PROGRAMMING FUNCTION CODES
To change the operation of a function with the
PROGRAM INHIBIT jumper removed, follow these
steps:
1. Press the “FUNCTION” key. The display
blanks indicating that the key has been
pressed.
2. Select the one or two digit function code for
the desired function. For example, press “30”
to select the relay and transistor timeout value.
The display indicates the two digits pressed for
the function code. If more than two digits are
pressed, the display only retains the last two
digit entries.
3. Press the “ENTER” key. The current value for
the specified function is displayed. If the value
does not need to be changed, a new function
may be chosen by returning to step 1. The
“COUNT” key may also be pressed to return to
the count value.
4. Press the digit keys for the desired entry.
Using the above example, a value of 100 could
be entered to select 1.00 second of timeout.
The display shows the value as the keys are
pressed.
COMMUNICATING TYPE
(Continued)
(Model 5886-1400 only)
5
6
7
“X” Value
*0
1
2
3
Count
Preset 1
Preset2
✓
✓
No Transmission of Count, Preset 1, or Preset
2.
Preset 3
Scale Factor
✓
No Transmission of Preset 3 or Scale Factor.
✓
✓
✓
PRINT ON RESET
92
*0
1
No Print on Reset. Print when Print Request
input is energized or Print Request
communication (ASCII”?”) is received.
Print on Reset. Print when Reset input is
energized. Then automatically reset. No counts
are lost with the Print on Reset option.
OUTPUT 1 COINCIDENCE
VALUE
96
—
Shows the coincidence value for Output 1.
When in the Prewarn mode, this value may be
different than Preset 1.
OUTPUT 2 COINCIDENCE
VALUE
97
—
Shows the coincidence value for Output 2.
When in the Prewarn mode, this value may be
different than Preset 2.
SELF-DIAGNOSTIC MODE
40
*0
1
Return to normal operation.
Preform self-diagnostics. Returns to “0” upon
successful completion.
SELECT FACTORY-SET
PARAMETERS
43
*0
1
Return to normal operation.
Reset all function codes to the factory set
values.
FUNCTION
FUNCTION
CODE
ENTRY
CHOICES
DESCRIPTION
NOTE: Choices shown with asterisks are the factory set values
Figure 21.