6
Maintenance Guidelines
• Keep your compressor and intake filter clean. Any excess dust and debris
on motor or air intake may significantly shorten the life of the compressor.
• Diffusers may need regular cleaning in certain water conditions. This may be
every two to five years.
• Compressors may need to be rebuilt if running but no longer “pumping air.”
Contact your EasyPro dealer for compressor rebuild kits.
• If lines become frozen, a small amount of denatured alcohol can be run
down the frozen line to thaw it out. The small amount of alcohol will not
harm fish or biological processes in your pond.
After one or two years of operation, you will possibly notice a sudden drop in air
bubbles. This is a sign the compressor needs new piston cup or vanes. Rebuild
kits are available to restore like-new performance. Be sure to keep the air filter
clean. Replacement filters are available.
Kit
Replacement
Compressor
Part #
Compressor
Filter/Element
Repair Kits
PA34
SRC25
GAF2/GAFE
SRC25K
PA65
SCR50
GAF2/GAFE
SRC50K
PA66
SRC50
GAF2/GAFE
SRC50K
PA86
SRC75
GAF2/GAFE
SRC75K
PA90
SRC75
GAF2/GAFE
SRC75K
Prior to 2016:
PA34
ERP25
ERPF1/ERPF12E
ERP25K
PA66
ERP50
ERPF1/ERPF12E
ERP50K
PA86 (pre-2017)
ERP75
ERPF2/ERPF12E
ERP75K
Troubleshooting
Compressor Troubleshooting
Low
High
Compressor Excess
Pressure Pressure
Overheating
Noise Cause and Solution
•
•
Dirty air filter, clean or replace
•
Valves closed too much, open valves
•
•
Worn piston cup, rebuild compressor
•
Plugged/frozen tubing, inspect and repair
•
•
Leaky tubing or check valve, inspect and repair
Compressor will not start
•
Wrong voltage, check power source
Compressor will not start
•
Miswired electrical components, check wiring
Diffuser Troubleshooting
Low
High
Uneven Burping
Air Flow
Air Flow
Air Flow
Bubbles Cause and Solution
•
•
Leak in system, check connections and repair
•
•
•
Manifold not set correctly, adjust placement
•
Damaged or torn membrane, replace
•
Compressor issue, see above