background image

 

DOCUMENT 1136 

REV. G 

Instruction Manual 

Pro APF Series LED 

ICAO TCL, IHP, & STP 

 

11 

 

IMPORTANT 

 

The jumpers must be placed in the correct position(s) for proper 

operation of the appropriate fixture. 

The heater will remain on indefinitely with the temperature sensor 

disconnected. 

Apply thermal grease to the mating surface of the new power supply and secure it to the bracket using the three 
supplied screws. Torque the screws to 2.49-2.71 N-m (22-24 in-lb). Secure the power supply bracket. Using #10 
2-piece lock washers, torque the bracket mounting screws to 2.8-3.4 N-m (25-30 in-lb).  
 
For P2 and B1 light units, the top power supply must be removed before the power supply bracket can be 
removed. Discard the top power supply as an electronics assembly. After removing and installing the bottom 
power supply and mounting bracket. Configure the jumper settings for the new power supply per Table 1. 
Reconnect internal cables per appropriate wiring diagram, Figures 11 through 14.

 

 

 

 

 

IMPORTANT: 

IMPORTANT 

 

The jumpers must be placed in the correct position(s) for proper 

operation of the appropriate fixture. 

 

The heater will remain on indefinitely with the temperature sensor 

disconnected. 

 

Apply thermal grease to mating surface of the power supply and fasten it to the power supply bracket. Torque the 
top power supply’s screws to 2.49-2.71 N-m (22-24 in-lb). Reconnect the power supply(ies) to the feed-through 
terminal(s) and LED assembly(ies) and arctic kit(s), if applicable. Inspect/replace the optical housing’s o-ring 
per paragraph 9.3.

 

Assemble the inner cover onto the optical housing. The screw-hole patterns on the inner 

cover and optical housing are offset to insure proper alignment. Torque the mounting screws to 2.8-3.4 N-
m (25-30 in-lb). Perform a pressure test per paragraph 9.6. Connect the light unit lead(s) to the isolation 
transformer(s)

Clean the mounting flange area of the light base. Place the optical assembly into the light 

base. Torque bolts per section 8.4. 

 

 

9.8        Optional External Gasket Replacement 

 

Every time an optical assembly with the optional external gasket is removed from the light base, the gasket 
on the outside surface of the inner cover should be examined and replaced if necessary. Refer to section 10 
to determine the appropriate replacement kit for your light unit. Any gasket that is stretched, torn, has a 
permanent set or some other defect, will allow water to enter the light base. Remove the old gasket from the 
inner cover by carefully scraping with a plastic, or comparably soft, tool. Take care not to damage the inner 
cover. Form a thin bead of high temperature silicone adhesive, such as GE RTV 106, on the inner cover 
sealing surface. Position the new gasket on the inner cover in the same location as the old gasket. Apply a 
thin coat of Dow Corning FS 1292 grease over the entire outside surface of the gasket before placing the 
optical assembly on the light base. Torque bolts per section 8.4. 
 

 

9.9        Cleanliness and Workmanship 

 

Service life depends upon the entire assembly being waterproof.  All surfaces must be clean, dry and free of 
all foreign matter if the light unit is to operate for extended periods without requiring maintenance. 

 

Содержание CROUSE-HINDS PRO APF Series

Страница 1: ...ight TCL ICAO Intermediate Hold Position Light IHP ICAO Stop Bar Light STP ICAO ANNEX 14 Third Edition Figure A2 12 Through A2 16 IEC TS 61827 2004 EATON Crouse Hinds Series 1200 Kennedy Road Windsor...

Страница 2: ...ABLE 1 WITH REVISED JUMPER SETTINGS ADDED DANGER WARNINGS TO SECTIONS 4 AND 4 1 ADDED SECTIONS 8 3 AND 8 4 KF CS D A215 039 REVISE COPYWRITE NOTE ADD 2 PIECE LOCKWASHER TO SECTION 7 DELETE POLYURETHAN...

Страница 3: ...TP iii 2 Product Warranty Warranty Refer to Eaton s Crouse Hinds Airport Lighting Products Terms and Conditions for product specific warranty information Refer to Cooper Crouse Hinds Airport Lighting...

Страница 4: ...r unsafe practice will result in severe injury or death WARNING WARNING The hazard or unsafe practice could result in severe injury or death CAUTION CAUTION The hazard or unsafe practice could result...

Страница 5: ...safety precautions have been incorporated in this equipment the following rules must be strictly observed DANGER 4 1 Keep Away from Live Circuits Operating and maintenance personnel must at all times...

Страница 6: ...8 2 Installation of a Light Unit 4 8 3 Toeing Figures 5 8 4 Metric Installation Bolt Torque Method 6 8 5 Heico Lock Installation Guidelines 7 9 Maintenance 7 9 1 Cleaning Lenses 7 9 2 Light Module Rep...

Страница 7: ...DOCUMENT 1136 REV G Instruction Manual Pro APF Series LED ICAO TCL IHP STP 1 6 Part Number Explanation ICAO TCL IHP STP...

Страница 8: ...DOCUMENT 1136 REV G Instruction Manual Pro APF Series LED ICAO TCL IHP STP 2...

Страница 9: ...ght emitting lenses are held into the optical housing with a bracket gasket and elastomeric boot All IHPs all STPs and one plug P1 TCLs have one power supply fastened to the inner cover Two plug P2 op...

Страница 10: ...ng flange and gasket sealing surfaces on the light base are clean Coat the optional gasket on the inner cover with Dow Corning FS 1292 grease Connect the plug s from the light unit to the secondary ie...

Страница 11: ...ght beam that is angled with respect to the alignment of the light fixture Refer to the product options in Section 6 to determine if your light unit is straight toed or curved The figures below show t...

Страница 12: ...commended as installation tools Check torque re torque all bolts within 2 weeks of initial installation Maintain all bolts by checking torque and re torqueing per FAA specifications If other lubricant...

Страница 13: ...field servicing be limited to bolt torque checks per section 9 10 4 and cleaning the lens as described in section 9 1 For extensive field service refer to sections 9 and 10 for instructions and spare...

Страница 14: ...lb Perform a pressure test as described in paragraph 9 6 Connect the light unit lead s from the isolation transformer s Clean the mounting flange area of the light base Place the light unit into the...

Страница 15: ...ly in the lens opening and press it into place Verify that the lens boot is not pinched in the lens opening Using a new lens retaining gasket fasten the lens retaining bracket and heater tie down scre...

Страница 16: ...sed Once the pressure test is complete be sure to relieve the air pressure 9 7 Power Supply Replacement CAUTION CAUTION Power supply is hot when light unit is energized and remains hot for a short tim...

Страница 17: ...ical housing s o ring per paragraph 9 3 Assemble the inner cover onto the optical housing The screw hole patterns on the inner cover and optical housing are offset to insure proper alignment Torque th...

Страница 18: ...only if practical Whenever snowplows must traverse in pavement light units they should be traveling at less than 5 mph or have the blades lifted clear of the units Recommended snow removal techniques...

Страница 19: ...21644 1 8 TCL IHP STP ICAO Fig A2 12 13 15 Arctic Kit Replacement Kit 13 21644 2 8 TCL IHP STP ICAO Fig A2 14 16 Arctic Kit Replacement Kit Power Supply Replacements 14 21645 1 Power Supply Replaceme...

Страница 20: ...e can while the fixture is powered Dangerous voltage may be present on the primary and secondary sides of the isolation transformer Contact Crouse Hinds Airport Lighting for assistance prior to operat...

Страница 21: ...5W isolation transformer or a voltage limited constant DC current source be used to test failed fixtures to limit the input voltage A buzzing or humming noise coming from the isolation transformer may...

Страница 22: ...ng jumpers o See Table 1 for proper jumper setting More than 25 of the driven LED Shorted o Replace LED module per section 9 2 Figure 3 Power Supply Status LED Location If the status LED is not visibl...

Страница 23: ...DOCUMENT 1136 REV G Instruction Manual Pro APF Series LED ICAO TCL IHP STP 17 12 Tables and Figures Figure 4 Top View of Light Unit...

Страница 24: ...DOCUMENT 1136 REV G Instruction Manual Pro APF Series LED ICAO TCL IHP STP 18 Figure 5 Front View of Light Unit Feed Through fitting Fixture Lead Pressure Port Inner Cover...

Страница 25: ...DOCUMENT 1136 REV G Instruction Manual Pro APF Series LED ICAO TCL IHP STP 19 Figure 6 Sectioned View of Light Unit...

Страница 26: ...OUT HEATERS Figure 9 UNIDIRECTIONAL UNIT P1 CONFIG WITH HEATER FEED THRU ASSEMBLY P1 P100 P101 P103 P102 J203 J300 LED MODULE SIDE A J200 RED BLACK P100 P101 P103 P102 LED MODULE SIDE A LED MODULE SID...

Страница 27: ...IRECTIONAL UNIT P2 CONFIG WITHOUT HEATERS LED MODULE SIDE B P100 P101 P103 P102 LED MODULE SIDE A HEATER SIDE A HEATER SIDE B J203 J300 J200 RED BLACK FEED THRU ASSEMBLY P1 P100 P101 P103 P102 LED MOD...

Страница 28: ...2 BIDIRECTIONAL UNIT P2 CONFIG WITH HEATERS P100 P101 P103 P102 LED MODULE SIDE A HEATER SIDE A FEED THRU ASSEMBLY P1 FEED THRU ASSEMBLY P1 J203 J300 J200 RED BLACK P100 P101 P103 P102 LED MODULE SIDE...

Страница 29: ...ro APF Series LED ICAO TCL IHP STP 23 Figure 13 BIDIRECTIONAL UNIT B1 CONFIG WITHOUT HEATERS P100 P101 P103 P102 LED MODULE SIDE B P100 P101 P103 P102 LED MODULE SIDE A FEED THRU ASSEMBLY P1 J203 J300...

Страница 30: ...LED ICAO TCL IHP STP 24 Figure 14 BIDIRECTIONAL UNIT B1 CONFIG WITH HEATERS P100 P101 P103 P102 LED MODULE SIDE B HEATER SIDE B P100 P101 P103 P102 LED MODULE SIDE A HEATER SIDE A FEED THRU ASSEMBLY...

Страница 31: ...X X Table 1 Light Unit Part Numbers and Jumper Settings 19 17 15 13 11 9 7 5 3 1 20 18 16 14 12 10 8 4 2 19 17 15 13 11 9 7 5 3 1 20 18 16 14 12 10 8 4 2 19 17 15 13 11 9 7 5 3 1 20 18 16 14 12 10 8 4...

Страница 32: ...10 15 8 3 10 15 14 3 10 15 65 IHPI 6 9 10 15 STPI 7 1 10 15 FIG 2 14 TCLI 9 4 10 15 12 8 10 15 18 8 10 15 65 TCLI 8 6 10 15 11 3 10 15 17 3 10 15 65 IHPI 9 4 10 15 STPI 9 8 10 15 FIG 2 15 TCLI 7 9 10...

Страница 33: ...00 TCLI 23 1 20 25 40 3 30 45 46 3 20 25 100 IHPI 22 9 20 25 STPI 23 1 20 25 FIG 2 14 TCLI 25 4 30 45 44 8 30 45 50 8 20 25 100 TCLI 24 6 20 25 43 3 30 45 49 3 20 25 100 IHPI 25 4 20 25 STPI 25 8 30 4...

Отзывы: