Commissioning
80
02/16 MN05013001Z EN
If the easySafety devices without a display do not contain an
safety circuit diagram, but this is stored on the memory card,
this is loaded automatically after startup. The device will
then process the circuit diagram in RUN mode.
j
Danger!
In RUN mode an easySafety device will immediately run
the saved safety and standard circuit diagram in the unit
when the power supply is switched on.
The outputs are activated according to the switch logic of
the circuit diagram.
Configure your machine/plant so that the automatic
starting of the easySafety device never causes
unintentional starting of the machine/plant concerned.
Create your safety circuit diagram so that after the power
supply is switched on, there is always a defined safety
startup behaviour. Information on startup behaviour is
provided on page 592.
The device does not start with RUN mode if you deactivate
RUN MODE (exception: devices without display).
easySafety devices without display and operator buttons
have a different startup behaviour. The RUN MODE and
CARD START functions are activated automatically in this
case, since no device operations for manual starting are
possible.