background image

6

Maintenance Guidelines

•  Keep your compressor and intake filter clean. Any excess dust and debris 

on motor or air intake may significantly shorten the life of the compressor.

•  Diffusers may need regular cleaning in certain water conditions. This may be 

every two to five years.

•  Compressors may need to be rebuilt if running but no longer “pumping air.” 

Contact your EasyPro dealer for compressor rebuild kits.

•  If lines become frozen, a small amount of denatured alcohol can be run 

down the frozen line to thaw it out. The small amount of alcohol will not 

harm fish or biological processes in your pond.

After one or two years of operation, you will possibly notice a sudden drop in air 

bubbles. This is a sign the compressor needs new diaphrams or vanes. Rebuild 

kits are available to restore like-new performance. Be sure to keep the air filter 

clean. Replacement filters are available.

 Kit 

 

Replacement 

Compressor

  Part # 

Compressor 

Filter/Element 

Repair Kits

  PA10 

DC22 

DC22F 

RK22

  PA12 

DC12 

ERPF1/ERPF12E 

DC12RK

  PA50 

RV33 

AC432/AC393 

RV33V

  PA75 

RV75 

AC432/AC393 

RV75V

  PA100 

RV100 

AC432/AC393 

RV100V

 

Troubleshooting

Compressor Troubleshooting

 Low 

High 

Compressor  Excess

  Pressure  Pressure 

Overheating 

Noise  Cause and Solution

 

• 

 

• 

 

Dirty air filter, clean or replace

 

 

• 

 

 

Valves closed too much, open valves

 

• 

 

 

• 

Worn diaphrams or vanes, rebuild compressor

 

 

• 

 

 

Plugged/frozen tubing, inspect and repair

 

• 

 

 

• 

Leaky tubing or check valve, inspect and repair

 Compressor will not start 

• 

 

Wrong voltage, check power source

 Compressor will not start 

• 

 

Miswired electrical components, check wiring

Diffuser Troubleshooting

 Low 

High 

Uneven  Burping

  Air Flow 

Air Flow 

Air Flow 

Bubbles  Cause and Solution

 

• 

 

• 

 

Leak in system, check connections and repair

 

• 

• 

• 

 

Manifold not set correctly, adjust placement

 

 

 

 

• 

Damaged or torn membrane, replace

 

• 

 

 

 

Compressor issue, see above

Содержание PA10

Страница 1: ...Diaphragm Rotary Vane Aeration Systems Diffused Aeration Systems Installation Operation Maintenance Guidelines Save this booklet for future reference Manuals also available at www easypro com ...

Страница 2: ...ompressors to run 24 hours per day for three to five years The only maintenance required is replacement of wearable items diaphram piston ring vanes etc when needed and keeping filter clean CAUTION All compressors in these kits are designed for oil free operation Never oil or lubricate the compressors In addition to adding oxygen to your pond an aeration system creates a circulation action It take...

Страница 3: ...nstaller and others Aeration System Details Kit Maximum Maximum Diffuser Cabinet Part Pond Size Recommended Depth Assembly Compatibility PA10 1 4 Acre 12 DM2 SC18 SC22 SC25 PA12 1 4 Acre 30 DM2 SC18 SC22 SC25 PA50 2 Acres 18 Two QS2 SC22 SC25 PA75 4 Acres 18 Four QS2 SC22 PA100 6 Acres 18 Six QS2 SC22 Factors such as pond depth and pond shape will affect maximum pond size Replacement 6 rubber memb...

Страница 4: ...or with properly sized tubing Cabinet Placement If installing a Sentinel Deluxe Aeration System place the cabinet on a level unobstructed base to ensure the compressor does not overheat A post mounted cabinet should be kept free from high weeds and other obstructions to ventilation system Diffuser Placement The amount of surface area an aeration system will effectively cover is greatly dependent o...

Страница 5: ...PA10 and PA12 systems are a single line with no valve See images for reference of your system 4a For PA10 style kits 1 20 hp DC22 Compressor 4b For PA12 style kits 1 8 hp DC12 Compressor 4c For PA50 75 100 style kits 1 4 3 4 and 1 hp Rotary Vane Compressors 5 Unroll the entire roll of tubing It is recommended that the diffuser be installed at this point This will allow you to trim any unused tubin...

Страница 6: ...ormance Be sure to keep the air filter clean Replacement filters are available Kit Replacement Compressor Part Compressor Filter Element Repair Kits PA10 DC22 DC22F RK22 PA12 DC12 ERPF1 ERPF12E DC12RK PA50 RV33 AC432 AC393 RV33V PA75 RV75 AC432 AC393 RV75V PA100 RV100 AC432 AC393 RV100V Troubleshooting Compressor Troubleshooting Low High Compressor Excess Pressure Pressure Overheating Noise Cause ...

Страница 7: ...t or parts covered under this warranty Making a Claim A Return Authorization RA number must first be obtained by calling EasyPro at 800 448 3873 or via email at warranty easypro com It is the purchaser s responsibility to pay the return shipping charges Be sure to include the RA number original receipt in the form of an invoice or sales receipt your name your return address and your phone number i...

Страница 8: ...eria is designed to Reduce oxygen demand and sludge buildup Eliminate excess nutrients and pond odors Improve water clarity Available in 10 lb and 25 lb pails with 8 oz water soluble packs or loose powder in 25 lb pails and 100 lb drums EasyPro Sludge Remover Pellets Bacteria specifically designed to reduce sludge on the pond bottom Great for spot treating around docks and beach areas Available in...

Отзывы: