background image

 
 
 
 
 

HMi Series Instruction Leaflet 

Safety Information 

Preface 

This instruction leaflet will be helpful in 
the installation, wiring and inspection of 
the Eaton 

HM

i

 series of operator 

interface products. Before using the 
product, please read the entire 
document and understand all safety 
precautions before proceeding with 
installation, wiring and operation. 

Carefully note and observe the 
following safety precautions when 
receiving, inspecting, installing, operating, 
maintaining and troubleshooting. The 
following words, WARNING AND 
CAUTION, are used to mark safety 
precautions when using the Eaton 
product. Failure to observe these 
precautions may void the warranty! 

Please observe the following 
precautions:  

Installation 

 

Install the product in a clean and 
dry location free from corrosive 
and flammable gases or liquids. 

 

Ensure that all installation, wiring, 
operation, communication, 
grounding, maintenance, and 
inspection warnings and guidelines 
are followed. 

 

For information on 

HM

i

 software 

installation and operation, please 
refer to the 

HM

i

soft

 user manual. 

 WARNING 

 

Comply with instructions for 
installation. Otherwise it may cause 
equipment damage. 

 

Do not install the product in a 
location that is outside the stated 
specification for    the device. 
Failure to observe this caution may 
result in electric shock, fire or 
personal injury. 

Operation 

For technical support, please contact 
the EatonCare at 877-ETN CARE 
(386-2273) or visit the Eaton website at 
http://www.eaton.com/electrical. 

 WARNING 

 

HM

i

 users must use 

HM

i

soft

 to 

create and edit applications. 

 

Do not modify wiring during 
operation or it may result in electric 
shock or personal   injury. 

 

Never use a hard or pointed object 
to hit or strike the screen because 
doing so may cause damage and 
void the warranty. 

 

 

 

 

 

 

Wiring 

 

 WARNING 

 

Connect the ground terminals to a 
class-3 ground (ground resistance 
should not   exceed 100

). Improper 

grounding may result in electric 
shock or fire. 

 

 

 

EATON CORPORATION

 www.eaton.com   1 

Содержание HMi Series

Страница 1: ...May 2010 Contents Description Page Preface 1 Safety Information 1 General Description 2 Accessories sold Separately 3 Unpack and Inspect 3 Hardware Features 4 Dimensions and Cut Outs 9 Serial Port Pi...

Страница 2: ...grounding maintenance and inspection warnings and guidelines are followed For information on HMi software installation and operation please refer to the HMisoft user manual WARNING Comply with instru...

Страница 3: ...any internal or exposed electrical parts of the device or electrical shock may result Do not remove the operator interface while power is applied or electrical shock may result Wait at least 10 second...

Страница 4: ...cations and application upload download ELC PS01 1 amp 24V DC power supply ELC PS02 2 amp 24V DC power supply HMI SPKIT Spare Parts Kit for HMi Operator Interface HMI04 GASKET 2 Spare Gaskets for 4 HM...

Страница 5: ...A Power Input Terminal B COM2 C COM1 Note D USB E Startup Switch UP position Run Mode DOWN position Boot Menu NOTE For simultaneous communications wire one DB9 connector for COM1 and COM3 according to...

Страница 6: ...er Input Terminal B COM2 Note C COM1 D Battery Cover E USB Host F USB Client G System Key NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout diagram...

Страница 7: ...06CE A Power Input Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM1 F USB NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout dia...

Страница 8: ...ut Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM 1 F USB G Battery Cover NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout di...

Страница 9: ...ut Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM 1 F USB G Battery Cover NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout di...

Страница 10: ...HMi Series Instruction Leaflet Dimensions and Cut Outs 4 HMi HMI04BU HMI04CU 6 HMi HMI06BE HMI06GE HMI06CE HMI06CU EATON CORPORATION www eaton com 9...

Страница 11: ...HMi Series Instruction Leaflet 8 HMi HMI08CE 10 HMi HMI10CE EATON CORPORATION www eaton com 10...

Страница 12: ...232 COM3 Not Used COM3 Used PIN COM1 COM3 COM1 COM3 1 2 RX RX 3 TX TX 4 5 GND GND GND 6 7 RTS TX 8 CTS RX 9 Not Used Note Blank No connection COM2 Pinout for RS 422 RS 485 PIN RS 422 RS 485 G GND GND...

Страница 13: ...COM2 COM3 COM2 COM3 1 2 RX RX 3 TX TX 4 D 5 GND GND GND 6 7 8 9 Not Used D COM2 and COM3 DB 9 Pinout for COM2 and COM3 RS 485 COM3 Not Used COM3 Used PIN COM2 COM3 COM2 COM3 1 D D 2 3 4 D 5 GND GND GN...

Страница 14: ...d PIN COM2 COM3 COM2 COM3 1 2 RX RX 3 TX TX 4 5 GND GND GND 6 7 RTS TX 8 CTS RX 9 Not Used COM2 and COM3 DB 9 Pinout for COM2 and COM3 RS 485 COM3 Not Used COM3 Used PIN COM2 COM3 COM2 COM3 1 RX RX 2...

Страница 15: ...changed from the System menu 6 HMI06BE HMI06GE HMI06CE 8 HMI08CE 10 HMI10CE Recommended wiring Type Wire Gauge AWG Stripped length Torque Solid 28 12 7 8 mm 4 5 lb in Stranded 28 12 7 8 mm 4 5 lb in D...

Страница 16: ...ler 206 4MHz Memory Program History Recipe Alarm Data Register Volatile Non volatile 1M 120K 64K Note 2 4K 64K 1K 3M 120K 64K Note 2 4K 64K 1K 3M 360K 128K 16K 64K 1K 3M 360K 128K 16K 64K 1K Backup Me...

Страница 17: ...7 25 x 5 67 x 1 85 184 1 x 144 1 x 47 Panel Cutout W x H in Inches mm 4 68 x 3 65 118 8 x 92 8 6 79 x 5 21 172 4 x 132 4 Weight in Lbs kg 69 315 62 310 1 69 768 NIT Rating 100 cd m2 300 cd m2 130 cd...

Страница 18: ...ontroller 206 4MHz 32 bit RISC Micro controller 266MHz 32 bit RISC Micro controller 206 4MHz Memory Program History Recipe Alarm Data Register Volatile Non volatile 3M 7M 7M 7M 360K 128K 16K 64K 1K 12...

Страница 19: ...85 184 1 x 144 1 x 47 9 57 x 7 01 x 2 06 243 1 x 178 1 x 52 4 11 70 x 8 74 x 2 01 297 1 x 222 1 x 51 1 Panel Cutout W x H in Inches mm 6 79 x 5 21 172 4 x 132 4 9 11 x 6 55 231 4 x 166 4 11 2 28 3 x 8...

Страница 20: ...HMi Series Instruction Leaflet...