Displaying device information
631
02/16 MN05013001Z EN
Displaying device informa-
tion
The device information is provided for service tasks or in
order to determine the performance level of the device.
This function is only available with devices featuring a
display.
X
Switch to the main menu and use the cursor button
Í
or
Ú
to move to the INFORMATION menu.
X
Press OK.
This will display all device information:
Line 1: shows a program name of max. 16 characters. This
can be entered separately for each device under Name in the
Information tab in Project View. Line 1 will remain empty if
this name is not entered.
Line 2: always shows the date/time of the last change to the
safety configuration. Independently of whether the change
was made in easySoft-Safety or locally with the easySafety
device's operator buttons. In the case of a local change, the
version is shown as V0000.
Line 3: Shows the check sum of the configuration in the
device as a four digit hexadecimal value with CRC xxxx.
Vxxxx shows as four-digit hexadecimal number the version
of the configuration created and managed in easySoft-
Safety. The display will always show V0000 if you are
entering and storing the safety circuit diagram locally via the
operator buttons of the easySafety device.
Line 4: shows the result of the hardware detection (power
supply, interfaces, I/O type etc.
• DC/AC
– AC (AC voltage)
– or DC (DC voltage).
• TRN/R N
– T: Transistor output,
STOP
å
RUN
Æ
SET CLOCK
MODE
INFORMATION...
æ
SAFETY...
STANDARD...
Safety_Test_APP
l
22.12.2007 17:07
CRC 9031 V0001
DC TRN
æ
OS-VER 1.10.58
OS-CRC 2177