background image

EUROPE (EMEA): 

+44 (0)1582 723633 
[email protected]

THE AMERICAS: 

+1 800 835 7075 

 

[email protected]

ASIA-PACIFIC: 

+65 6 645 9888 
[email protected]

The given data is only intended as a product 

description and should not be regarded as a legal 

warranty of properties or guarantee. In the interest 

of further technical developments, we reserve the 

right to make design changes.

Eaton Electric Limited,

 

Great Marlings, Butterfield, Luton
Beds, LU2 8DL, UK.
Tel: + 44 (0)1582 723633 Fax: + 44 (0)1582 422283
E-mail: [email protected]
www.mtl-inst.com

© 2022 Eaton

All Rights Reserved

Publication No. INM F300 Rev 9 070422

April 2022

AUSTRALIA

Eaton Electrical (Australia) Pty Ltd,  

10 Kent Road, Mascot, New South Wales, 2020, Australia
Tel: +61 1300 308 374 Fax: +61 1300 308 463

E-mail: [email protected]

BeNeLux

MTL Instruments BV

Ambacht 6, 5301 KW Zaltbommel

The Netherlands 
Tel: +31 (0) 418 570290 Fax: +31 (0) 418 541044

E-mail: [email protected] 

CHINA

Cooper Electric (Shanghai) Co. Ltd

955 Shengli Road, Heqing Industrial Park

Pudong New Area, Shanghai 201201
Tel: +86 21 2899 3817 Fax: +86 21 2899 3992

E-mail: [email protected]

FRANCE

MTL Instruments sarl,

7 rue des Rosiéristes, 69410 Champagne au Mont d’Or

France
Tel: +33 (0)4 37 46 16 53 Fax: +33 (0)4 37 46 17 20

E-mail: [email protected]

GERMANY

MTL Instruments GmbH, 

Heinrich-Hertz-Str. 12, 50170 Kerpen, Germany
Tel: +49 (0)22 73 98 12 - 0 Fax: +49 (0)22 73 98 12 - 2 00

E-mail: [email protected]

INDIA

MTL India, 

No.36, Nehru Street, Off Old Mahabalipuram Road

Sholinganallur, Chennai - 600 119, India
Tel: +91 (0) 44 24501660 /24501857 Fax: +91 (0) 44 24501463 

 

E-mail: [email protected]

ITALY

MTL Italia srl, 

Via San Bovio, 3, 20090 Segrate, Milano, Italy
Tel: +39 02 959501 Fax: +39 02 95950759

E-mail: [email protected]

JAPAN

Cooper Industries Japan K.K.

MT Building 3F, 2-7-5 Shiba Diamon, Minato-ku

Tokyo, Japan 102-0012
Tel: +81 (0)3 6430 3128 Fax:+81 (0)3 6430 3129

E-mail: [email protected]

NORWAY

Norex AS

Fekjan 7c, Postboks 147,  

N-1378 Nesbru, Norway 
Tel: +47 66 77 43 80 Fax: +47 66 84 55 33

E-mail: [email protected]

RUSSIA

Cooper Industries Russia LLC

Elektrozavodskaya Str 33

Building 4

Moscow 107076, Russia 
Tel: +7 (495) 981 3770 Fax: +7 (495) 981 3771

E-mail: [email protected]

SINGAPORE 

Eaton Electric (Singapore) Pte Ltd

100G Pasir Panjang Road

Interlocal 

Centre 

 

    

#07-08 

Singapore 

118523 

 

    

#02-09 to #02-12 (Warehouse and  Workshop)
Tel: +65 6 645 9888 ext 9864/9865  

 

 

 

Fax: 65 6 645 9811

E-mail: [email protected]

SOUTH KOREA

Cooper Crouse-Hinds Korea

7F. Parkland Building 237-11 Nonhyun-dong Gangnam-gu,

Seoul 135-546, South Korea.
Tel: +82 6380 4805 Fax: +82 6380 4839

E-mail: [email protected] 

UNITED ARAB EMIRATES

Cooper Industries/Eaton Corporation  

Office 205/206, 2nd Floor SJ Towers, off. Old Airport Road,  

Abu Dhabi, United Arab Emirates
Tel: +971 2 44 66 840 Fax: +971 2 44 66 841

E-mail: [email protected]

UNITED KINGDOM

Eaton Electric Limited,  

Great Marlings, Butterfield, Luton

Beds LU2 8DL
Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283

E-mail: [email protected]

AMERICAS

Cooper Crouse-Hinds MTL Inc. 

3413 N. Sam Houston Parkway W.

Suite 200, Houston TX 77086, USA
Tel: +1 800-835-7075 Fax: +1 866-298-2468

E-mail: [email protected]

Содержание Crouse-Hinds Megablock F300 Series

Страница 1: ...F300 megablock range MTL fieldbus device couplers April 2022 INM F300 Rev 9 Instruction manual MTL fieldbus networks...

Страница 2: ...tion of Conformity A printed version of the Declaration of Conformity has been provided separately within the original shipment of goods However you can find a copy of the latest version at http www m...

Страница 3: ...r Requirements 4 5 2 Terminator 4 5 3 Trunk connections 4 5 4 Spur port connections 5 5 5 Surge protection 5 6 TESTING 6 6 1 Power LED 6 6 2 Spur LEDs 6 7 ROUTINE MAINTENANCE 6 8 ATEX UKCA SAFETY INST...

Страница 4: ...this manual and the product datasheet Ensure installation and operating personnel have received adequate training for this task Ensure that any operating instructions are fully understood by the pers...

Страница 5: ...fitted to any of the Megablock fieldbus terminals to provide protection against induced surges and transients that can potentially destroy or degrade certain components inside the F300 Megablocks 2 D...

Страница 6: ...standard connector for the Megablock is a pluggable screw terminal elevator type Pluggable spring clamp connectors rely on constant spring pressure to maintain contact with the wire To order Megablock...

Страница 7: ...then engage the DIN rail clips under the ledge of the DIN rail Push the Megablock against the edge of the rail then rotate the Megablock until it sits flat onto the DIN rail then release the pressure...

Страница 8: ...that the T F97 molded logo is facing inwards towards the body of the Megablock otherwise difficulty will be experienced in accessing the spring clamp buttons to remove it For screw terminals loosen t...

Страница 9: ...tor provides and cable screen S connections See section 5 5 for information on cable screen grounding Cable screen connections The S screen terminals for the trunk and the spurs are interconnected com...

Страница 10: ...d tighten its securing screws 7 Repeat 5 and 6 for all the other FS32 modules A separate grounding bar F300 BAR is used for the trunk connector which must be similarly connected to ground see Figures...

Страница 11: ...tice EN 60079 14 In addition particular industries or end users may have specific requirements relating to the safety of their installations and these requirements should also be met For the majority...

Страница 12: ...ion and maintenance should be carried out in accordance with European national and local regulations which may refer to the standard EN 60079 17 In addition specific industries or end users may have s...

Страница 13: ...9 INM F300 Rev 9 9 FM CONTROL DRAWINGS...

Страница 14: ...10 INM F300 Rev 9...

Страница 15: ...11 INM F300 Rev 9...

Страница 16: ...eded by transient disturbances of more than 140 of the rated voltage 3 The apparatus shall only be installed in an area of at least pollution degree 2 as defined in IEC 60664 1 See footnote Ex ic IIC...

Страница 17: ...13 INM F300 Rev 9 10 2 IECEx Control drawings F97 Megablock Part Numbers Wire Requirements Specific Conditions of Use...

Страница 18: ...14 INM F300 Rev 9 F97 Megablock Part Numbers Wire Requirements Specific Conditions of Use...

Страница 19: ...15 INM F300 Rev 9 F97 FISCO ic FNICO Installation Requirements Wire Requirements Specific Conditions of Safe Use Megablock Part Numbers...

Страница 20: ...n Terminator and Connector Partition Terminator and Connector Installed Repair and Maintenance Certification Markings F3xx Partition Installation Connector Installation Terminator Installation DIN Rai...

Страница 21: ...17 INM F300 Rev 9 11 CCC INSTRUCTIONS...

Страница 22: ...18 INM F300 Rev 9...

Страница 23: ...19 INM F300 Rev 9...

Страница 24: ...20 INM F300 Rev 9...

Страница 25: ...21 INM F300 Rev 9 THIS PAGE IS LEFT INTENTIONALLY BLANK...

Страница 26: ...Old Mahabalipuram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail mtlindiasales eaton com ITALY MTL Italia srl Via San Bovio 3 20090 Segrate Milano...

Отзывы: