About the Log Book

14

This table should be fi lled in by the Competent Person when 
they visit the site to perform maintenance on the system. 
This should include service visits as well as visits to correct 
faults or false fi res on the system.

MAINTENANCE WORK

Date 

Time 

Zone/Location 

Reason for  

Work Carried  

Additional Work 

Signed

Work

Out

Required

06/09/14 

08:00 

Zone 1 / Reception  Fault shown on 

Faulty detector 

None 

Mr C. Person

Zone 1

replaced

07/09/14 

08:00 

Zone 3 / Kitchen 

Unwanted Fire  

Detector type 

None 

Mr C. Person

on Zone 3 

changed for Smoke

This table should be fi lled in by the Premises Management 
when the event occurs and further detail added by the 
Competent Person at a maintenance visit (if required)

UNWANTED (FALSE) FIRES

Date Time Zone/  Cause 

if Maintenance Maintenance 

Category 

Further Signed

Location 

Known 

Visit 

Needed 

Findings 

Further 

Action

(YES/NO)

Alarm 

Required

07/09/14  07:00 

Zone 3 /  

Unknown 

YES 

Incorrect  

None 

Mr P.

Reception 

detector type  

Manager

fi tted

This table should be fi lled in by the Premises Management 
when a fault occurs; there is a disablement, enablement, a 
genuine fi re condition, and weekly tests.

ALL OTHER EVENTS (EXCLUDING MAINTENANCE AND FALSE FIRES)

Date 

Time 

Zone/Location 

Details of  

Action Required 

Date 

Initials

Event

Out

Completed

05/09/14 

08:00 

Zone 1 /  

Weekly test, 

 None, sounders 

05/09/2014 

PM

Reception 

call point activation  activated.

06/09/14 

07:00 

Zone 1 /  

Zone 1 fault 

Service visit  

06/09/2014 

PM

Reception

indication

required

March

 2016 

  www.eaton.com 

EATON BiWire Flexi User Manual   (

PR215-216-519-03 15-03-16

, PINSTFLEXIUSER)

Содержание BiWire Flexi

Страница 1: ...Conventional Fire System BiWire Flexi Fire Panel EFBW8ZONE FLEXI EFBW4ZONE FLEXI EFBW2ZONEFLEXI User Manual...

Страница 2: ...vel 2 5 4 WHAT TO DO INSTRUCTIONS 6 4 1 What To Do In The Event Of a Fire Alarm Condition 6 4 2 What To Do In The Event Of a Fault Condition 6 4 3 What To Do When Re Enabling Zones With Latching Detec...

Страница 3: ...ine testing and filling in the log book as required by BS5839 part 1 After the system has been installed and commissioned by a Competent Person the Premises Management for the site must ensure that al...

Страница 4: ...e failure of the panel the service company must be contacted immediately Repeater Fault Communication with a repeater panel has been lost 3 Battery Fault Battery voltage missing Mains Fault Mains supp...

Страница 5: ...are available for this level Silence Fire Alarm Devices BiWire Zones and Conventional Sounder Circuits Sound Fire Alarm Devices BiWire Zones and Conventional Sounder Circuits Reset System Mute Buzzer...

Страница 6: ...o silence the fire alarm devices and reset the system Note the time the fire alarm occurred and log the fire event in the log book If the fire alarm was a false activation i e there was no fire then t...

Страница 7: ...details Record the weekly test results in the log book IT IS THE RESPONSIBILITY OF THE PREMISES MANAGEMENT TO DEFINE A FIXED DAY AND TIME OF WEEK THAT THE WEEKLY TEST IS PERFORMED THIS MUST BE COMMUNI...

Страница 8: ...buzzer will continue sounding This function will immediately exit back to Access Level 1 6 3 Sound Fire Alarm Devices This function is only available at access level 2 and when the alarms are silent E...

Страница 9: ...ts will have their associated disabled indicator lit and all enablements will have their associated disabled indicators unlit The function always starts at Zone 1 When an item is selected for disablem...

Страница 10: ...emain lit When a fire detection device or manual call point is activated in the zone under test it will sound all fire alarm devices for 3 seconds and then will automatically silence Any fire conditio...

Страница 11: ...escription of where the zone is on the site and or what rooms are in the zone This defines the mode configuration of the zone which dictates the type of devices that can be fitted Quantities of each d...

Страница 12: ...YES NO Auxiliary Relay 6 YES NO Auxiliary Relay 7 YES NO Auxiliary Relay 8 YES NO Circled if connected to external equipment Explains what happens when these outputs are activated in the event of a fi...

Страница 13: ...work false alarms in accordance with BS5839 part 1 and any other event this includes genuine fires and faults SITE DETAILS Premises Management Names Mr P Manager Company Name of Premises Site Address...

Страница 14: ...maintenance visit if required UNWANTED FALSE FIRES Date Time Zone Cause if Maintenance Maintenance Category Further Signed Location Known Visit Needed Findings Further Action YES NO Alarm Required 07...

Страница 15: ...ders Short or Open circuit condition on the sounder circuit FRE Fault ON ON SLOW SLOW Short or Open circuit condition on the FRE FPE Fault ON ON SLOW SLOW Short or Open circuit condition on the FPE Zo...

Страница 16: ......

Отзывы: