Electrical Specifications
Model 

HP 

Watts* 

Volts 

Amps 

Cable Length

TH150 

1/4 

270-350 

115 

2.6-3.1 

6m/20'

TH1502 

1/4 

270-350 

230 

1.3-1.5 

6m/20'

TH250 

1/3 

345-500 

115 

3.0-4.2 

6m/20'

TH2502 

1/3 

345-500 

230 

1.5-2.1 

6m/20'

TH400 

1/2 

440-670 

115 

3.7-6.0 

6m/20'

TH4002 

1/2 

440-670 

230 

1.8-3.0 

6m/20'

TH750 

600-910 

115 

6.0-9.9 

6m/20'

TH7502 

600-910 

230 

3.0-4.9 

6m/20'

* Actual running conditions affect watts

Pump Specifications
Model 

Max. Flow 

Max. Head 

Outlet 

Weight

TH150 

3100 GPH 

7m/23' 

2" 

6.75kgs/15 lbs.

TH1502 

3100 GPH 

7m/23' 

2" 

6.75kgs/15 lbs.

TH250 

4100 GPH 

9m/30' 

2" 

7.85kgs/18 lbs.

TH2502 

4100 GPH 

9m/30' 

2" 

7.85kgs/18 lbs.

TH400 

5100 GPH 

11m/36' 

2" 

9.07kgs/20 lbs.

TH4002 

5100 GPH 

11m/36' 

2" 

9.07kgs/20 lbs.

TH750 

6000 GPH 

14m/46' 

2" 

10.88kgs/24 lbs.

TH7502 

6000 GPH 

14m/46' 

2" 

10.88kgs/24 lbs.

Safety & Electrical Connections 

1.  

Always disconnect the electricity supply before handling, 

maintaining, repairing or installing any pond equipment.

2.   Always make sure you know the correct amps and voltage required 

before installing.

3.  Use dedicated power outlet only. Sharing the outlet with other equip-

ment may cause overheating and fire.

4.  Always connect to a Ground Fault Circuit (GFCI) to prevent electrical 

shock. Never submerge connecting power cable plug in water.

5.  

Never let the pump run without water as this will damage the 

impeller, over heat and possibly burn out the pump. This pump 

must stay submerged entirely when opeating. If used in a skimmer, 

the debris net must be kept clean to ensure adequate water flow to 

pump. Running pump low on water will cause overheating, premature 

failure and will void warranty.

6.   Do not use this product in bathrooms or swimming pools.
7.   Do not let the water level in your water feature fall below the top of the 

pump body.

8.   All electrical work must be performed by a qualified technician. 

Always follow the National Electrical Code (NEC) or the Canadian 

Electrical Code as well as all local, state and provincial codes. Code 

questions should be directed to your local electrical inspector. Failure 

to follow electrical codes and OSHA safety standards may result in 

personal injury or equipment damage. Failure to follow manufactur-

er’s installation instructions may result in electrical shock, fire hazard, 

personal injury or death, damaged equipment, provide unsatisfactory 

performance and may void manufacturer’s warranty.

9.   Do not attempt to disassemble pump during the warranty period. If 

there are any questions please contact you local dealer.

10.  Never use an extension cord or tamper with power cord. Power cord 

cannot become bent, twisted, abraded or cut. A damged cable may 

cause electric leakage, shock or fire.

11.  The motor has a built-in protection system which stops the pump 

when overheating occurs due to excessive load or low water, this can 

be caused by clogging at inlet/outlet or when flucuations occur in 

power supply.

Installation

•   Do not paint casing, over heating may occur
•  Lift only by handle, not by power cable
•  Do not hang pump in water, install on solid flat base in upright 

position

•  Install proper outlet adapter for pipe or hose
•  Make sure that power cable plug and power outlet are away from 

water and water discharge pipe/hose.

Operation

1.  Do not start operation with people standing near intake or outlet.
2.  Do not operate out of water.
3. 

Never operate below minimum water level, which is 6" above 

base level. For continuous operation pump must be fully 

submersed. Operate for a maximum of 30 minutes if water level is 

between these two levels.

4.  Only use pump for circulation, transfer or removal of water or waste 

water.

5.  Do not pump oil, salt water, chlorinated water or chemical liquids.
6.  Do not allow dry operation
7.  Do not allow foreign objects to enter intake
8.  In case of power outage, turn off power switch to avoid damage when 

power is restarted.

9.  If excessive vibration occurs turn off power immediately.

Service & Maintenance

1.  

Disconnect all power supplies before inspection or service to 

avoid possible electrical shock.

2.   The pump should be removed from the pond on a regular basis, 

cleaned and checked over for damage to prolong the life of the pump.

3.   Clean the impeller and intake screen when the flow is visibly reduced.

4.   Clean the pump and impeller with clean fresh water.
5.   Check inside the impeller housing for large debris or algae, which 

could reduce the flow.

6.   Check and tighten nuts and bolts if required, refer to dealer for advice 

on other repairs.

7.  Winterization/Storage: When the pump is out of use for extended time 

- wash and dry it then store indoors in a non-freezing location. It is 

best to store in a bucket with about an 8" water depth.

8.  If the pump is left in water but not operating regularly, test run it at 

least once a week.

TH Series Pump Trouble Shooting

Humming 

•  Line circuit breaker is off, fuse is burned or loose

 

•  Pump cord is not making contact in receptacle

 

•  May have air lock

Running, no water •  Check valve (optional) is installed backwards

 

•  Discharge shut-off valve closed

 

•  Inlet or impeller clogged

 

•  Pump is air-locked, start and stop several times by

 

  plugging and unplugging cord, may need to 

 

  disconnect and reinstall pump.

 

•  Impeller not turning after extended time out of 

 

  service. Unplug and disconnect pump. Manually turn

 

  the impeller by spinning until free. Reconnect pump

 

  and plug back in.

 

•  Vertical pumping distance is too high or the pipe

 

  size is too small

Running, very  

•  Pump is air-locked, start and stop several times by

little water 

  plugging and unplugging cord

 

•  Vertical pumping distance is too high or the pipe

 

  size is too small

 

•  Inlet or impeller clogged/damaged

 

•  Low water conditions with pump sucking air   

GFCI breaker 

•  Mechanical seals may need to be replaced

tripping 

•  Power cord may be damaged or cut

 

•  Nuisance trip due to improper grounding

 

•  Motor stator may be defective

 

•  Overloaded circuit

Motor briefly 

•  Low water conditions, pump overheating

starts and stops  •  Inlet or impeller clogged

 

•  Improper power supply     

 

•  Motor stator may be defective

Отзывы: