background image

47556, Revision D 

 

MAINTENANCE 

To service unit: Isolate it from the process air and electric supply 
using proper lockout tagout plant procedures. De-pressurize and de-
energize all sources of power. 

 

Disconnect all remote airlines running to the assembly, marking 
all airlines before removing. Loosen the 4 swing bolts from the 
lid and remove the lid assembly with cleaning disc attached. 

 

Inspect cleaning disc for excessive wear.  If replacement is 
required see the spare parts drawing supplied with the unit and 
select the appropriate repair kit or contact Ronningen-Petter 
Customer Service. Refer to instructions included with disc 
repair kit. 

 

Remove element by using the element removal handle 
supplied with the unit (see the drawing below). Inspect element 
for damage and plugging. Clean or replace as needed. 
Remove lower “O” ring and clean.  

 

To reassemble, flush housing removing all dirt and 
contaminant. Clean and inspect all “O” rings for damage, 
replace as needed. Place lower “O” ring in the bottom of the 
housing making sure it lays flat and is centered on the ID of the 
housing (Attach top element “O” ring as needed.) Replace 
clean element in the housing with the handles up.  

 

 

To replace the lid and cleaning disc assembly, extend the 
center shaft to allow compression of the cleaning disc with the 
compression pliers supplied with the unit. Place the Lid “O” ring 
on the upper body flange checking to see that it is laying flat 
and centered on the housing. Insert the cleaning disc in the 

element and release the pliers and seat the lid double-checking 
the placement of the lid “O” ring. Replace the lid bolts and 
tighten. 

 

Reconnect the airlines 

 

Place the system back online using proper plant procedures. 

 
For maintenance of other items such as lid seals, actuators, and 
valves, see instructions supplied with repair kits. 
 

EATON Filtration, LLC 

9151 Shaver Road 

Portage, Michigan  49024-6798 USA 

Phone (Worldwide) +1 269 323 1313 

Phone (U.S.) +1 800 656 3344 

Fax +1 269 323 2403 

Email [email protected] 

www.filtration.eaton.com 

 

 

SEALS

45695

45696

45697

ELEMENT

45693

EPT

45803

O-RINGS

45801

45802

VIT

BUN

MAT'L

LID

45691

45692

ELEMENT

BUN
VIT
EPT

BUNA
VITON
EPT

0.001"

63088

63063

63062

63061

63060

63067

63066

63065

63064

63077

0.015"

0.045"

0.030"

0.024"

0.0015"

0.009"

0.003"

0.004"

0.006"

0.002"

63087

P/N

DEFINED PORE SIZES

RETENTION

750

0.030"

45778

6250

3125

1550

(MICRON)

1125

PERFORATED ELEMENT SIZES

0.125"

42670

0.250"

42663

0.045"

RETENTION

0.062"

42662

P/N

45780

15

0.0006"

45771

100

25

75

50

38

380

610

200

175

230

150

0.006"

45776

0.009"

0.007"

0.008"

0.024"

0.015"

45777

47339

46261

45779

45789

0.0015"

0.002"

0.003"

0.001"

0.004"

45773

45774

45775

40667

45772

(MICRON)

SLOTTED ELEMENT SIZES

RETENTION

P/N

BUN, VIT, EPT

SLOTTED OR

PERFORATED

DEFINED PORE

(MICRON)

75

100

150

230

380

610

760

1140

38

25

50

TFE

*N/A

*N/A

*N/A

BUNA
VITON
EPT

ASSY

CLEANING DISC

KYNAR

46743

URETHANE

46608

TFE

MAT'L

UHMWPE

46741

46742

46681

40706

46680

46744

REP. KIT