5. Maintenance
5.2 Battery-module replacement
Safety recommendations
The battery can cause electrocution and high short-circuit currents. The following safety precautions
are required before servicing the battery components:
•
remove watches, rings, bracelets and all other metal objects from the hands and arms,
•
use tools with an insulated handle.
Battery tray removal on tower models
A
A
- Remove the front panel.
B
B
- Disconnect the battery block by
separating the two connectors
(never pull on the wires).
C
C
- Remove the plastic protection cover
in front of the battery (one screw).
D
D
- Pull the plastic tab to remove
the battery block and replace it.
Mounting the new battery module
Carry out the above instructions in reverse order.
•
To ensure safety and high performance, use only batteries supplied by EATON.
•
Take care to firmly press together the two parts of the connector during remounting.