background image

Содержание 5E

Страница 1: ...DSD 5E2206 English Eaton 5E Advanced User Guide 5E700UI EA 5E900UI EA 5E1200UI EA 5E1600UI EA 5E2200UI EA Copyright 2023 EATON All rights reserved...

Страница 2: ......

Страница 3: ...ort 9 5 Operation 10 5 1 Start up and normal operation 10 5 2 Starting the UPS on battery 11 5 3 UPS shutdown 11 5 4 Operating modes 12 5 5 Return of AC input power 12 6 UPS maintenance 13 6 1 Equipme...

Страница 4: ......

Страница 5: ...k of energy or electrical shock or burn from high short circuit current Observe proper precaution Batteries may contain HIGH VOLTAGE and CORROSIVE TOXIC and EXPLOSIVE substances Information advice hel...

Страница 6: ...protection Eaton has implemented an environmental protection policy Products are devel oped according to an eco design approach 2 1 1 Substances This product does not contain CFC and HCFC This produc...

Страница 7: ...ons concerning batteries The battery may be removed to comply with regulations and in view of correct disposal 2 2 Benefits The Eaton 5E uninterruptible power system UPS protects your sensitive electr...

Страница 8: ...ts kg lbs Dimentions mm inch D x W x H 5E700UI EA 4 2 9 3 288 x 100 x 148 11 5 x 3 9 x 5 8 5E900UI EA 5 2 11 4 288 x 100 x 148 11 5 x 3 9 x 5 8 5E1200UI EA 8 2 18 2 330 x 133 x 180 13 0 x 5 2 x 7 1 5E...

Страница 9: ...ront panel 1 2 3 3 3 Rear panel 5E700UI EA 5E900UI EA 1 3 1 3 1 3 2 2 2 4 5E1200UI EA 5E1600UI EA 5E2200UI EA 1 AC Input 3 Breaker 2 AC Output 4 Fan 1 USB communication port 2 ON OFF Button 3 UPS stat...

Страница 10: ...le with the carrier within 15 days of receipt of the equipment 2 Send a copy of the damage claim within 15 days to your service representative Check the battery recharge date on the shipping carton la...

Страница 11: ...located on the back of the UPS correspond to the AC power source and the true electrical consumption of the total load Connect the UPS to the AC power source with cable through a wall outlet equipped...

Страница 12: ...ent computer monitor modem etc to the backup pro tected outlets providing battery backup power taking care not to exceed the rated current indicated in amperes Equipment connected to these outlets is...

Страница 13: ...9 4 4 USB COM port Connect the UPS to the computer using the USB cable Enhance your purchase by downloading the monitoring software Eaton UPS Com panion using URL eaton com downloads...

Страница 14: ...zer temporarily when there is a fault occur or battery test fail 2 UPS on off Push the button for 2s then to power on off the UPS 3 Silence mode Let UPS working in the standby mode then to push the bu...

Страница 15: ...om Standby mode to Battery mode The indicator blinking and the buzzer snooze The UPS supplies power to your equipment 2 Check the UPS front panel display for active alarms or notices besides the Bat t...

Страница 16: ...low while in Battery mode the audible alarm beeps faster This warning is approximate and the actual time to shutdown may vary signifi cantly gracefully shutdown all applications on connected equipmen...

Страница 17: ...temperature below 10 C 6 2 Storing the equipment If you store the equipment for a long period recharge the battery every 6 months by connecting the UPS to utility power The internal batteries charge...

Страница 18: ...eries and must be disposed of properly For more information con tact your local recycling reuse or hazardous waste center Do not discard waste electrical or electronic equipment WEEE in the trash For...

Страница 19: ...tlets are not supplied with power or the UPS cannot be turn on after pressing the button The ON OFF Button is not pressed or the ON OFF but ton is pressed too briefly Press the button continuously for...

Страница 20: ...service representative 7 1 Service and support If you have any question or problem with the UPS call Eaton or your local ser vice representative in your country region Please have the following infor...

Страница 21: ...E900UI EA 4 8A 5E1200UI EA 6 0A 5E1600UI EA 8 6A 5E2200UI EA 10A 8 2 Electrical output All models Normal mode Battery mode Voltage regulation Boost1 Vin 1 2 Boost2 Vin 1 4 Buck Vin 0 857 10 15 Efficie...

Страница 22: ...nced monitoring for earlier failure detection by indicators 8 4 Environmental and safety Standards IEC EN 62040 1 Safety IEC EN 62040 2 Electromagnetic Compatibility EMC IEC EN 62040 3 Performance EMC...

Страница 23: ...40 C 32 to 104 F Storage temperature 0 to 40 C 32 to 104 F with battery 25 to 55 C 13 to 131 F without battery Relative humidity Storage 0 93 non condensing Operation 0 85 non condensing Operating alt...

Страница 24: ...connected to the UPS output Normal mode The normal UPS operating mode in which the AC source supplies the UPS which in turn provides AC power to the connected loads Normal AC source Normal source of...

Страница 25: ......

Отзывы: