System Options Menu
Page 61
Quick Omit
Yes
– Allows users to omit a zone that is active while the user is setting the system. The
zone must have the Omittable attribute (see page 31).
No
– Users must use the
Omit
menu to omit a zone that is active before they can set the
system.
User Code Reqd
Yes
– After entering the installer code, the system prompts for a user code before allowing
access to the Installer menu.
No
– You can access the Installer menu simply by keying in the installer code.
Note:
If you select this value, the control unit no longer complies with EN50131. This
value complies with PD6662 only if the user has given written consent.
2 Way Replies
Use this option to decide whether the control unit can send status messages to a two-way
remote control unit (FOB-2W-4B).
2W Set Instant
Use this option to specify how a two-way remote control unit (FOB-2W-4B) sets the
system.
Yes
– The partition or system sets instantly when the user operates the FOB-2W-4B.
No
– The partition or system follows the setting mode programmed for it in
Partitions
or
Setting Options
(see page 49).
Duress Enable
Selecting Yes allows master users to assign the Duress user type to users.
A duress code can set and unset the system in the same way as a normal user. However,
each time the code is used, the control unit triggers any output configured as type Duress,
and (if applicable) communicates Duress and Set/Unset events.
Set Status Timeout
This option determines how long the display at the control unit will show the set status.
Selecting Yes causes the display to show the set status for 30 seconds after a set or
unset. Selecting No causes the display to show the set status at all times.
System Status Timeout
This option determines how long the navigation key at the control unit will illuminate after
any key press. Selecting Yes causes the navigation key to illuminate for 30 seconds after
any key press. Selecting No causes the navigation key to illuminate at all times.
User Reset
This option determines under what circumstances a user or the installer can reset the
system after an alarm.
Zone Alarms
This appears when
System Options
– Confirmation – Confirmation Mode
is set to Basic
(page 62).