board, and tighten it in clockwise direction. 

7.  Connect the two-cored air plug of the foot switch respectively to the 

two-cored and three-cored sockets on the panel board. 

 
After finishing all the work above, you can start welding. 

 

OPERATION 

 
1. Turn on the power switch, the fan begins to work. 

 
2. Turn on the gas switch; adjust the gas to rated standard. (See parameter) 
 

3. According to the oxidization degree of the work piece, adjust the switch for 

clean width to change the positive and negative current rate. 

 

4. Turn on the switch on the welding torch, and the electromagnetic valve works; 

you will hear the sound of HF electricity-releasing. Meanwhile, there is gas 

coming out of the torch mouth. Attention: If it’s the first time to weld, please 

hold the switch for seconds before welding; don’t begin welding until all the 

air in the gas road is made out. After you finish welding, there will be still 

being gas out for seconds. This is designed for protecting the welding point, 

so please stay in the welding place for seconds before removing the torch. 

 

5. According to practical use, choose the foot switch. If the foot switch is in use, 

please turn the current to the minimum, and the current volume is under the 

control of the foot switch. 

 
6. According to practical use, adjust the time of “pre-flow”, “post-flow” and 

“slope-down”. 

 
7. Keep the distance between the tungsten and work piece between 2mm to 

4mm, push the torch switch, then HF electricity-releasing will come out 

between the welding tungsten and work piece; after the arc-leading, the 

splash may disappear at once, then you can start work. 

 

 

 

 

 

 

 

 

 

Содержание Easytig 200AC/DC

Страница 1: ...1 EasyTig Operation Manual TIG AC DC Series Inverter Welding Machine Model Easytig 200AC DC Easytig 300AC DC Easytig 315AC DC Hong Kong EasyWeld Limited ...

Страница 2: ...2 CONTENTS Introduction 3 Warning 4 Main Parameter 6 Installation and Operation 7 Caution Pre cautions 10 Maintenance 12 Troubleshooting 13 ...

Страница 3: ...all our customer service department and report the damage immediately There is a 1 year warranty on all internal electronic parts The torch power cord clamps air regulator hoses case paint and consumables and cables are not covered under warranty You must use dry gas in your machine and keep it indoors away from rain and moisture This machine is designed to operate from 200 240VAC 380VAC at 50 60H...

Страница 4: ...ire so make sure that there are no flammable things nearby the working place Noises too much noise may be harmful to your hearing Please wear something to protect your ears from the noises Warn the look ups of the hidden harm the noise may cause Break down ask the professional for help If you have any problems in setting up or operating please first consult this manual If you still can not underst...

Страница 5: ... clearance etc to make sure the high quality of the machines AC DC series are equipped with foot switch thus liberating the workers hands and they can adjust the current with their foot freely As a result at the very beginning or wire adding we can speed up the current while at the end slow down the current in order to form a good welding line In a word the use of foot switch helps raise the weldi...

Страница 6: ...owntime 5 0 5 0 5 0 5 Tail gas time 5 2 10 2 10 2 10 Air occupy proportion 10 90 10 90 10 90 Remote control Yes Yes yes Arc leading HF vibration HF vibration HF vibration Efficiency 85 85 85 Rated duty cycle 60 60 60 Power factor 0 93 0 93 0 93 Insulation class B B B Protection class IP21 IP21 IP21 Weight kg 32 38 38 Size mm 562X465X467 562X465X467 562X465X467 Max welding thickness mm 10 14 15 Pan...

Страница 7: ...ng the current exchanges between positive and negative directions when Current is from tungsten to work piece its positive direction and tungsten heats little convenient for welding while if current is from work piece to tungsten it s negative and good for removing the oxidization coating on the surface of the work piece but the tungsten may be easily damaged because of overheat This switch is for...

Страница 8: ...e to reduce voltage decreasing we suggest you choose cables with wider section but if the cable is too long it may cause abnormal in the working system so we recommend you use the given length 1 Make sure the ventilating mouth is not blocked or covered lest the cooling system invalid 2 Connect well the C02 source The gas supply includes gas bottle gas hose and gas regulator the connection of the h...

Страница 9: ...h Attention If it s the first time to weld please hold the switch for seconds before welding don t begin welding until all the air in the gas road is made out After you finish welding there will be still being gas out for seconds This is designed for protecting the welding point so please stay in the welding place for seconds before removing the torch 5 According to practical use choose the foot s...

Страница 10: ...ACTIG welding instructions 5 6 7 8 CAUTIONS Any plug in or plug out of cable or connection during the welding is forbidden because such operation may cause harm to either body safety or the equipment Cautions Pre cautions Environment 1 The operation should be in a comparative dry environment the air humidity no more than 90 2 The around temperature should be between 10 C and 40 C 3 Avoid working u...

Страница 11: ...urpass the allowed max Over current may obviously shorten the working year of the machine and even may fire the machine to pieces 3 No over voltage The power voltage is listed in the Main Parameter table generally the automatic compensating circuit may make sure the current is in rated range If the voltage surpasses the allowed value the machine may be damaged The operator should be familiar with ...

Страница 12: ...nd re connect it firmly 4 Avoid water or water gas into the inner of the machine if happens please first dry it and then measure the insulation situation with Omen meter Including the joints and joint vs case Do not continues until you make sure there is no abnormal phenomenon 5 If the machine is not used for long time please put it into the original box and keep it in dry condition PRE CHECKING W...

Страница 13: ...ch should be in on place 2 Renew the potentiometer 5 Hand control normal while foot switch abnormal 1 Slight switch in foot switch broken 2 Sliding potentiometer in the foot switch broken 1 Renew the slight switch 2 Renew 1K sliding potentiometer 6 Abnormal pilot light on 1 Spontaneous over current protection 2 Too much dust causes short circuit 3 Some parts in the machine broken 1 Turn off the ma...

Отзывы: