Assembly Procedures

Step 1: 

Using a tube cutter, make a square cut 

edge (maximum 15˚ cutting angle allowed).

Note: 

Dull knives, side-cutters, or other cutting tools  
may NOT ensure a good, clean cut. Burrs, oval 
tubing, and contamination can damage seals  
and other system components.

Tube Insertion

Gentle Tug

90˚

15˚ 

max.

Collet

Tube Support

O-Ring

Body

Step 5: 

Allow the tube ample room for  

a gradual bend. 

Note: 

Severe bends can collapse tubing, 
resulting in leaks, line blockage, or  
flow restriction. 

Step 2: 

Insert tubing straight into fitting until  

a solid stop is felt. The tubing grip  

and seal (on the O-ring) is now 

accomplished. 

Step 3: 

Gently tug on tubing to ensure  

tubing is secure.

Parts Reference 

Step 4: 

Install threaded end of fitting hand 

tight and make final adjustment with 

wrench on hex or flats of fitting body. 

Note: 

Never use a wrench near the  
tubing entry or collet head of fitting.

Disassembly Procedures

Step 1: 

Check to be sure there is no  

air pressure.

Step 2: 

Depress collet head using fingers  

or Weatherhead

®

 tube-release tool

to release grip on tubing. 

Step 3: 

With the collet depressed,  

pull the tubing from the fitting.

Tube Release Tool

Keep Collet Depressed

Remove Tube

Keep Collet Depressed

Remove Tube