ICU CONDENSING UNIT INSTALLATION MANUAL 

 

 

September2003:E\Manuals\Others\Qualitair\ICC\0412118  

 

 

 

 

 

19

 

 

C

C

 

 

E

E

 

 

 

 

 

 

C

C

 

 

E

E

 

 

R

R

 

 

T

T

 

 

I

I

 

 

F

F

 

 

I

I

 

 

C

C

 

 

A

A

 

 

T

T

 

 

E

E

 

 

 

Eaton-Williams Air Conditioning 

(Eaton-Williams Ltd) 

Station Road – Edenbridge - Kent - TN8 6EG - England 

Telephone ... 44 (0)1732 866055 

Telefax ... (0)1732 863461 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   Qualitair  Edenaire  Moducel

 

 

We declare that the equipment designated below, 

on the basis of design and construction in the form marketed by us and 

when installed and operated in accordance with our information and instructions, 

conforms to the EMC Directive, the PED and the essential Health and Safety requirements of the Machinery 

Directive. 

 

If alterations are made to this equipment without our approval, 

this declaration becomes invalid.  Furthermore, this equipment may be 

assembled into other systems which may also constitute machinery and shall 

not be put into service until the assembled system has been declared in conformity 

with the Machinery Directive. 

 
 

 

Model    

 

 

 

 

Serial N° 

 

 

  Standards 

Applied  

 

 

 

 

 

BS EN 292-Pt2 

  EMC 

  BS 

EN50081-1 

 

 

  EMC 

  BS 

EN50082-1 

 

 

  Low 

Voltage 

 

 EN60204 

pt1 

  Pressure 

Equipment 

prEN14276-2 

 
  Controls 

Applied 

 BS 

EN 

ISO 

9001: 

1994 

     BSI 

Registered 

Company 

Q5026 

 

 

 
 

 

 

Gerry Stapley 

 

 

Gary Martin

 

 

 

 

  

Managing Directors 

 

ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 

89/336/EEC 

 

MACHINERY DIRECTIVE 

EC Declaration of Conformity 

As Defined by the EC Council Directive on Machinery 

 

89/392/EEC Annex IIA and amended by 

91/368/EEC - 93/44/EEC & 93/68/EEC 

Содержание ICU30

Страница 1: ...Lt td d INSTALLATION MANUAL ICU CONDENSING UNIT IF SUPPLIED AS A SYSTEM ICC QKK QLC PLEASE REFER TO INDOOR UNIT INSTALLATION MANUAL Eaton Williams Ltd Station Road Edenbridge Kent TN8 6EG Tel 44 0 173...

Страница 2: ...ixings 6 5 General Service Connection 7 6 Power Control Connections 8 6 1 Wiring up the unit 9 6 2 Wiring Requirements 9 6 3 Terminations 9 6 4 Wiring Diagrams 9 7 Refrigerant Pipe Connections 10 7 1...

Страница 3: ...ical hazards are kept to a minimum 3 The equipment has been fitted with doors and covers to prevent access during operation These must be kept in place and additional guards fitted if necessary 4 The...

Страница 4: ...is supplied complete with axial fan and guard hermetic compressor shut off service valves fan speed controller low pressure switch high pressure switch start delay timer winter start and an electrica...

Страница 5: ...secure the unit to a suitable plinth or to the wall mount bracket kit If required the contractor should install the unit on anti vibration pads 3 3 Service Connections The refrigerant pipe 4 and elec...

Страница 6: ...ess panel 5 Removable top panel Front and side access screw fixings 6 Service access panel Front access screw fixings 7 Reversing valve Heat pump unit only HP LP cut outs Remove service access panel 8...

Страница 7: ...3 8 1 2 Suction 7 2 5 8 5 8 5 8 3 4 3 4 7 8 7 8 Mains Power Cable No of Cores ICU30 ICU40 ICU55 ICU80 ICU100 ICU135 ICU170 Single Phase System 3 3 3 3 3 N A N A Three Phase System N A N A N A 5 5 5 5...

Страница 8: ...RV Heating signal from Indoor unit H Heating Signal From Indoor Unit defrost heating ICU THREE PHASE COOLING ONLY ICU Terminal Customer Connections PE Customer Earth Connection E N Customer Neutral C...

Страница 9: ...les in Section 5 Page 7 of this manual Note On units with 3 phase power supplies ensure the 3 phases are connected in the correct rotation ie L1 L2 L3 If the phase rotation is incorrect the compressor...

Страница 10: ...e Ensure the refrigerant lines are adequately supported using refrigerant pipe clips ICU170 units are supplied with a length of 7 8 od flared pipe to assist connection to shut off valve 7 3 Unit Conne...

Страница 11: ...3 8 3 8 3 8 30m 105g m 1 2 liquid ICU80 Suction 5 8 5 8 7 8 7 8 7 8 7 8 7 8 7 8 7 8 7 8 11 8 Suction 30 None 5m 40g m 3 8 Liquid Liquid 3 8 3 8 3 8 3 8 30m 105g m 1 2 liquid ICU100 Suction 5 8 7 8 7...

Страница 12: ...3 4 ICU100 Vertical Liquid 5 8 25m Added Oil None required 10m EVAP 10m FROM TABLE A Horizontal Suction to be 11 8 EVAP Horizontal Liquid to be 5 8 25m TABLE B Not applicable Added Oil None required 1...

Страница 13: ...losed 3 System Isolation After achieving the specified system vacuum close the gauge low pressure port 5 and switch off the vacuum pump Leave the system for 1 hour and check that the vacuum is maintai...

Страница 14: ...the unit by phase control and keeps a definite condensing pressure to ensure stability WARNING Before adjusting be sure to TURN OFF THE POWER SUPPLY Adjustment Method 1 Range adjustment The set value...

Страница 15: ...ost water from Heat Pump Outdoor units and the potential danger from freezing if allowed to run onto a roof or similar area A separate drain tube plate is provided with the unit which fits over a 15mm...

Страница 16: ...particular protection of lungs eyes and skin from refrigerants dust etc Only approved lifting gear and power tools should be used and access to the work area be restricted to authorised personnel Dis...

Страница 17: ...ed 4 Has correct HRC external fusing isolating been installed 5 Has additional extended pipe run refrigerant charge been measured into the system where necessary or heat pumps been charged correctly 6...

Страница 18: ...55 80 Cooling Only Condensing Unit 1 ph TS FSC A3LBD138 J90763 J90783 ICU80 Cooling Only Condensing Unit 3 ph TS FSC A3LBD139 J90784 ICU100 Cooling Only Condensing Unit 1 ph PS FSC A3LBD140 J90723 ICU...

Страница 19: ...the Machinery Directive If alterations are made to this equipment without our approval this declaration becomes invalid Furthermore this equipment may be assembled into other systems which may also c...

Страница 20: ...E Manuals Others Qualitair ICC 0412118 20 STATION ROAD EDENBRIDGE KENT TN8 6EG TEL 01732 866066 FAX 01732 867937 AN EATON WILLIAMS COMPANY As part of the policy of continuous product improvement we re...

Отзывы: