OPERATION 

1.  Find a suitable location for the PSFi. The PSFi requires free airflow for cooling. Do not stack items 

on top of the PSFi. 

2.  Connect load equipment to PSFi filter using appropriate leads. 
3.  Connect to a suitable power outlet. As the unit has no power switch, it is important that the power 

outlet’s switch be easily accessible. 

4.  Apply power. “Power’ indicator should light. If not, check connections or test power outlet with a 

known ‘good’ device. 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATION 

 

PSF10i 

PSF16i 

Number of ports 

2 Port 

Method of mounting 

Portable. 

Input voltage – Uc 

200-250VAC 1

 

Maximum continuous voltage – MCOV 

320VAC 

Temporary overvoltage - TOV 

350VAC 15 mins 

Service type 

Single-phase,  Line/Neutral/Earth 

Test classification 

Class III 

Nominal discharge current - In 8/20us 

I

n   

L-N  20kA, N-E 3kA, L-E  3kA 

Current rating - continuous 

10 Amps 

16 Amps 

Recommended maximum over current protection 

20A upstream circuit breaker or fuse. 

Residual current 

<0.5 mA 

Protection modes 

Line-Neutral, Line-Earth, Neutral-Earth 

Maxi surge current - Ismax 8/20us (Line-Neutral) 

40kA 

Nominal surge lifetime 

15 hits @ 20kA (8/20uS, each mode) 

Filter attenuation 

40dB nominal at 1MHz 

Initial clamp voltage (Line-Neutral) 

560V (350Vac RMS) 

Initial clamp voltage (Line-Earth, Neutral-Earth) 

680V (420Vac RMS) 

Residual voltage (Vpl) Line-Neutral 8/20us 

<900V @ 3kA 

Internal protection (fusing) 

Thermal fusing on primary MOVs 

Terminations 

Input  - IEC C14 10A (1) 

Output - IEC C13 10A (1) 

Input  - IEC C20 16A (1) 

Output - IEC C19 16A (1) 

Alarms/indicators 

2 part display, Power OK, Protection fault. 

Location Category 

Indoor 

Enclosure rating 

IP24 

Standards. Designed in accordance with : 

IEC61643-11, IEC610006-1,2,3,4 ANSI/IEEE C62.41 Cat B 

AS1768-1991 Cat B  AS3000,AS3100, 

Dimensions 

205mm (L) x 90mm (W)  x 55mm (H) 

Weight 

1kg 

Environment 

-10 to 50

C, 0 to 95%RH (non-condensing) 

Warranty 

1 year, workmanship and materials 

 
 

Specifications are subject to change without notice. Copyright 2015 Eaton Industries Pty Ltd

 

Two indicator lights are fitted to the unit for mains power and 
protection failure indication:  

Normal operation is indicated with the blue ‘Power On’ LED 
being lit.  

In the event of MOV failure, the 'Fault' LED will light to inform 
the operator that the unit requires replacement. 

IMPORTANT

:  If the ‘Fault’ light illuminates during operation, or 

the unit appears to malfunction in any way, return the unit for 
service or replacement.  

Service Hotline 1300 303 059. 