INSTALLATION

Please read carefully! When properly installed this pump will provide dependable trouble-free service.
1.  Locate the pump as near the water source as possible. A fl ooded suction situation is preferred. The pump is not self-priming, therefore, if the fl uid 

level is below the pump, a swing check valve must be installed and the pump primed prior to start-up. (Figure 2)

2.  Mount motor base to a secure, immobile foundation.
3. Use only plastic fi ttings on both the intake and discharge ports. Seal pipe connections with Tefl on™ paste. These fi ttings should be self-supported 

and in neutral alignment with each port. (i.e. Fittings must not be forced into alignment which may cause premature line failure or damage to the 
pump volute.) For non-fl ooded installations, a strainer basket and check valve are recommended.

4.  Never restrict the intake. Keep both input and discharge lines as free of elbows and valves as possible. Always use pipe of adequate diameter. This 

will reduce friction losses and maximize output.

5.  This pump is not self-priming! It must not be run dry! We recommend a fl ooded suction installation. Please read carefully! When properly installed, 

the pump will provide dependable, trouble-free service.

ELECTRICAL HOOK-UP

1.  Check that supply voltages match the motor’s requirements.
2.  Check motor wiring and connect, according to instructions on motor, to match supply voltage. 
3.  Power cord should be protected by conduit or by cable and be of proper gauge. It should be no longer than necessary.
4.  Power should be drawn directly from a box with circuit breaker protection or with a fused disconnect switch.

We congratulate you on your choice of the EX Self Priming Pump! It has been carefully designed using the advantages of today’s technol-
ogy and carefully constructed to give you the dependability of yesterday. To insure proper performance, we urge you to carefully follow 
the instructions in this manual. If you have any questions, call your nearest distributor or EasyPro for assistance.

PUMP

SWING CHECK 

VALVE

FLOODED SUCTION

WARNING: DO NOT RUN DRY!

WARNING: ALWAYS SHUT OFF ELECTRICAL POWER BEFORE INSTALLATION AND / OR SERVICING THIS PUMP! ALL 
ELECTRICAL WIRING SHOULD MEET STATE AND LOCAL ORDINANCES. IMPROPER WIRING MAY NOT ONLY BE A 
SAFETY HAZARD BUT MAY PERMANENTLY DAMAGE THE MOTOR AND/OR PUMP! 

BALL 

VALVE

(FIGURE 2)

Содержание EX6750-2

Страница 1: ...ill out the warranty registration card in this manual S N XXXX XXXXXX EX6750 2 EasyPro TYPE STRAIGHT CENTRIFUGAL MOTOR NEMA C Face 56J HORSEPOWER 2 1750 RPM 1 5 3450 RPM VOLTAGE 115 ACCESORIES 90 CUBIC INCH STRAINER BASKETS 11 2 2 SWING CHECK VALVES 11 2 2 3 500 CUBIC INCH STRAINER BASKETS 11 2 2 3 MODEL SPEED INLET DISCHARGE MAX FLOW gph MAX HEAD feet MAX POWER watts MAX CURRENT amps volts MOTOR ...

Страница 2: ...is not self priming It must not be run dry We recommend a flooded suction installation Please read carefully When properly installed the pump will provide dependable trouble free service ELECTRICAL HOOK UP 1 Check that supply voltages match the motor s requirements 2 Check motor wiring and connect according to instructions on motor to match supply voltage 3 Power cord should be protected by condui...

Страница 3: ...end cap 9 Seat large O ring in volute slot and assemble volute to bracket with seven 1 4 20 x 2 3 4 hex cap screws washers and nuts Tighten in a cross pat tern 30 in lbf 10 Install drain plug with its O ring in volute drain hole 11 Before operating pump allow a proper cure time for the sealant used in step 2 DISASSEMBLY 1 Shut off power to motor before disconnecting any electrical wiring from the ...

Страница 4: ...ndifanyprovisionshallbedeemedinvalid theremainingprovisionsshallremaininfullforceandeffect 11 Rights under this warranty are not assignable without the express prior consent in writing by EP and regardless of the terms of such consent in writing such assignee shall have no greater rights than his assignor had against EP Symptom Problem Resolution No Flow Insufficient Prime Prime system with water ...

Отзывы: