background image

 
 
 
 
 

HMi

 VU Series Instruction Leaflet 

Specifications 

MODEL 

HMIVU06CUNBE

HMIVU07CUNBE 

HMIVU08CUNBE

HMIVU10WCUNBE

5.6” TFT LCD 

7” TFT LCD 

8” TFT LCD 

10.1” Widescreen 

TFT LCD 

Display Type 

(65536 colors) 

Resolution 

320 x 234 pixels 

800 x 600 pixels 

1024 x 600 pixels 

Backlight 

LED Back Light 

(20,000 hours 

half-life at 25

o

C) 

(Note 1)

 

LED Back Light (10,000 hours half-life at 25

o

C) 

(Note 1)

 

Brightness 
NIT Rating 

200 dc/m

2

 

200 dc/m

2

 

250 dc/m

2

 

200 dc/m

2

 

L

CD MODUL

E

 

Display Size 

113.28 x 

84.70mm 

141 x 105.75mm

162 x 121.5mm 

226 x 128.7mm 

Operation System 

Real Time OS 

MCU 

32-bit RISC Micro-controller 

NOR Flash ROM 

Flash ROM 

8 MB 

(OS System: 

2MB/User 

Application: 6MB)

Flash ROM 128 MB(OS System: 30MB / Backup: 16MB / User 

Application: 82MB) 

SDRAM 

16Mbytes 

64Mbytes 

Backup Memory 

128Kbytes 

16Mbytes 

Buzzer 

Multi-Tone Frequency (2K ~ 4K Hz) / 85dB   

Sound 

Effect 

Output 

AUX 

N/A 

Stereo output 

Ethernet Interface 

N/A 

IEEE 802.3, IEEE 802.3u 

10/100 Mbps 
auto-sensing 

has built-in isolated power circuit

(Note 3)

 

Memory Card 

N/A 

SD Card (supports SDHC) 

USB 

1 USB Host 

(Note 2)

 

Ver 1.1 / 1 USB 

Client Ver 1.1 

1 USB Host 

(Note 2)

 Ver 2.0 / 1 USB Client Ver 1.1 

COM1 

RS-232 (supports hardware flow control) 

COM2 

RS-232 / RS-485

RS-232 / RS-422 / RS-485 

has built-in isolated power circuit 

(Note 3)

 

Serial 

COM Port 

COM3 

RS-422 / RS-485

RS-232 / RS-422 / RS-485 

has built-in isolated power circuit 

(Note 3)

 

EATON CORPORATION

 www.eaton.com   17 

Содержание HMi VU Series

Страница 1: ...tion Leaflet Instruction Leaflet IL04801003E Effective February 2012 Contents Description Page Preface 1 Safety Precautions 1 Installation 3 Wiring 4 Basic Inspection 4 Hardware Features 7 Panel Cut Out 15 Specifications 17 ...

Страница 2: ...t guide may be revised without notice Please consult an authorized distributor or download the most up to date version at www eaton com oi Carefully note and observe the following safety precautions when receiving inspecting installing operating maintaining and troubleshooting The following words DANGER WARNING and STOP are used to mark safety precautions when using Eaton s operator interface Fail...

Страница 3: ...damage to unit Accessing the unit s internal electric assemblies will void the warranty In addition an electrical charge with hazardous voltages may reside in the operator interface after power has been removed for 10 minutes or longer which may result in electrical shock and damage to the unit Turn the power off before changing backup battery and check system settings after changes are made Note ...

Страница 4: ...sent and properly aligned Step 2 Insert fasteners into the operator interface slots All should be finger tight initially Step 3 Torque all fasteners to 6 17lb inch 0 7N M Over torque may cause damage to the operator interface housing Step 4 Maintain a minimum spacing of 60mm from the back of the operator interface ventilation holes fastener 16 16 3 20 4 Units mm Units mm EATON CORPORATION www eato...

Страница 5: ...e to vibration and varying temperatures Ensure that oil water metallic particles or any foreign objects do not fall inside the operator interface ventilation slots and holes as this may cause damage to the unit Ensure the enclosure is free from harmful dust gases and liquids Inspection before system operation power not applied Ensure that all wiring terminals are correctly insulated Visually check...

Страница 6: ...t support RS 422 flow control function HMIVU08CUNBE HMIVU10WCUNBE COM1 Port Supports Flow Control Contact PIN RS 232 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 Note Blank No Connection COM2 Port Supports Flow Control MODE1 MODE2 MODE3 PIN RS 232 RS 422 RS 485 1 TXD D 2 RXD 3 TXD 4 RXD 5 GND GND GND 6 TXD D 7 RTS 8 CTS 9 RXD Note1 Blank No Connection Note2 When COM2 port is used for RS 232 flow control ...

Страница 7: ...XD 3 TXD 4 RXD CTS 5 GND GND GND 6 TXD RTS D 7 8 9 RXD CTS Note1 Blank No Connection Note2 When COM2 port is used for RS 422 with flow control COM3 Port pins 1 4 6 and 9 are used for the signals RTS CTS RTS and CTS as shown in brackets Ethernet Port Contact Ethernet Port PIN Ethernet 1 TX 2 TX 3 RX 4 5 6 RX 7 8 Note Blank No Connection ...

Страница 8: ...HMi VU Series Instruction Leaflet Hardware Features HMIVU06CUNB Front View A B A Power LED Indicator Lights in green when power is applied B Touch Screen Display EATON CORPORATION www eaton com 7 ...

Страница 9: ...w C G B F A E D A Power Input Terminal E USB Host B COM2 and COM3 Note1 F USB Slave C COM1 G System Button D Battery Cover NOTE 1 Refer to the Pin Definition for Communications section for simultaneous use of COM2 and COM3 EATON CORPORATION www eaton com 8 ...

Страница 10: ...HMi VU Series Instruction Leaflet HMIVU07CUNBE Front View A B A Power LED Indicator Lights in green when power is applied B Touch Screen Display EATON CORPORATION www eaton com 9 ...

Страница 11: ...nput Terminal F USB Host B COM2 and COM3 Note1 G USB Slave C COM1 H System Button D Battery Cover I Ethernet Port E Memory Card Slot J Audio Output Port NOTE 1 Refer to the Pin Definition for Communications section for simultaneous use of COM2 and COM3 EATON CORPORATION www eaton com 10 ...

Страница 12: ...ED Indicator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when one of the alarms is on D Touch Screen Display NOTE 1 The function for which the Blue LED indicator lights can be selected in HMiSoft EATON CORPORATION www eaton com 11 ...

Страница 13: ...inal B COM3 Two LED indicate Read or Write status during the communication process C COM2 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Ethernet Port G USB Host H Audio Output Port I Memory Card Slot Battery Cover EATON CORPORATION www eaton com 12 ...

Страница 14: ...icator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when one of the alarms is on D Touch Screen Display A B C NOTE 1 The function for which the Blue LED indicator lights can be selected in HMiSoft EATON CORPORATION www eaton com 13 ...

Страница 15: ... COM2 Two LED indicate Read or Write status during the communication process C COM3 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Ethernet Port G Memory Card Slot Battery Cover H USB Host I Audio Output Port J System Button EATON CORPORATION www eaton com 14 ...

Страница 16: ...struction Leaflet Panel Cut Out HMIVU06CUNB 6 79 172 4 7 24 184 5 67 144 0 063 1 6 0 24 6 5 21 132 4 HMIVU07CUNBE 7 24 184 5 67 144 5 21 132 4 6 79 172 4 0 063 1 6 0 24 6 HMIVU08CUNBE EATON CORPORATION www eaton com 15 ...

Страница 17: ...HMi VU Series Instruction Leaflet 0 063 1 6 0 24 6 8 94 227 1 6 85 174 1 8 64 219 4 6 56 166 5 HMIVU10WCUNBE 10 71 272 7 88 200 0 063 1 6 0 24 6 10 29 261 3 7 45 189 3 EATON CORPORATION www eaton com 16 ...

Страница 18: ...ler NOR Flash ROM Flash ROM 8 MB OS System 2MB User Application 6MB Flash ROM 128 MB OS System 30MB Backup 16MB User Application 82MB SDRAM 16Mbytes 64Mbytes Backup Memory 128Kbytes 16Mbytes Buzzer Multi Tone Frequency 2K 4K Hz 85dB Sound Effect Output AUX N A Stereo output Ethernet Interface N A IEEE 802 3 IEEE 802 3u 10 100 Mbps auto sensing has built in isolated power circuit Note 3 Memory Card...

Страница 19: ... 1 75mm occasional 3 5mm 9Hz f 150Hz continuous 0 5g occa onal 1 0g si X Y Z directions for 10 times Dimensions W x H x D mm 184 x 144 x 50 184 x 144 x 50 227 1 x 174 1 x 61 272 x 200 x 61 Panel Cutout W x H mm 172 4 x 132 4 172 4 x 132 4 219 4 x 166 5 261 3 x 189 3 Weight Approx 670g Approx 800g Approx 1228g Approx 1520g NOTE 1 The half life of backlight is defined as original luminance being red...

Страница 20: ......

Страница 21: ...HMi VU Series Instruction Leaflet ...

Отзывы: