Eaton MEM Watchman 180 Скачать руководство пользователя страница 3

 

Angle - The head will rotate 45

 from either side of centre.  

A maximum of 180

 from 270

 can be covered 

 
45

0

 

 

0

 

 
45

0

 

C4 

C3 

B4 

B3 

A4 

A3 

C2 

C1 

A1 

Technical sheet no. October 03 

Watchman 180 Advanced Passive Infra Red Detector 

SETTING DETECTION AREA 

 
To reduce the range of the product, tilt the detector head 
forward. The angle of the tilt is shown on the side of the 
product. 

Both the range and detection angle can be blanked off by 
means of the self adhesive lens masking kit. Cut the        
appropriate sectors from the lens mask, to cover the area of 
the lens that requires masking. 

TESTING 

 
1.

Set the light level (yellow knob) to maximum 
(clockwise), and the time (blue knob) to minimum 
(anti-clockwise). 

2.

Move in and out of detection pattern, check the PIR 
detector switches load on and then off. Once the 
detection area has been set satisfactorily, adjust 
the light level (yellow knob) and the time (blue 
knob) to the desired levels. For your convenience 
optimum settings have been indicated. 

3.

If the unit does not operate, refer to check list and 
fault finding list. 

 

CHECK LIST 
 

1.

Check the supply in the detector 

2.

If testing the unit during daylight, ensure that the 
photocell has been adjusted in accordance with 
point (1) in ‘Testing’. 

3.

Check lamp is correctly fitted. 

 

FAULT FINDING LIST 
 
1.

The unit will not switch on - 

Check power is   

supplied to the unit. Check the plug-in connection, 
from the detector head, is joined correctly. Check 
that the bulb fitted to the lamp is not faulty and is 
correctly fitted.

 

2.

Unit is detecting at too long a range

 - Check 

mounting height and adjust angle of the unit    
downwards to reduce range. Note the unit is       
designed to switch at a maximum of 15m with 170lb 
(77kg person) walking at 90

 to the unit. A motor 

vehicle may be detected at a longer range.         
Alternatively fit an appropriate lens mask. 

 

 
            

Important Note - At 10

0

C this unit may detect in 

            excess of 20m 

A1 

A2 

A3 

A4 

B1 

B2 

B3 

B4 

C1 

C2 

C3 

C4 

90

0         

45

0   

        0         45

0  

     90

0

 

Long Range 6 - 15m 
 
 
Inner Range 3 - 12m 
 
 
Short Range 0 - 3m 

B1 

A2 

B2 

15m      12m           3m            3m            12m       15m 

Plan of Masking Effect 
See Diagram 1 

Diagram 1 

Masked Areas 

A3         A4 

B3         B4 
C3        C4 

Diagram 2 

Masked Areas 

A1         A2         A4 

B1         B2         B4 
C1        C2         C4 

15

m

 

15

m

 

90 

45 

Diagram 1A 

Diagram 2A 

45

0

 

90

0

 

Содержание MEM Watchman 180

Страница 1: ...angentially across the detection area Note Tangentially means moving at 90o C to detector Head on Approach 10m when mounted at 4m and tilted forward 10 o or 5m when mounted at 2 5m Detection Angle 180o Photocell Inhibit Adjustable between 30 and 300 Lux Street lighting switches at approximately 100 Lux Sensitivity This product can be sensitivity adjusted Operating Temp 20o C to 40o C IP Rating Sea...

Страница 2: ...ard with a 16A MCB or 20A rewirable fuse Cable size should be 2 5mm2 for 16amp 2 Remove screws and disconnect the plug connecting the detector to the back box When removing detector head latch on plug should be released as indicated below 3 Insert top screw into the wall allowing it to protrude by approximately 3mm Hook wall box onto screw using keyhole slot provided Mark position of remaining fix...

Страница 3: ...s not operate refer to check list and fault finding list CHECK LIST 1 Check the supply in the detector 2 If testing the unit during daylight ensure that the photocell has been adjusted in accordance with point 1 in Testing 3 Check lamp is correctly fitted FAULT FINDING LIST 1 The unit will not switch on Check power is supplied to the unit Check the plug in connection from the detector head is join...

Страница 4: ...ed patterns are given off by washing on the line trees blowing in the wind high winds and small animals Note To reduce sensitivity adjust the black adjuster screw on the rear of the unit anti clockwise 4 Unit will not switch off Are you standing in the detection zone Whilst you are moving in the detection area the unit will continue to detect The light off time is from the last moment detection is...

Отзывы: