OPERATING HEAD POSITIONING

Heads can be mounted on the switch body in any of four
directions, 90° apart. Torque screws according to require-
ments on page 1.

OPERATING HEADS — SIDE ROTARY

The operating mode (CW, CCW or CW and CCW) of these
spring return operating heads is easily changed without
tools as shown in the illustration. Remove the head from
switch body. Pull out the plunger and turn until its position
matches that shown on the diagram for the desired opera-
tion mode. Levers are adjustable to any angle (360°). The
operating shaft screwdriver slot can be used to maintain
shaft position during lever installation.

Side Rotary Operational Head

Bottom View of Side Operated

Rotary Head (Note Mode Change

Instructions in Head)

Set Operating Head Mode

Before Assembly

Push Operational Head

OPERATING HEADS — WOBBLE STICK

These spring return, top operated heads use different rod-
type operators to detect motion in any direction perpendicu-
lar to the operator. The operator screws onto the threaded
head stub.

TORQUE REQUIREMENTS FOR LIMIT SWITCH ASSEMBLY

Tighten the operating head screws to a torque value within the
following ranges to ensure and maintain the Enclosure Type
Ratings for the assembled limit switch.

Operating Head Screws — Tighten to ensure contact of head
to switch body: 14 - 18 lb. in.

OPERATING HEADS — PUSH OPERATED

These spring return top push or side push operating heads
are available in pushbutton and roller styles.

The push roller style can be converted from vertical to
horizontal operation or vice versa. Pull roller out of the head
until it can be rotated 90° to the desired orientation. When
released, it will snap into the  set position.

The Maintained Contact head has the reset pushbutton
located opposite of the actuator pushbutton.

Содержание DeviceNet E50DNA

Страница 1: ...y and longest life expect ancy for Industrial Limit Switches INSTALLATION WARNING DO NOT INSTALL OR PERFORM MAINTENANCE ON THIS DEVICE WHILE THE CONTROLLER IS ENERGIZED DEATH OR SEVERE PERSONAL INJURY...

Страница 2: ...embly Push Operational Head OPERATING HEADS WOBBLE STICK These spring return top operated heads use different rod type operators to detect motion in any direction perpendicu lar to the operator The op...

Страница 3: ...030 in 0 290 in 4 lbs 8 oz B E50DS3 0 200 in 0 130 in 0 320 in 5 lbs 5 lbs B E50DH1 0 040 in 0 020 in 0 280 in 4 lbs 8 oz C E50DT1 0 040 in 0 020 in 0 280 in 4 lbs 8 oz C E50DT2 0 040 in 0 020 in 0 2...

Страница 4: ...er Netview configuration software is a function to locate nodes by continually flashing the Module Network Status LED between green and red Once the Netview configuration software is communicating to...

Страница 5: ...n line but not allocated Green by a master Flashing Device has detected a recoverable fault or a connection Red is in the timed out state Solid Device has detected an unrecoverable fault or is in the...

Страница 6: ...de Rotary Operator Top Pushbutton Side Push Operators Top Pushbutton Adjustable Side Pushbutton Maintained Top Pushbutton Adjustable Side Pushbutton Side Push Roller 1 1 1 Can accommodate both U S 29...

Страница 7: ...Switch state represents the physical location of the limit switch Head Actuation Count increments each time the head is actuated When Head Actuation Count reaches 80 or 100 of the Max Head Actuation C...

Страница 8: ...s UINT Timestamp UINT Test Object Class 199 C7HEX Instance 1 Attribute Attribute ID Access Power OK 5 Get LED Disable 6 Get Set SOFTWARE TIMING The E50 is not capable of responding to all DeviceNet me...

Отзывы: