tilt the detector by 9° to achieve similar coverage 

to Figure 1 (although sensitivity will be reduced).

-2° tilt, lens masked, and 

creep mirror removed

Mask this 

area of lens

Figure 2.  Coverage for pet tolerance

45° tilt and lens 

masked

Mask this 

area of lens

Figure 3.  Coverage for short-range surveillance

Beam Patterns

Figure 4 shows the beam pattern (with 0° tilt).

Detector programmed 

for max range (default)

Detector programmed 

for min range

Figure 4.  Beam patterns

Step 2: Mount backplate

Note: During installation, protect the electronics 

against water to avoid damage.

1.  Using the template provided, drill the wall 

to accept the three fixing screws and the 

tamper foot cup (Figure 5).

  

Tamper foot

  

Tamper foot cup

 

Backplate

Figure 5.  Tamper foot and cup

Note: Two extra tamper feet are provided; 

each has a different shaft length to allow for 

different wall surfaces. You can prise off the 

existing foot using a small screwdriver.

2.  Remove the front cover as follows:

a.  Loosen the locking screw on the front of 

the cover. 

b.  On each side of the mounting base, 

insert the opening tool into the slot and 

twist to separate the cover from the 

mounting base. 

c.  Remove the cover (the cover hinges 

from the top).

3.  Remove the 3 securing screws located along 

the top edge of the detector assembly, and 

remove the assembly from the backplate. Put 

the loose back-tamper spring to one side.

4.  Screw the backplate to the wall (screw 

through the thin areas of plastic on the 

mounting base). Make sure the tamper foot 

engages correctly into the cup.

Step 3: Add/configure detector

1.  Fit the batteries. Observe correct polarity: 

large “+” and “–” symbols are marked on 

the PCB. 

2.  Use the relevant Installer options at the 

control unit to:
a.  Learn a new radio detector (when 

prompted, activate one of the tamper 

switches at the detector).

b.  Program the zone as required.

For further information, please refer the 

Engineering Guide.

3.  Remain in the Installer menu (while the cover 

of the detector is off). 

4.  If required, use the local programming 

options to configure the range or pulse count 

(see “Local programming options”).

Step 4: Refit and align detector

1.  Fit the back-tamper spring in place, then 

secure the detector assembly to the 

backplate with the 3 screws.

2.  Align the detector by rotating and/or tilting 

the detector assembly by hand as required.

If required, apply masking to mask areas you 

do not want to monitor (see “Masking”).

If pet tolerance is needed, remove the 

batteries, then use a pair of long-nose pliers 

to remove the metal creep mirror (Figure 7). 

Refit the batteries.

Содержание DET-REXT-PIR30

Страница 1: ...gure the device before mounting it This product must be installed by qualified service personnel Installing the unit Step 1 Choose location The PIR detects changes in heat and movement therefore items such as trees shrubs ponds boiler flues air conditioning units and animals should be considered The sensor is more sensitive to movement across the beams than to movement directly towards or away fro...

Страница 2: ... the cover hinges from the top 3 Remove the 3 securing screws located along the top edge of the detector assembly and remove the assembly from the backplate Put the loose back tamper spring to one side 4 Screw the backplate to the wall screw through the thin areas of plastic on the mounting base Make sure the tamper foot engages correctly into the cup Step 3 Add configure detector 1 Fit the batter...

Страница 3: ...e the lens by hand from the front Do not use tools 3 Cut portions from the sticker and apply them to the rear smooth side of the lens 4 Refit the lens making sure it is fitted correctly into the frames and the correct way up the top of the lens has a small notch CAUTION Do not put pressure on the wireless PCB otherwise damage may result Local programming options You can program the settings shown ...

Страница 4: ...14 53 EU The full text of the EU declaration of conformity is available at the following internet address www touchpoint online com The information recommendations descriptions and safety notations in this document are based on Eaton Corporation s Eaton experience and judgment and may not cover all contingencies If further information is required an Eaton sales office should be consulted Sale of t...

Отзывы: