background image

                        

 

 

 
  
 

Power Xpert Ethernet Switch 

 

PXES6P Series 

 

Installation and User Guide 

 

           

 

 

Power Xpert Ethernet PXES6P Series Switch

  

Installation and User Guide

 

 

Trademarks

 

Ethernet is a trademark of Xerox Corporation 
NEBS is a trademark of Telcordia Technologies 
UL is a registered trademark of Underwriters Laboratories 

 
 
Important:

  The PXES6P Series 10/100 Mb/s Switches contains no user serviceable 

parts.  Attempted service by unauthorized personnel shall render all warranties null 
and void.  If problems are experienced with PXES6P 10/100 Mb/s Switch products, 
consult Section 5, troubleshooting, of this User Guide. 
 

 
Copyright 

©

 2006 EATON.  All rights reserved.  No part of this publication may be reproduced 

without prior written permission from Eaton. 

 

Printed in the United States of America. 

 

Federal Communications Commission 

Radio Frequency Interference Statement 

 

 

This equipment generates, uses and can radiate frequency energy and if not installed 

and used properly, that is in strict accordance with the manufacturer's instructions, may cause 

interference to radio communication.  It has been tested and found to comply with the limits for a 

Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC 

rules, which are designed to provide reasonable protection against such interference when 

operated in a commercial environment.  Operation of this equipment in a residential area is 

likely to cause interference, in which case the user, at his own expense, will be required to take 

whatever measures may be required to correct the interference. 

 

Содержание PXES6P24V

Страница 1: ...oduced without prior written permission from Eaton Printed in the United States of America 1 Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested a...

Страница 2: ... PXES6P with 24VDC power input 33 3 6 PXES6P Series 24VDC powered Installation 34 3 7 Connecting Ethernet Media 35 4 3 8 Connecting Twisted Pair RJ 45 CAT 3 or CAT 5 Unshielded or shielded 36 3 8 1 Connecting Fiber Optic ST type twist lock 38 3 8 2 Power Budget Calculations for PXES6P Series Fiber Media 39 3 8 3 Connections to NICs which support Auto Negotiation RJ 45 ports 40 4 0 OPERATION 42 4 1...

Страница 3: ...w to flush the internal address buffer and qualify to use with S Ring and RSTP for faster recovery in ring topology Maximum Ethernet Segment or Domain Lengths 10BASE T Unshielded twisted pair 100 m 328 ft 100BASE TX CAT 5 UTP 100 m 328 ft 100BASE FX half duplex multi mode 412 m 1350 ft 100BASE FX full duplex multi mode 2 km 6 562 ft 100BASE FX half duplex single mode 412 m 1350 ft 100BASE FX full ...

Страница 4: ...tory floor temperature rated Input 6ft AC 3power cord to IEC 320 connector on the 100 240vac 47 63Hz external power adapter Output 12vdc 1 25Amps Direct DC POWER SUPPLY Built in terminal Block for ground along with 24VDC jack 24V DC internal range 10 to 36V DC Power Consumption See Section 3 6 Note 1 the 12V DC jack can be used for dual source DC input using an AC adapter and the DC terminal block...

Страница 5: ...on PXES6P24V1ST 66A2303G01 6 port Ethernet Switch 5 copper 1 fiber ST PXES6P24V2ST 66A2305G01 6 port Ethernet Switch 4 copper 2 fiber ST PXES6P24V 66A2306G01 6 port Ethernet Switch copper only Accessories PXESPS12V 66A2318G01 External AC Power Supply PXESDINRL 66A2319G01 Din rail mount kit PXESTRAY 66A2320G01 Rack mount tray kit 13 2 0 INTRODUCTION This section describes PXES6P Series models inclu...

Страница 6: ...ns and is able to be conveniently DIN rail mounted to suit any application The Power Xpert Ethernet switches include Link Loss Learn LLL feature to qualify for any redundant and self healing managed network structures The Link Loss Feature in PXES6P allows the switches to flush the internal address buffers in milliseconds to permit a quick change in LAN packets flow and pass the reconfiguration si...

Страница 7: ...e as well as a set to indicate duplex for ports 1 and 2 only 10 100 indicates the speed for copper ports whereas F H indicates Full and Half duplex for fiber ports only There is a power PWR LED to indicate that the unit is turned ON The external DC power plug connector and or jack and the internal DC input terminal are provided on the rear of the unit Fig 2 2d shows PXES6P 2ST 19 2 3 Frame Bufferi...

Страница 8: ...e implemented in PXES6P Series Switches is a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving half duplex ports in order to stop incoming traffic The latency the time the frame spends in the Switch before it is sent al...

Страница 9: ...P enables monitoring for internal power failure and provides extra reliability to the hardened Switch Link Loss Learn feature for faster recovery in redundant managed network The LLL feature qualifies the switches to actively work along with redundant network structure as a client switch and allow a faster recovery during ring break 25 2 5 Applications for PXES6P Series Switches PXES6P Series Swit...

Страница 10: ...ps for panel mounting The compact and lightweight design of the PXES6P Series allows it to be easily installed 28 in almost any location A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet or for securing the unit on a table top or shelf Alternatively metal mounting clips and screws are included for a rugged and secure mounting in any orientation Instal...

Страница 11: ...e units are very close together 3 3 DIN rail mounting option The PXES6P Switches designed for use in Industrial Ethernet environments are available for DIN rail mounting A PXES6P is shown alongside the PXESDINRL bracket here The metal DIN rail mounting hardware is optional and needs to be ordered as a separate item e g 31 Model PXESDINRL It comes with four screws to attach the bracket to the unit ...

Страница 12: ...ts max 3 7 PXES6P Series 24VDC powered Installation This section describes the proper connection of the 24VDC leads to the DC power terminal block on the PXES6P Switch as shown in the Figure The DC terminal block on the PXES6P is located on the left side of the unit and is equipped with three 3 screw down lead posts The power terminals are identified as positive and negative and they are floating ...

Страница 13: ...work for both 10 Mbps and 100Mbps be used whenever possible in order to provide flexibility in a mixed speed network since PXES6P Series switch ports are auto sensing for either 10 and 100Mbps Note that the auto cross function does not operate if the port is fixed or not supporting auto negotiation 37 3 8 1 Connecting Twisted Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shielded The following procedure...

Страница 14: ...smitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using PXES6P Switches the following equations should be used OPB Optical Power Budget PT min PR min where PT Transmitter Output Power and PR Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in ...

Страница 15: ...te port and will not be sent to the other ports where it is not needed Packets needed for maintaining the operation of the network such as occasional multi cast packets are forwarded to all ports The PXES6P Series Switches operate in the store and forward switching mode which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Switching Add...

Страница 16: ...LA1 LA2 LA3 LA6 Steady On or steady Off indicates no Receive Activity 10 100 Steady ON for 100Mb speed OFF for 10Mb speed per port copper ports F H FH1 FH2 Steady ON for Full duplex F D mode OFF for Half duplex H D mode per port For fiber port only NOTE Ports 1 and 2 may be assigned as either copper or fiber ports depending upon the model If assigned as a copper port the 10 or 100 designation on L...

Страница 17: ...back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector ...

Страница 18: ...twork configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 5 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please contact customer support at 1 800 356 1243 option 4 Please have the following information ...

Страница 19: ...er shall pay all shipping charges duties and taxes for products returned to Eaton Corporation from another country Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer Buyer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or impro...

Страница 20: ...ll not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any other legal theory 57 Corporate Headquarters Eaton Electrical Inc 1000 Cherrington Parkway Moon Township PA 15108 Phone 1 800 525 2000 Website http www eatonelectrical com Publication 164201672 ...

Отзывы: