not been added to the Z-Wave 

network

2-second ON,  

2-second OFF

Auto Inclusion

Inclusion starts immediately when power is 

applied for the first time (This occurs only if no 

node ID is stored in the module, usually after  

Exclusion or after executing a Factory Reset) 

Manual Inclusion

If auto inclusion fails: 

1. Put the Z-Wave Controller into Inclusion mode

2. Press the ON/OFF button 3 times within  

1.5 seconds to put the unit into Inclusion mode

Exclusion

1. Put the Z-Wave Controller into Exclusion mode

2. Press the ON/OFF button 3 times within  

1.5 seconds to put the unit into Exclusion mode

Factory Reset

(Please use this procedure 

only when the network pri-

mary controller is missing 

or otherwise inoperable)

1. Press the ON/OFF button 3 times within  

1.5 seconds to put the unit into exclusion mode 

2. Within 1 second of step 1, press and hold the 

button for 5 seconds

3. Node ID is deleted. The device reverts to factory 

default state

2-second ON,  

2-second OFF

* Failure or success in including/excluding the ID can be viewed on the Z-Wave Controller.

Note:

 If you are connecting this unit to a Z-wave Controller that utilizes the S2 security protocol, you may be 

asked to enter a 5 digit Device Specific Key (DSK) that is unique to each unit by your controller.  

This can be found in one of two places:

- on the QR code label on the back of the unit

- on the insert card inside the packaging

EATON WIRING DEVICES LIMITED 2 YEAR WARRANTY

Eaton Wiring Devices warrants its switch to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS TWO (2) YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR 

LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESEN-

TATIVE, OR EMPLOYEE OF EATON HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF EATON UNDER THIS WARRANTY.

To obtain warranty service for any properly installed Eaton switch that proves defective in normal use send the defective switch prepaid and insured to Quality Control Dept., Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 

McLaughlin Road, Mississauga, Ontario L5R 1B8. Eaton will repair or replace the defective unit, at its option. Eaton  will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation, altera-

tion, improper maintenance or repair of damage in shipment to Eaton. EATON SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE SWITCH, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL, CONTINGENT, OR CONSEQUENTIAL 

DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE SWITCH OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT.

THE EXCLUSIVE REMEDY FOR BREACH OF THE LIMITED WARRANTY CONTAINED HEREIN IS THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT AT EATON’S OPTION. IMPLIED WARRANTIES (IF ANY) INCLUDING, BUT NOT LIMITED TO IMPLIED WARRANTIES OF 

FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABIITY, ARE LIMITED IN DURATION TO A PERIOD ENDING TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. IN NO CASE SHALL EATON’S LIABILITY UNDER ANY OTHER REMEDY PRESCRIBED BY LAW 

EXCEED THE PURCHASE PRICE. Some states do not allow the exclusion or limitation of incidental or consequential damages or allow disclaimers or modifications of or limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Some Canadian 

provinces do not allow exclusion or variance of implied warranties so that some or all of the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state and province to province.

Read enclosed instructions carefully. If you have any questions concerning use or care of this product, please write: Consumer Service Division, Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA  30269.

Table below lists typical problems encountered:

Symptoms

Possible Cause

Solution

The unit is not working and LED 

is always off even when knob is 

pressed.

The unit is not plugged into the 

electrical outlet properly

Check power connections to the unit

The unit’s LED turns on but 

connected appliance does not 

turn ON

1. The connected appliance 

has its own power switch set 

to OFF

2. The appliance requires a 

separate remote control to turn

1. Set the ON/OFF switch of the  

appliance itself to ON position

2. Appliances turned ON/OFF by with 

remote control cannot be controlled 

by this ON/OFF plug module

The module works if operated 

manually but cannot be 

controlled wirelessly by end  

devices in Group 2 mode

1. Z-Wave Association process 

was not implemented

2. Frequency interference

3. Out of range

1. Carry out Z-Wave Association

2. Wait for a while to re-try

3. Move the device or module closer 

to each other

Specification

Operating Voltage

120V AC, 60Hz

Maximum Load

1400W

Range

Up to 100 meters line of sight

Frequency Range

US: 908.42 MHz

FCC ID

UH2-RF96APM

IC

4706C-RF96APM

* Specifications are subject to change without notice

Отзывы: