EasyPro TB Series Скачать руководство пользователя страница 2

 

 Volts/    Max  Max

Model 

HP 

Max Amps 

Weight 

Head 

Flow

TB8000 

115/10.9 

43 lbs. 

40' 

8000 GPH

TB8002 

230/5.5 

43 lbs. 

40' 

8000 GPH

TB12000 

230/9.7 

64 lbs. 

60' 

12000 GPH

TB14500 

230/14.5 

72 lbs. 

72' 

14500 GPH

Units have 20' power cords

Safety & Electrical Connections 

WARNING: Verify that the voltage and frequency of the electric 

pump shown on nameplate correspond to those available on mains.

•  The installer must make sure that the electric system is grounded in 

accordance with local ordinances.

•  The plug and connections should be protected from water/rain. 

Before using the pump, always inspect it visually (especially power 

cable and plug).

•  Do not use the pump if it is damaged. If the pump is damaged, have it 

inspected by a qualified service center only.

•  Make sure electric connections are protected from all water and 

moisture. Protect plug and the power cable from heat, oil or sharp 

edges.

WARNING: The power cable must be replaced by qualified 

personnel only.

Grounding: The plug of the power cable has a double grounding contact, 

so that grounding can be performed by simply inserting the plug.

Overload Protection: EasyPro pumps have a built in thermal protection 

switch. The pump stops if an overload condition occurs. The motor 

restarts automatically after it has cooled down.

Prior to Operation

Check the following points upon receipt of your pump:

•  Is the pump exactly what you ordered? Check nameplate. 

•  Has any damage occurred during shipment? 

•  Are any bolts or nuts loose? 

•  Have all necessary accessories been supplied? 

•  We recommend that you keep a spare pump on hand in case of 

emergencies. Keep this instruction manual in a place for future 

reference.

Installation

Limitations:
This pump must stay submerged entirely when operating. If used in 

skimmer, the debris net must be kept clean to ensure adequate water 

flow to the pump. Running pump low on water will cause overheating and 

premature failure which is not covered under warranty.
This series of pumps are suitable to pump water and also can be used 

both for permanent and temporary installation. The pump can be placed 

in a sump pit, then can pump dirty water containing suspended solid 

particles up to 

1

/

2

" diameter.

WARNING: The pump cannot be used for sea water, chlorinated 

water and flammable, corrosive, explosive or dangerous liquids.

Installation:
WARNING: Do not work on pump until power is unplugged.

 

Do not cut off ground pin or use an adapter fitting.

 

Do not use an extension cord

 

Must be used on a GFCI protected outlet

Do install the strainer prior to using if you want to let the pump run as a 

sump pump.
The pump power cord should be connected to a separately fused, 

grounded line with a minimum capacity of 15 amps. It can be connected 

to non- fuse breaker at the recommended amps. Never touch the pump 

when it is plugged in.
1.  Before installing or servicing this pump, be certain pump power 

source is disconnected. Contact a qualified licensed electrician for 

disconnecting electrical service prior to pump removal.

2.  Installation and electrical wiring must adhere to state/local codes 

and must be completed before priming pump. Check appropriate 

community agencies, or contact local electrical and pump 

professionals.

3.  Call an electrician when in doubt. Pump should be connected to 

a separate 15 amp circuit breaker or 15 amp fuse block. Note that, 

plugging into existing outlets may cause low voltage at motor, causing 

blown fuses, tripping of motor overload or burned out motor.

4.  A permanent ground connection from pump to the grounding bar at 

the service panel is mandatory. For maximum safety, connect pump 

to a circuit equipped with a Ground Fault Circuit Interrupter device 

when you position the pump’s grounding wire.

5.  Voltage of power supply must match the voltage of the pump.
WARNING: Must be vented in accordance with local plumbing codes. 

EasyPro pumps are not designed for and CANNOT be installed in 

locations classified as hazardous.
WARNING: The following may cause severe damage to pump and 

will void warranty:
• Using an extension cord

•  Cutting off the ground pin or using an adapter fitting
•  Working on pump or switch while plugged in
•  Removing motor housing, unscrewing impeller or otherwise removing 

impeller seal

•  Pumping chemicals or corrosive liquids including chlorinated or salt water
•  Pumping gasoline or other flammable liquids
•  Piping: Plastic PVC pipe, drain hose, galvanized steel or copper pipe 

may all be used. All piping must be clean and free of all foreign matter 

to prevent clogging. Be sure to seal the thread connection with tape 

seal when you are using the pipe fitting to connect the flange. 

TB High Head Pump Trouble Shooting

Humming 

•  Line circuit breaker is off, fuse is burned or loose
•  Pump cord is not making contact in receptacle
•  Float (optional) is stuck, it should operate freely
•  May have air lock

Running, no water  •  Check valve (optional) is installed backwards

•  Discharge shut-off valve closed
•  Inlet or impeller clogged
•  Pump is air-locked, start and stop several times  

by plugging and unplugging cord, check for 

clogged vent hole, may need to disconnect and 

reinstall pump.

•  Inlet holes in pump base are clogged, remove pump 

and clean the openings. 

•  Vertical pumping distance is too high or the pipe 

size is too small, reduce vertical distance or 

increase the pipe size fittings.

Running, very  

•  Pump is air-locked, start and stop several times by

little water 

  plugging and unplugging cord, check for clogged 

vent hole

•  Vertical pumping distance is too high or the pipe 

size is too small

•  Inlet or impeller clogged/damged
•  Low water conditions with pump sucking air   

GFCI breaker 

•  Fuse size or circuit breaker may be too small.

tripping 

•  Motor stator may be defective
•  Pump impeller or inlet is partially clogged with 

debris

Motor briefly 

•  Low water conditions, pump overheating

starts and stops 

•  Inlet or impeller clogged
•  Improper power supply     
•  Motor stator may be defective

Each year we receive numerous pumps back that simply have a small 

stone lodged in the impellar, are plugged from lack of cleaning or do not 

work due to low voltage caused by an overloaded circuit. These are not 

warranty items. Please take the time to verify your problem is actually 

a defective pump before returning. EasyPro will pay postage to return 

pump to you provided it is a warranty issue. If you send a pump in for 

warranty and it checks out fine — you will also be responsible for the 

cost of return postage.

Отзывы: