EasyPro Compact Aeration Series Скачать руководство пользователя страница 2

(800) 448-3873 • Grant, MI 49327

www.easypro.com

9336 • 4/19

6

6.  To remove lid of internal housing, 

squeeze longer sides tightly to create a 

small space for a flat screw driver. Use 

a slight twisting motion with the screw 

driver to release the lid of the internal 

housing.

4.  

 To remove the housing cover, squeeze 

the back section while alternately 

squeezing and pulling the front section 

off.  Use a flat screw driver with a 

twisting motion (avoid prying) to loosen 

front cover and then pull front section off.

4

5

5.  Remove the back cover section 

while carefully guiding the electrical 

connector through the rectangular hole.

7

8

9

9.  Replace the lid of internal housing.

7.  Remove screws from side of internal 

housing to remove diaphragm 

assemblies from unit. Inspect magnets 

and clean if needed.

8.  Remove diaphragm assemblies from 

unit. Remove the black seals shown in 

the inset photo and press them into the 

sides of the new diaphragm assemblies. 

Install new diaphragm assembly by 

holding it securely to the side while 

tightening screw.

12.  Reinstall bottom housing and secure 

with four screws.

10.  Guide electrical connection through the 

hole in back housing cover and reinstall 

front cover.

11,  Reinstall outlet bushings and place 

internal housing into base. Reconnect 

electrical connection.

10

11

12

Troubleshooting

Loss of air output but unit is running:
• 

Check that the flow control is turned up.

• 

Check to make sure lines are not kinked or plugged.

• 

Inspect the air stones to ensure they are clean. Replace or 

clean as necessary.

• 

Inspect diaphragms. Replace as necessary.  

Unit is not running:
• 

The GFCI may have tripped.

Replacement Parts

Air stone: part # CRAS1            Check valve: part # CASCV

Отзывы: