Operations and Maintenance Manual 

for Eaton Pressure Filters, Change-Over 
DA/EDA 103,253,403,633,1003, related specification 

Sheet No. 

67630-4D 

 

Page 1/4 

 

 

 

 

This manual contains operation and maintenance information for series DA/EDA 103, 253, 403, 
633, 1003 and related specifications. For customer specific models, there are additional instructions 
on those data sheets. The pressure filters listed above are intended for the filtering of liquid media.

 

 

1. Safety instructions 

 

WARNING: Avoid injury. Read and understand this manual before operating the filter.

 

FAILURE  TO  FOLLOW  THIS  WARNING  COULD  LEAD  TO  DEATH,  SEVERE  INJURY, 
OR PROPERTY DAMAGE

. Eaton does not assume liability for any damage that occurs to 

due misuse of equipment. 

 

 

 

WARNING:

 

This  filter  is  a  pressure  vessel  designed  to  operate  under  specific 

pressure,  temperature,  and  other  engineering  parameters.

  Follow  the  operating 

conditions specified on each data sheet. Operating outside of these parameters can cause 
damage  to  important  pressure  holding  parts  and  sealing.  Pay  special  attention  to  excess 
pressure, temperature range, and operating fluid. The compatibility of filter components with 
the  operating  fluid  should  always  be  considered  before  operation. 

USE  OF 

INCOMPATIBLE  MATERIALS  COULD  LEAD  TO  PRODUCT  FAILURE,  LEAKAGE, 
DEATH, SEVERE INJURY OR PROPERTY DAMAGE. 

 

 

 
 
 
 

 

 
 

WARNING: Always wear safety goggles and gloves when working on the filter.

 Under 

working conditions, the filter housing is pressurized. Do not try to loosen or remove any part 
of  the  filter  or  the  filter  housing  during  operation.  The  operating  fluid  could  escape  at  high 
pressure and high temperatures. This does not apply to the offline vessel that is not under 
operation. 

FAILURE TO FOLLOW THIS WARNING  COULD LEAD TO DEATH, SEVERE 

INJURY, OR PROPERTY DAMAGE. 
 
WARNING: Leaking operating fluid can cause injury and burns. Equipment should be 
shut  down  and  isolated  from  energy  sources  and  other  equipment  before  any 
inspection or servicing to prevent risk of shock or process fluid leakage. 

Do not open 

the filter housing until you make sure it is not pressurized. The filter surface may be hot and 
cause  burns.  When  changing  the  filter,  check  the  operating  temperature  before  touching 
any surface during operation. If you come into contact with the operating fluid, please follow 
the  safety  instructions  provided  by  the  fluid  manufacturer. 

FAILURE  TO  FOLLOW  THIS 

WARNING COULD LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE. 

 

To ensure proper fit and function, only use Eaton spare parts. 

 

2. Installation 

The  filter  is  supplied  and  delivered  ready  to  be  installed.  The  mounting  position  of  the  filter  is  vertical. 
The  filter  has  to  be  fitted  with  fastening  screws  in  size  and  amount  according  to  the  corresponding 
fastening bore holes of the filter housings. The filter should be mounted to minimize tensile forces on the 
filter housing and change-over valve. The piping should be connected with flanges. 
 
During installation ensure that: 
 

-

 

No dirt and no impurities of foreign fluids penetrate the filter. 

-

 

The connections for input and output are correctly attached to the pipe system. 

-

 

The pipe system is connected to the filter to minimize stress on the filter. 

-

 

Ensure the filter element is accessible for service and change out. 
 

Clogging indicators should be installed according to the instructions on the unit specific data sheet and 
the instructions in this manual.

 

 

 

 

 

 

 

Содержание DA/EDA 103

Страница 1: ... pressure and high temperatures This does not apply to the offline vessel that is not under operation FAILURE TO FOLLOW THIS WARNING COULD LEAD TO DEATH SEVERE INJURY OR PROPERTY DAMAGE WARNING Leaking operating fluid can cause injury and burns Equipment should be shut down and isolated from energy sources and other equipment before any inspection or servicing to prevent risk of shock or process f...

Страница 2: ...tion 3 Fill both sides of the filter housing at the regular operating fluid flow 4 Open the air bleed screws or connections Connect tubes that lead to a drain pan air bleed connection information can be found on data sheet 1659 5 Allow the operating fluid to drain reduce volume flow from 10 to 50 l min 2 6 to 13 2 GPM until it is bubble free and flows out of both air bleeding tubes 6 Shut off appl...

Страница 3: ...r lid back onto the filter housing and tighten the screw plugs The screws need to be tightened in an X pattern Recommended tightening torques listed in the table below Type DA EDA 103 DA EDA 253 403 DA EDA 633 1003 Screw M10 M12 M16 Torque Nm lbf ft 45 50 33 37 65 70 48 52 125 130 92 96 11 Close the drain plugs 12 Open the pressure balance valve until operating fluid flows out of the air bleed con...

Страница 4: ...e effects of such use or the results to be obtained Eaton assumes no liability arising out of the use by others of such products Nor is the information herein to be construed as absolutely complete since additional information may be necessary or desirable when particular or exceptional conditions or circumstances exist or because of applicable laws or government regulations EN 11 2019 6 Pressure ...

Отзывы: