PUMP END ASSEMBLY

1.  Clean and inspect all pump parts (0-ring, seal seats, motor shaft, etc.).
2.  Apply sealant to the bracket bore ID wall and around the seal case - follow sealant mfg. instructions. We recommend using Gasgacinch

®

.  Silicone   

sealant can also be used. 

3.  Press carbon graphite seal into bracket while taking care not to damage carbon graphite face.
4.  Place slinger (rubber washer) over motor shaft and mount bracket to motor.
5.  Carefully, lubricate the seal seat elastomer OD and impeller hub ID with water. Press the seal seat into the impeller hub making certain that the 

ceramic is in evenly - the sealing surface should be parallel with the impeller hub.

6.  Carefully lubricate carbon-graphite and ceramic sealing surfaces with CLEAN water. Do not use silicon lubricants or grease!

7.  Assemble bracket to motor with four M-bolts
8.  Thread impeller onto shaft and tighten! If required, remove motor end-cap and use a screwdriver on the back of motor shaft to prevent shaft rotation 

while tightening. Replace motor end cap.

9.  Seat large O-ring in volute slot and assemble volute to bracket with seven 1/4-20 x 2

3

/

4

" hex cap screws, washers and nuts. Tighten in a cross 

pattern (30 in-lbf). 

10. Install drain plug with its O-ring in volute drain hole.

11. Before operating pump, allow a proper cure time for the sealant used in step 2.        

DISASSEMBLY

1.  Shut off power to motor before disconnecting any electrical wiring from the back of the motor.
2.  Disassemble volute from bracket by removing the seven 

1

/

4

" - 20 threads per inch  x  2

3

/

4

" hex cap screws.

3.  Remove cap covering shaft at back of motor and with a large screwdriver, prevent shaft rotation while unscrewing impeller.

4.  Remove ceramic piece from impeller. (If you are replacing the seal)

5.  Detach bracket from motor.
6.  Remove carbon-graphite seal from bracket by pressing out from the back. Do not dig out from the front! (If you are replacing the seal) 

DESCRIPTION

PART NUMBER

DRAIN PLUG

1000.110

O-RING, DRAIN PLUG

E014B70

VOLUTE

1000.070P

LARGE O-RING

1000.061

IMPELLER

1000.05__*

SEAL - BRASS

1000.0415

SEAL - SS316

1000.0414

SEAL-FOR POWER SERIES 1000.0411

BRACKET

1000.030P

SLINGER

1000.010V

HARDWARE KIT

1000.502

Note: These part numbers are only for stan

-

dard models within the EX8500 and EX11000 

*1000.05__ Reference page one for Impeller 

numbers.

VOLUTE

IMPELLER

WASHER &

LOCK NUT

BRACKET

M BOLT

LARGE

O-RING

SEAL

P-BOLT

& WASHER

DRAIN PLUG

& O-RING

SLINGER

2.75

3.50

7.54

2.00

Motor illustration is for reference only.

1

/

2

" FNPT

Содержание EX8500

Страница 1: ...ut the warranty registration card in this manual EX8500 S N XXXX XXXXXX EasyPro Model EX8500 EX11000 INLET 11 2 11 2 DISCHARGE 11 2 11 2 MAX FLOW gph 8500 11000 MAX HEAD feet 55 72 MAX POWER watts 1385 2056 MAX CURRENT amps 5 38 230v 8 58 230v VOLTS 115 230 115 230 MOTOR HP 11 2 2 MOTOR TYPE 56J 56J MOTOR ENCLOSURE TEFC TEFC IMPELLER 6T 3 85 7T 4 21 TYPE STRAIGHT CENTRIFUGAL MOTOR NEMA C Face 56J ...

Страница 2: ...ALLATION Please read carefully When properly installed this pump will provide dependable trouble free service 1 Locate the pump as near the water source as possible A flooded suction situation is preferred The pump is not self priming therefore if the fluid level is below the pump a swing check valve must be installed and the pump primed prior to start up Figure 2 2 Mount motor base to a secure im...

Страница 3: ...th seven 1 4 20 x 23 4 hex cap screws washers and nuts Tighten in a cross pattern 30 in lbf 10 Install drain plug with its O ring in volute drain hole 11 Before operating pump allow a proper cure time for the sealant used in step 2 DISASSEMBLY 1 Shut off power to motor before disconnecting any electrical wiring from the back of the motor 2 Disassemble volute from bracket by removing the seven 1 4 ...

Страница 4: ...demark of Porter Manufacturing Noryl is a registered trademark of the General Electric Company Teflon is a registered trademark of DuPont Company Activate your warranty by filling out this form and mailing to EasyPro Pond Products 7711 10 19 EasyPro Pond Products Limited Warranty EasyPro Pond Products EasyPro warrants to the purchaser that this product Product will be free from any mechanical or m...

Отзывы: