background image

Emergency On Call Service: Local representative (

http://www.eaton.com/moeller/aftersales

or +49 (0) 180 5 223822 (de, en)

3/3

06/11

IL04912002Z

Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Germany

© 2000 by Eaton Industries GmbH,

www.eaton.com/moeller/support

All Rights Reserved

06/11 IL04912002Z

4.459.072.11

Doku

Printed in Germany (06/11)

a

min. Einstellwert

f

R/3 + gewünschter Schwellwert

b

künstl. Nullleiter

a

Min. setting value

f

R/3 + required threshold

b

Artificial zero conductor

a

Valeur de réglage min.

f

R/3 + valeur seuil souhaitée

b

Neutre artificiel

a

Valore di impostazione min.

f

R/3 + valore di attivazione desiderato

b

Messa a terra

a

Valor de respuesta mínimo

f

R/3 + valor de umbral deseado

b

Conductor neutro artificial

a

Löschtaste

b

Prüftaste

a

Delete button

b

Test button

a

Touche d’effacement

b

Touche d’essai

a

Tasto di cancellazione

b

Tasto di verifica

a

Tecla de borrado

b

Tecla de prueba

Ansprechverzögerung in Abhängigkeit des

Isolationswiderstandes bei schneller Änderung

t

d

= 0 s und des eingestellten Ansprechwertes

On-delay depending on the isolation resistance

with small change in t

d

= 0 s and set threshold

value

Retard à l’appel en fonction de la résistance

d’isolement en cas de changement rapide de

t

d

= 0 s et de la valeur d’appel de réglage

Ritardo all’inserzione in base alla resistenza di

isolamento con modifica rapida t

d

= 0 s del

valore di eccitazione impostato

Temporización de trabajo dependiendo de la

resistencia de aislamiento con cambio rápido

t

d

= 0 s y del valor de respuesta establecido

t

A

= Verzögerungszeit

R

im

= Gemessener Isolationswiderstand

R

is

= Eingestellter Isolationswiderstand

t

A

= Delay time

R

im

= Measured isolation resistance

R

is

= Set isolation resistance

t

A

= Temporisation

R

im

= Résistance d’isolement mesurée

R

is

= Résistance d’isolement réglée

t

A

= Tempo di ritardo

R

im

= Resistenza d’isolamento misurata

R

is

= Resistenza d’isolamento impostata

t

A

= Tiempo de retardo

R

im

= Resistencia de aislamiento medido

R

is

= Resistencia de aislamiento

establecido

A1

A2

L

L2

220 – 415 V

L1

L3

~

EMR4-

RAC...

N

A1

A2

L

L1

110 – 240 V, 1~

N

~

EMR4-

RAC...

A1

A2

L

L2

380 – 415 V

L1

L3

*380 V: R = 68 kΩ (5 W)

400 V: R = 75 kΩ (5 W)

415 V: R = 82 kΩ (5 W)

~

a

b

EMR4-

RAC...

A1

A2

L

L2

220 – 240 V

L1

L3

~

EMR4-

RAC...

A1 15 S1 S2

16 18

L

A2

15

L

R <

18

16

A1

A2

a b

L

N

PE

A1 15 S1 S2

16 18

L

A2

15

L

R <

18

16

A1

A2

a b

L2

L1

L3

N

3

2.5

2

1.5

1

0.5

0.1

1

10

100

[sec]

[k

O

]

100

1

2

4

6

10

20

40 60

[k

O

]

Rim

RiS

t A

109.5 mm

(4.31”)

102 mm

(4.02”)

78

mm

(3.07”)

5.5 mm

(0.22”)

1 mm

(0.04”)

100 mm

(3.94”)

45 mm

(1.77”)