background image

 
 
 
 
 

HMi

 VU Series Instruction Leaflet 

EATON CORPORATION

 www.eaton.com   18

 

MODEL 

HMIVU06CUNB 

HMIVU07CUNBE 

HMIVU08CUNBE

HMIVU10WCUNBE

Perpetual Calendar 

(RTC) 

Built-in 

Cooling Method 

Natural air circulation 

Safety Approval 

CE / UL 

Waterproof Degree 

IP65 / NEMA 4X (indoor use only) 

Operation Voltage 

(Note 4)

 

DC +24V (-10% ~ 

+15%)  

Please use 

isolated power 

supply 

DC +24V (-10% ~ +15%)   

has built-in isolated power circuit 

(Note 3)

 

Voltage Endurance 

AC500V for 1 minute (between charging (DC24 terminal) and FG terminals) 

Power Consumption   

(Note 4)

 

3.0W 

7.68W 

7.8W 

12W 

Backup Battery 

3V lithium battery CR2032 x 1 

Backup Battery Life 

Varies based on temperature and conditions.    Approximately 3 years or more at 25

o

C.

Operation Temp. 

0

o

C ~ 50

o

Storage Temp. 

-20

o

C ~ +60

o

Ambient Humidity 

10% ~ 90% RH [0 ~ 40

o

C], 10% ~ 55% RH [41 ~ 50

o

C] 

Pollution Degree 2 

Vibration Resistance 

IEC 61131-2 Compliant 

5Hz

f

9Hz = continuous: 1.75mm / occasional: 3.5mm 

9Hz

f

150Hz = continuous: 0.5g / occa onal: 1.0g 

si

X, Y, Z directions for 10 times

 

Dimensions 

(W) x (H) x (D) mm 

184 x 144 x 50 

184 x 144 x 50 

227.1 x 174.1 x 

61 

272 x 200 x 61 

Panel Cutout 

(W) x (H) mm 

172.4 x 132.4 

172.4 x 132.4 

219.4 x 166.5 

261.3 x 189.3 

Weight 

Approx. 670g 

Approx. 800g 

Approx. 1228g 

Approx.1520g 

 

NOTE

 

1)  The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving 

current is supplied to 

HMi

. The life of LED backlight shown is an estimated value under 25

o

C normal 

temperature and humidity conditions. 

2)  USB Host port can provide up to 5V/ 500mA of power. 
3)  The withstand voltage of the isolated power circuit is 1500V peak for 1 minute. 
4)  The value of the power consumption indicates the electrical power consumed by 

HMi

 only without 

connecting to any peripheral devices. In order to ensure the normal operation, it is recommended to use a 
power supply which the capacity is 1.5 ~2 times the value of the power consumption.   

5)  For further details, please visit the Eaton websit

www.eaton.com/electrical

.  

Содержание HMi VU Series

Страница 1: ...tion Leaflet Instruction Leaflet IL04801003E Effective February 2012 Contents Description Page Preface 1 Safety Precautions 1 Installation 3 Wiring 4 Basic Inspection 4 Hardware Features 7 Panel Cut Out 15 Specifications 17 ...

Страница 2: ...t guide may be revised without notice Please consult an authorized distributor or download the most up to date version at www eaton com oi Carefully note and observe the following safety precautions when receiving inspecting installing operating maintaining and troubleshooting The following words DANGER WARNING and STOP are used to mark safety precautions when using Eaton s operator interface Fail...

Страница 3: ...damage to unit Accessing the unit s internal electric assemblies will void the warranty In addition an electrical charge with hazardous voltages may reside in the operator interface after power has been removed for 10 minutes or longer which may result in electrical shock and damage to the unit Turn the power off before changing backup battery and check system settings after changes are made Note ...

Страница 4: ...sent and properly aligned Step 2 Insert fasteners into the operator interface slots All should be finger tight initially Step 3 Torque all fasteners to 6 17lb inch 0 7N M Over torque may cause damage to the operator interface housing Step 4 Maintain a minimum spacing of 60mm from the back of the operator interface ventilation holes fastener 16 16 3 20 4 Units mm Units mm EATON CORPORATION www eato...

Страница 5: ...e to vibration and varying temperatures Ensure that oil water metallic particles or any foreign objects do not fall inside the operator interface ventilation slots and holes as this may cause damage to the unit Ensure the enclosure is free from harmful dust gases and liquids Inspection before system operation power not applied Ensure that all wiring terminals are correctly insulated Visually check...

Страница 6: ...t support RS 422 flow control function HMIVU08CUNBE HMIVU10WCUNBE COM1 Port Supports Flow Control Contact PIN RS 232 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 Note Blank No Connection COM2 Port Supports Flow Control MODE1 MODE2 MODE3 PIN RS 232 RS 422 RS 485 1 TXD D 2 RXD 3 TXD 4 RXD 5 GND GND GND 6 TXD D 7 RTS 8 CTS 9 RXD Note1 Blank No Connection Note2 When COM2 port is used for RS 232 flow control ...

Страница 7: ...XD 3 TXD 4 RXD CTS 5 GND GND GND 6 TXD RTS D 7 8 9 RXD CTS Note1 Blank No Connection Note2 When COM2 port is used for RS 422 with flow control COM3 Port pins 1 4 6 and 9 are used for the signals RTS CTS RTS and CTS as shown in brackets Ethernet Port Contact Ethernet Port PIN Ethernet 1 TX 2 TX 3 RX 4 5 6 RX 7 8 Note Blank No Connection ...

Страница 8: ...HMi VU Series Instruction Leaflet Hardware Features HMIVU06CUNB Front View A B A Power LED Indicator Lights in green when power is applied B Touch Screen Display EATON CORPORATION www eaton com 7 ...

Страница 9: ...w C G B F A E D A Power Input Terminal E USB Host B COM2 and COM3 Note1 F USB Slave C COM1 G System Button D Battery Cover NOTE 1 Refer to the Pin Definition for Communications section for simultaneous use of COM2 and COM3 EATON CORPORATION www eaton com 8 ...

Страница 10: ...HMi VU Series Instruction Leaflet HMIVU07CUNBE Front View A B A Power LED Indicator Lights in green when power is applied B Touch Screen Display EATON CORPORATION www eaton com 9 ...

Страница 11: ...nput Terminal F USB Host B COM2 and COM3 Note1 G USB Slave C COM1 H System Button D Battery Cover I Ethernet Port E Memory Card Slot J Audio Output Port NOTE 1 Refer to the Pin Definition for Communications section for simultaneous use of COM2 and COM3 EATON CORPORATION www eaton com 10 ...

Страница 12: ...ED Indicator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when one of the alarms is on D Touch Screen Display NOTE 1 The function for which the Blue LED indicator lights can be selected in HMiSoft EATON CORPORATION www eaton com 11 ...

Страница 13: ...inal B COM3 Two LED indicate Read or Write status during the communication process C COM2 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Ethernet Port G USB Host H Audio Output Port I Memory Card Slot Battery Cover EATON CORPORATION www eaton com 12 ...

Страница 14: ...icator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when one of the alarms is on D Touch Screen Display A B C NOTE 1 The function for which the Blue LED indicator lights can be selected in HMiSoft EATON CORPORATION www eaton com 13 ...

Страница 15: ... COM2 Two LED indicate Read or Write status during the communication process C COM3 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Ethernet Port G Memory Card Slot Battery Cover H USB Host I Audio Output Port J System Button EATON CORPORATION www eaton com 14 ...

Страница 16: ...struction Leaflet Panel Cut Out HMIVU06CUNB 6 79 172 4 7 24 184 5 67 144 0 063 1 6 0 24 6 5 21 132 4 HMIVU07CUNBE 7 24 184 5 67 144 5 21 132 4 6 79 172 4 0 063 1 6 0 24 6 HMIVU08CUNBE EATON CORPORATION www eaton com 15 ...

Страница 17: ...HMi VU Series Instruction Leaflet 0 063 1 6 0 24 6 8 94 227 1 6 85 174 1 8 64 219 4 6 56 166 5 HMIVU10WCUNBE 10 71 272 7 88 200 0 063 1 6 0 24 6 10 29 261 3 7 45 189 3 EATON CORPORATION www eaton com 16 ...

Страница 18: ...ler NOR Flash ROM Flash ROM 8 MB OS System 2MB User Application 6MB Flash ROM 128 MB OS System 30MB Backup 16MB User Application 82MB SDRAM 16Mbytes 64Mbytes Backup Memory 128Kbytes 16Mbytes Buzzer Multi Tone Frequency 2K 4K Hz 85dB Sound Effect Output AUX N A Stereo output Ethernet Interface N A IEEE 802 3 IEEE 802 3u 10 100 Mbps auto sensing has built in isolated power circuit Note 3 Memory Card...

Страница 19: ... 1 75mm occasional 3 5mm 9Hz f 150Hz continuous 0 5g occa onal 1 0g si X Y Z directions for 10 times Dimensions W x H x D mm 184 x 144 x 50 184 x 144 x 50 227 1 x 174 1 x 61 272 x 200 x 61 Panel Cutout W x H mm 172 4 x 132 4 172 4 x 132 4 219 4 x 166 5 261 3 x 189 3 Weight Approx 670g Approx 800g Approx 1228g Approx 1520g NOTE 1 The half life of backlight is defined as original luminance being red...