background image

7

614-06819-00

3. UPS connections

• 

 Connect the UPS 

1

 to the AC-power system via a wall outlet with an earth connector, 

using the supplied cord 

4

 for a UPS with FR/DIN sockets or with the supply cord of 

your computer for a UPS with IEC sockets

 

(see figure A).

• 

 Plug critical equipment (computer, monitor, modem, etc.) into the outlets 

19

 providing 

battery backup power and surge protection (see figure B), taking care not to exceed 

the rated current indicated in amperes.

•   Other devices (printer, scanner, fax, etc.) can be connect to the filtered outlets 

18

 

that provide surge protection (see figure B). The filtered outlets are not backed up by 

battery power in the event of a power outage.

Optional Internet modem / Network connection:

A modem or Ethernet data line can be protected against surges by connecting it via 

the UPS. Connect the existing device cable between the wall outlet and the UPS, and 

use a similar cable between the UPS and the device, as indicated in figure C (cable not 

supplied).

Optional USB connection:

The UPS device can be connected to the computer using the USB cable 

5

 supplied.

The software is available on the CD-ROM 

5

 or Eaton UPS Companion software is 

downloadable from powerquality.eaton.com (see figure C). 

Register for the warranty on powerquality.eaton.com.  

4. Master and EcoControl outlets operating procedure

In order to limit energy consumption of peripherals (scanner, printer) in standby mode, 

the Eaton 5S is equipped with EcoControl outlets that are dependent on the Master 

outlet. When the main application supplied by the Master outlet (computer) is shut 

down, the EcoControl outlets are automatically deactivated and the peripherals shut 

down. 

This function (deactivated by default) is validated and configured using the configuration 

tool integrated in the software.

Note: 

when the function is activated, do not connect critical applications to 

EcoControl 

outlets.

Threshold setup

A default setup ensures the correct operation of the EcoControl function. However, 

depending on the consumption of the main load, the trigger threshold of the EcoControl 

function may have to be modified using the configuration software supplied with the 

UPS:

• 

 First, make sure that the function is activated in the "EcoControl Function" tab of the 

configuration tool.

• 

 If the peripherals connected to the EcoControl outlets do not switch off when the main 

load is not in normal operation (ex: when in standby mode), the detection threshold 

value must be set to 

High

.

• 

 If the rated consumption level of the main load is low and the EcoControl outlets shut 

down when the main load is operating normally, the detection threshold value must 

be set to 

Low

.

Содержание 5S 850

Страница 1: ...Installation and user manual EATON 5S 850 1200 1600 ...

Страница 2: ... 614 06819 00 2 3 1 5 EATON 5S Packaging l Before installing the Eaton 5S read the booklet 3 containing the safety instructions to be respected Then follow the instructions given in this manual 2 Caution ...

Страница 3: ...3 614 06819 00 Quick start B C A 1200 1600 850 D ...

Страница 4: ...e life is reduced by 50 for every ten degrees above 25 C The battery elements must be replaced exclusively by qualified personnel risk of electrocution with new elements approved by Eaton to ensure correct operation of the UPS The battery must be disposed of in accordance with applicable regulations To remove the battery elements shut down the UPS button 6 OFF remove the power cord and proceed as ...

Страница 5: ...max 7 3 A max Leakage current 0 4 mA Input protection 10 A resettable circuit breaker Transfer time 5 ms typical Telephone surge protection Tel ISDN ADSL Ethernet Sealed lead acid battery 12 V 9 Ah 2 x 12 V 7 Ah 2 x 12 V 9 Ah Automatic battery test Once a week Average battery life 4 years typical depending on temperature and amount of discharge cycles Operating temperature 0 to 35 C Storage temper...

Страница 6: ...UPS can be installed in horizontal vertical position or placed in Rack 2U optional kit 2 Description AVR Min Hz kVA kW 6 7 8 6 ON OFF button for the battery backup outlets 7 Scroll down 8 Mute alarm LCD 16 15 14 17 11 10 9 12 13 9 UPS ON 10 AVR mode 11 Battery mode 12 Internal fault 13 Output load level 14 Battery level 15 Input measurements 16 Output measurements 17 Measuring unit Outlets 20 19 1...

Страница 7: ...Register for the warranty on powerquality eaton com 4 Master and EcoControl outlets operating procedure In order to limit energy consumption of peripherals scanner printer in standby mode the Eaton 5S is equipped with EcoControl outlets that are dependent on the Master outlet When the main application supplied by the Master outlet computer is shut down the EcoControl outlets are automatically deac...

Страница 8: ...Filtered outlets 18 without battery backup Equipment connected to these outlets is supplied as soon as the AC cord 4 is plugged in They are not affected by button 6 Battery backup outlets 19 Equipment connected to these outlets is supplied as soon as button 6 turns green see figure D These outlets can be turned on even if the UPS is not connected to AC power button 6 flashes 6 UPS setting through ...

Страница 9: ...er supplied Call after sales support 6 EcoControl outlets keep powered when main application Master outlet is stopped EcoControl function is not activated or not properly set Activate or set properly EcoControl function using the software provided with the product 8 Troubleshooting AC power disturbance If AC power is disturbed or fails the UPS continues to operate on battery power Button 6 flashes...

Страница 10: ......

Отзывы: