Eaton Electro-hydraulic Fan Drive System Скачать руководство пользователя страница 4

4

Eaton  

Electro-hydraulic Fan Drive System  E-SYFD-MROO1-E3  October 2008

Electronic 

Controller 

Options

TCA Electronic Controller 

The TCA at the heart of the 

EH Fan Drive System, is a 

rugged, fully encapsulated 

digitally programmable con-

troller specially designed for 

mobile environments.

It is prepared for CANbus 

communications on a ve-

hicle network. Software for 

controlling the EH Fan Drive 

System is loaded in the con-

troller memory at the factory. 

Control software parameters 

are adjusted via RS 232 hook-

up to a laptop computer.

The TCA controller is available 

for both 12 V or 24 V vehicle 

power systems. With 5 con-

figurable inputs and 2 Pulse 

Width Modulated (PWM) 

outputs, the TCA can inter

-

face with a variety of system 

components and drive up to 

two electro-hydraulic valves.

Two Channel Amplifier (TCA)

EFX Electronic Controller 

Eaton EFX electronic control-

lers and I/O modules provide 

a full range of electronic con-

trols. With an array of control-

ler options and I/O modules, 

an EFX system can address 

any application need. All EFX 

products are IP67 rated and 

are built for harsh mobile 

and industrial application 

environments. The EFX line is 

programmed and configured 

using Eaton CONTROL F(x)™ 

software.

Applications

Excavators, forestry, 

 

telehandlers, utility vehicles, 

cranes, ag machinery, paving

Specifications

Four different EFX controllers 

and 3 I/O expansion modules 

provide analog, digital, and 

frequency inputs as well as 

digital, PWM, and current-

controlled outputs. Each EFX 

controller has both CANopen 

and J1939 interfaces.

EF(x) Controllers

Fan Drive  

Configuration

Power Requirement

• 12 VDC or 24 VDC

Laptop or PC  

Communication

•   RS232 for 

 

communication with GUI

Inputs

•  Five user configurable 

inputs

  – Two Thermistor inputs
  –  Two Digital or Switch 

inputs

  –  Engine Control  

Module cooling 

 

command voltage 

signal

Or

• Optional CANbus signal

Outputs

•  PWM current 

 

controlled driver for  

proportional flow control

•  On-off driver for fan

 

off or fan reverse

Mechanical

• Polymer enclosure
•  Fully encapsulated 

 

electronics

•  Flying lead harness 

 

with 10-pin MetriPak 

 

connector

•  Two Mounting flanges: 

#8 fasteners

•  Dual color LED for 

 

status and diagnosis

Environment

•  Operating temperature: 

-40°C to +85°C

•  Meets EMC standards 

 

off-road vehicle

•  Reverse battery and load 

dump protection

•  Input/output short circuit 

protection

• UV resistant
•  Water: temporary 

 

immersion

•  Random vibration 

 

5.8 Grms

• Shock: 50 G

Содержание Electro-hydraulic Fan Drive System

Страница 1: ...Electro hydraulic Fan Drive System Efficient cooling power where you need it...

Страница 2: ...arge air temperature can help reduce engine emissions Improvement in fuel economy Increased power output Choice of variable or fixed displacement systems Eaton can be your single source for fan drive...

Страница 3: ...ol accuracy of fan speed by eliminating temperature effects on proportional valve coil Buses Modulates fan speed Reduces operating power and noise Limits fan speed on start up Reduces fan power draw o...

Страница 4: ...h mobile and industrial application environments The EFX line is programmed and configured using Eaton CONTROL F x software Applications Excavators forestry telehandlers utility vehicles cranes ag mac...

Страница 5: ...graphically monitored and saved to verify actual results When the cooling logic is fully defined resulting parameters are saved and used for exact system duplication for your production application S...

Страница 6: ...lution amplifies and conditions the ECM signal to be used on a hydraulic circuit A fixed displacement pump fan drive system is suited for a smaller and simpler cooling system A fixed displacement pump...

Страница 7: ...based on a temperature sensor and digital inputs to the TCA A variable displacement pump fan drive system is suited for larger and more complex cooling systems A variable displacement pump reduces the...

Страница 8: ...for maximum efficiency directs more flow and input energy to the work not to heat and waste Vane Hydraulically balanced design increases the operating life of the bushing bearing by eliminating side l...

Страница 9: ...or Fixed displacement 83 cc 74600 Series Filter Return line filter 57 L min 95 L min 227 L min OFRS 25 Gear Motor Fixed displacement 50 cc 100 Series Piston Motor Fixed displacement 33 49 cc 74300 Ser...

Страница 10: ...d from the operator s joystick to an electro hydrau lic directional control valve Other work circuit applica tions include control of aux iliary motors power take off clutches and transmissions Additi...

Страница 11: ...n Vickers Weatherhead Eaton is a global diversified industrial manufacturer Eaton is a leader in Fluid power systems Electrical power quality distribution and control Automotive engine air management...

Страница 12: ...ic 11th Floor Hong Kong New World Tower 300 Huaihai Zhong Road Shanghai 200021 China Tel 86 21 6387 9988 Fax 86 21 6335 3912 2008 Eaton Corporation All Rights Reserved Printed in USA Document No E SYF...

Отзывы: