i-on50EX/EXD
Installation
Page 23
Figure 39 FSL Zone Wiring
– Control Unit
Figure 40 shows the wiring connections for FSL
zones on the EXP-W10 expander. Note that the
connections are different on the expander
compared with the control unit.
Figure 40 FSL Zone Wiring - Expander
The allowed values for Alarm Contact/End of Line
resistors are: 4k7/2k2. 1k0/1k0, 2k2/2k2, or
4k7/4k7.
Note: Use the same pair of values for ALL FSL
wired circuits on the control unit. Each wired
expander can use a different pair of resistor
values, but ALL circuits on an expander must
have the SAME values.
Figure 41 shows The wiring connections for FSL
zones on the EXP-WCC.
Figure 41 FSL Zone Wiring
– EXP-WCC
The allowed values for Alarm Contact/End of Line
are the same as for the EXP-W10.
Figure 42 shows the wiring connections for FSL
zones on a KEY-KPZ01. Note that the resistance
values shows are examples.
Figure 42 Wiring FSL Zones on KEY-KPZ01
When programming select the FSL resistor values
for the control unit in
Installer Menu - System
Options - Wired Zone Type
. To select the resistor
values for a wired expander use
Installer Menu –
Detectors Devices – Wired Expanders - Edit Expander
.
If you wish to connect two or more detectors to a
FSL zone, Figure 43 shows the connections
required.
Figure 43 Wiring Two Detectors per Zone FSL.
Figure 44 shows an example of wiring double
doors with two door contacts to one FSL zone.
Each door contact is a reed switch, connected
Zone 0
Zone 1
2K2 EOL
Wired Expander
4K7
Alarm contacts
Tamper contacts
2K2 EOL
4K7
Alarm contacts
Tamper contacts
100 Ohms
Z0
Z1
Z2
Z3
Z4
Zone 0
Zone 1
2K2 EOL
Wired Expander
4K7
Alarm contacts
Tamper contacts
2K2 EOL
4K7
Alarm contacts
Tamper contacts
100 Ohms
KEY-KPZ01
Zone 0
Zone 1
2K2 EOL
4K7
Alarm contacts
Tamper contacts
2K2 EOL
4K7
Alarm contacts
Tamper contacts
100 Ohms