background image

4

EATON    

 IB516007EN 

    

 Installation instructions

Installation Instructions – LXF/LXT

Figure 5.   

Cupola Window To 

Face North

c.  Three-terminal block (3-wire service, 1 line, 

1 neutral, 1 ground): Connect line service lead to 

terminal that is connected to black factory-installed 

wire. Connect neutral service wire to terminal that is 

connected to white factory-installed wire. Connect 

ground service wire to terminal that is connected to 

green factory-installed wire.
d.  No terminal block (3-wire service, 2 lines, 1 

ground): Connect 1-line service lead to black factory-

installed wire. Connect other line service lead to white 

factory-installed wire. Connect ground service lead to 

green factory-installed wire.
e.  No terminal block (3-wire service, 1 line, 1 neutral, 

1 ground): Connect line service lead to black factory-

installed wire. Connect neutral service wire to white 

factory-installed wire. Connect ground service wire 

green factory-installed wire.

7.  For fixtures with asymmetric light patterns, locate the 

word “streetside” on the overhang plate and rotate the 

fixture on the pole such that the word “streetside” is 

facing the street.

8.  Secure the fixture to the pole top by tightening the 

three-square head bolt using 9/16” socket and torque 

wrench in the fixture base. Recommended tightening 

torque: 120-140 in-lbs.

9.  Reattach bottom cover plate to fixture base and secure 

with two cover retaining screws.

10.  Replace the lens panels in right-side.
11.  Close the cover carefully and secure with two cover 

retaining screws or secure spring latches.

Caution: Carefully and slowly close the hinged top cover. 

Always maintain contact and do not allow the hinged top 

cover swing freely as it can fall or damage.

12.  The fixture is now ready to energize.

Photocontrol Installation 

Tools Required: 

¼” Nut driver, #8 Flat head screwdriver.
When specified, the Lexington fixture is furnished with 

a rotatable photocontrol receptacle that allows the 

photocontrol to be properly positioned with the use of a 

straight blade screwdriver.
1.  Remove three hex nut screws using ¼” nut driver and 

lift off cupola. (Figure 3.)

2.  Remove the shorting cap (when furnished) and loosen 

the two flat head screws.

3.  Rotate the cupola until the window in the cupola is 

facing in a northerly direction. (Figure 5.) Line up the 

north arrow of the photocontrol receptacle with the 

window in the cupola. Retighten the screws and install 

the photocontrol. 

4.  Replace the cupola and tighten the cupola with three 

screws.

CAUTION: The receptacle has a built-in stop which allows 

350° rotation. Do not attempt to rotate beyond this stop as 

you will damage the receptacle.

Содержание LXF

Страница 1: ...the installation instructions specific to the catalog part that you ordered Note N The LXT LXF are designed to fit a 2 3 8 or 3 O D pole top or vertical tenon Note N Care must be taken not to set lig...

Страница 2: ...ree terminal block 2 wire service Connect line service lead to terminal that is connected to black factory installed wire Connect neutral service wire to terminal that is connected to white factory in...

Страница 3: ...iver surge module and or transformer attached inside of hinged top cover as it is open Always maintain contact 2 Gently lift the right side panel out of the slotted corner posts Figure 4 3 Reach botto...

Страница 4: ...using 9 16 socket and torque wrench in the fixture base Recommended tightening torque 120 140 in lbs 9 Reattach bottom cover plate to fixture base and secure with two cover retaining screws 10 Replace...

Страница 5: ...lips screws from LED 2 Install house side shield with provided 8 X Phillips screws Tighten until house shield is snug Do not over tighten Figure 6 Ladder Rest Installation Tools Required 5 16 Socket W...

Страница 6: ...s instructions d installation correspondant la pi ce du catalogue que vous avez command e Note N Les luminaires LXT LXF sont con us pour des t tes de poteau ou des tenons verticaux d un diam tre de 6...

Страница 7: ...appropri e avec le bloc de jonction Figure 2 a Plaque trois bornes deux fils de service Raccordez le fil de branchement la borne raccord e au fil noir install en usine Raccordez le fil de branchement...

Страница 8: ...poids du pilote de DEL du module de protection contre les surtensions et ou du transformateur qui sont fix s dans le couvercle sup rieur charni re pendant qu il est ouvert Maintenez toujours un conta...

Страница 9: ...lb po 9 Replacez le couvercle inf rieur la base du luminaire et fixez le avec deux vis de fixation du couvercle 10 Replacez les panneaux de lentilles dans le c t droit 11 Refermez d licatement le cou...

Страница 10: ...uis Douilles de 5 16 po cl 1 Ins rez un boulon m canique hexagonal de 5 16 18 x 1 po par les trous partir de l int rieur de la base du luminaire 2 Serrez l g rement un crou hexagonal de 5 16 18 sur le...

Страница 11: ...de instalaci n espec ficas para la pieza del cat logo que haya pedido Nota N Los LXT LXF est n dise ados para adaptarse a una O D de 2 3 8 o 3 polo superior o espiga vertical Nota N Se debe tener cuid...

Страница 12: ...bles Conecte el conector de servicio de l nea a la terminal que est conectada al cable negro instalado de f brica Conecte el cable de servicio neutro a la terminal que est conectada al cable blanco in...

Страница 13: ...r del LED el m dulo de sobretensi n y o el transformador conectado dentro de la cubierta superior con bisagra cuando est abierta Siempre mantenga el contacto 2 Levante suavemente el panel del lado der...

Страница 14: ...la luminaria Se recomienda un ajuste de par de torsi n de 120 140 in lbs 9 Vuelva a colocar la placa de cubierta inferior en la base de la luminaria y aseg rela con dos tornillos de retenci n de la c...

Страница 15: ...16 llave inglesa 1 Inserte un perno de cabeza hexagonal de 5 16 18 x 1 de largo a trav s de los agujeros desde el interior de la base de la luminaria 2 Enrosque sin apretar la tuerca hexagonal de 5 16...

Страница 16: ...das las marcas comerciales son propiedad de sus respectivos propietarios Product availability specifications and compliances are subject to change without notice La disponibilit du produit les sp cifi...

Отзывы: