6 Parameter structure
6.4 Control signal terminals
DC1-S…20…, DC1-S…OE1 Variable Frequency Drives
05/21 MN040058EN
www.eaton.com
127
6.4.2 Configuration of the control signal terminals
6.4.2.1 P-12 = 0: Terminal-based operation
Table 33: P-12 = 0: Terminal-based operation
The setpoint and the control commands are set/issued via terminals.
P-15
DI1
(terminal 2)
DI2
(terminal 3)
DI3/AI2
(terminal 4)
DI4/AI1
(terminal 6)
0
START
No function
Select AI1 REF/f-Fix1
AI1 REF
1
START
Select AI1 REF/f-Fix
Select f-Fix Bit0
AI1 REF
2
START
Select f-Fix Bit0
Select f-Fix Bit1
Select f-Fix/f-max
3
START
Select AI1 REF/f-Fix1
EXTFLT
AI1 REF
4
START
Select AI1 REF/AI2 REF
AI2 REF
AI1 REF
5
START
Select Quick
‐
dec
Select AI1 REF/f-Fix1
AI1 REF
6
START
No function
EXTFLT
AI1 REF
7
START
Select Quick
‐
dec
EXTFLT
AI1 REF
8
START
No function
Select f-Fix Bit0
Select f-Fix Bit1
9
START
Select Quick
‐
dec
Select f-Fix Bit0
Select f-Fix Bit1
10
Pulse START (NO)
Pulse STOP (NC)
Select AI1 REF/f-Fix1
AI1 REF
11
Pulse START (NO)
Pulse STOP (NC)
Select Quick
‐
dec
AI1 REF
12
START
Select Quick
‐
dec
Select AI1 REF/f-Fix1
AI1 REF
13
START
Select f-Fix Bit0
EXTFLT
Select f-Fix Bit1
14
Pulse START (NO)
Pulse STOP (NC)
Select Quick
‐
dec
Select DIG REF/f-Fix1
15
START
Select f-Fix4/AI1 REF
Select Fire Mode/Normal OP
AI1 REF
16
START
Select f-Fix4/f-Fix2
Select Fire Mode/Normal OP
No function
17
START
Select f-Fix Bit0
Select Fire Mode/Normal OP
Select f-Fix Bit1
Содержание PowerXL