Programmable Timer Features
• Digital electronic time switch with daily programs
• Repeat programs with 16 on/off settings and manual override
• Lithium battery power reserve to keep time and programs even in power outage.
• Auto time error corr/- 60 sec. weekly
Operation Instructions for Automatic Program Function
1. Plug controller into 110 volt GFCI protected outlet. Red light on timer will come on to indicate
power is being supplied to lights. After timer settings are made, the red light only comes on
during operation of programmed Auto “On” setting or when ON in Manual mode (see Manual
Mode section).
2. Remove clear plastic cover from timer. Be sure not to lose this cover.
3. Unlock the timer by pressing the “C/R” button four times. This removes the “a” character in
lower left corner of the display screen. If no keys are selected in 15 seconds, the time will
automatically lock. Or once programming is finished press “C/R” button to lock.
4. To clear all programs, press the Reset button (labeled as 'c'). It is inset and will require a pen
or small object to depress.
5. Once unlocked, set the time by pressing the button with the clock icon, then use D+ to set
the day of the week, H+ to set the hour (uses military time only) and M+ to set the minute.
6. Up to 16 on/off settings can be programmed using the chart below.
Note: Set times in sequence as you may not cross set. System will auto lock
with no activity or data saved within 15 seconds.
Setting the Timer
Mount the weatherproof controller box in a secure location near a power supply
and plug into 110 volt outlet. The controller is weatherproof and does not need
to be protected from the weather.
PROGRAM
Step
Key
Programming
1
P
Setting 1 ON time (display 1 on)
2
H+/M+
Setting hours and minutes to turn on
3
D+
Daily selects same time or separate times
4
P
Setting 1 OFF time (display 1 off)
5
H+/M+
Setting hours and minutes to turn off
6
D+
If using the same time everyday, do not press
7
Repeat 2-6 Set 2-16 ON/OFF time
8
End
If you do not require 16 settings, press clock icon to the end
ON
OFF
AUTO
Example
Program Functions
Example
Manual Functions