5
4000 Series Char-Lynn Motors
Disassembly
9 Remove valve plate.
10 Remove 88,6 mm [3.49 inch] I.D. seal from valve plate (see
Figure 5).
11 Remove valve drive (see Figure 5).
12 Remove Geroler. Retain rollers in outer Geroler ring if they are
loose.
13 Remove 2 seals from Geroler, 1 seal on each side of Geroler.
14 Remove drive.
15 Remove 88,6 mm [3.49 inch] I.D. seal from bearing housing.
17 Remove shaft seal, back-up ring (if used) and dust seal from flange.
Use a small screwdiver to remove dust seal. Do not damage bore of
flange.
16 Use a stud remover or vise grips to remove studs (earlier models
only). Clamp bearing housing in vise as shown in Figure 7. Loosen 8
screws. Remove screws, washers (discard washers, as they are not
required for reassembly), and mounting flange (see Figure 8).
Valve
Plate
Seal
Seal
Valve Drive
Figure 5
Figure 6
Seal
Seal
Geroler
Drive
Figure 7
Figure 8
Shaft
Seal
Back-up
Ring
Mounting
Flange
Dust
Seal
Figure 9