Watchman 180 - Advanced Passive Infra Red  Detector 

Technical sheet no.  October 03 

Maximum load: 3500 Watts Tungsten Halogen 

or Tungsten at 240V AC 

or 

3200 Watts    

Tungsten Halogen 

or

 Tungsten at 220V 

Operating Voltage: 220V - 240V AC 

Operating Power:  3 Watts 

Load on Time: Adjustable to 10 sec. - 80 sec. -  

            3.5 mins - 6 mins - 9 mins - 12 mins - 13.5   
            mins  - 16 mins - 21 mins approx.           

Detection Range: 15m approximately, using 

standard target (At 10

o

C this unit may detect in 

excess of 20m. Range target is 77KG/170Ib 
person walking at 1ft (31cm) per second     
tangentially across the detection area).     

Note

: Tangentially means moving at 90

o

C to 

detector 

 

Head on Approach: 10m when mounted at 4m 

and tilted forward 10

 o

 

or 

5m when mounted at 

2.5m 

Detection Angle: 180

o

 

Photocell Inhibit: Adjustable between 30 and 

300 Lux—Street lighting switches at            
approximately 100 Lux 

Sensitivity: This product can be “sensitivity” 

adjusted 

Operating Temp: -20

o

C to +40

o

IP Rating: Sealed to IP54 

Min load 15VA if load consists of contactor 

only wire suppressor (RS part 210-364) in 
parallel with contactor coil.

 

5

o

0

o

10

o

20

o

30

o

45

o

. .

.

.

.

5

o

0

o

10

o

20

o

30

o

45

o

. .

.

.

.

Plug-in detector head 

Back box 

Each boxed product contains the following parts: 
1 x instruction sheet 
1 x grey wall box with fixed terminal block 
1 x Watchman 180 PIR switch with pre-wired male  
plug-in connection 
2 x screws to affix PIR switch to wall box 
3 x screw caps 
2 x lens mask 
1 x adjustment tool  

Содержание MEM Watchman 180

Страница 1: ...angentially across the detection area Note Tangentially means moving at 90o C to detector Head on Approach 10m when mounted at 4m and tilted forward 10 o or 5m when mounted at 2 5m Detection Angle 180o Photocell Inhibit Adjustable between 30 and 300 Lux Street lighting switches at approximately 100 Lux Sensitivity This product can be sensitivity adjusted Operating Temp 20o C to 40o C IP Rating Sea...

Страница 2: ...ard with a 16A MCB or 20A rewirable fuse Cable size should be 2 5mm2 for 16amp 2 Remove screws and disconnect the plug connecting the detector to the back box When removing detector head latch on plug should be released as indicated below 3 Insert top screw into the wall allowing it to protrude by approximately 3mm Hook wall box onto screw using keyhole slot provided Mark position of remaining fix...

Страница 3: ...s not operate refer to check list and fault finding list CHECK LIST 1 Check the supply in the detector 2 If testing the unit during daylight ensure that the photocell has been adjusted in accordance with point 1 in Testing 3 Check lamp is correctly fitted FAULT FINDING LIST 1 The unit will not switch on Check power is supplied to the unit Check the plug in connection from the detector head is join...

Страница 4: ...ed patterns are given off by washing on the line trees blowing in the wind high winds and small animals Note To reduce sensitivity adjust the black adjuster screw on the rear of the unit anti clockwise 4 Unit will not switch off Are you standing in the detection zone Whilst you are moving in the detection area the unit will continue to detect The light off time is from the last moment detection is...

Отзывы: