background image

 

 

EasyMax N 

Self-Monitoring Blood Glucose System 

 

 

User’s Manual 

 
 

Please read this User’s Manual thoroughly   

before using your blood glucose meter.

 

 

 

 
 
 
 

Содержание N

Страница 1: ...EasyMax N Self Monitoring Blood Glucose System User s Manual Please read this User s Manual thoroughly before using your blood glucose meter...

Страница 2: ...tion and step by step direction to use the EasyMax N Self Monitoring Blood Glucose System Thanks again for choosing the EasyMax N SMBG System Intended Use The EasyMax N Self Monitoring Blood Glucose T...

Страница 3: ...ork together to measure the amount of glucose in your blood The system includes Blood Glucose Meter Test Strip x 10 ct Normal Control Solution Carrying Case Control Solution Instructions Lancet x 5 ct...

Страница 4: ...p If you have questions or need assistance please call the Customer Care Service toll free at 1 866 203 2761 Eastern Time Mon Fri 9 00AM 9 00PM or E mail info oaktreeint com You can also visit www oak...

Страница 5: ...lting in incorrect reading Disassembling the meter will also void the warranty Always keep the meter clean and store it in a safe place Protect the meter from direct sunlight to ensure a longer lifesp...

Страница 6: ...ts that come in contact with human blood even after cleaning should be handled as if capable of transmitting viral disease Consult with your healthcare professional before testing on your forearm Do n...

Страница 7: ...f you have followed the steps in the user s manual but still have symptoms that don t seem to match your test results or if you have questions please talk to your doctor Please read your test strip in...

Страница 8: ...Test 17 Understanding Control Solution Test Results 19 Chapter 3 Testing Your Blood Glucose 21 Using The Lancing Device 21 Inserting A Lancet into the Lancing Device 22 Running A Blood Glucose Test Wi...

Страница 9: ...38 Setting The Beeper For The Alarm 40 Setting The Clock 41 Chapter 5 Maintenance And Troubleshooting 42 Installing Batteries 42 Cleaning Your Meter 43 Maintenance And Testing 44 Cleaning Your Lancing...

Страница 10: ...Slot To insert test strip or check strip Note When you use software with the meter the symbol of Type will show you how to start operation A Test Records B Transfer data to PC C Apply blood or contro...

Страница 11: ...turn on the meter or read records S Button To turn on the meter or go into Setting Mode Test Strip Bottle A Blood collection area B Reaction area C Hand hold area D Strip insert direction E Electrode...

Страница 12: ...r memory or if you want to download your results to a computer 1 Press and hold the S button until turning the meter on Press S button and release to enter setting mode 2 The time and date appear on t...

Страница 13: ...ield is the one you are setting 6 Press the S button to confirm the setting The display will show SCL and the unit of measurement Press the S button again to go to screen shown in Step 1 Press and hol...

Страница 14: ...e bottle The strip is for single use only Do not reuse it Record the date you open the test strip bottle Be sure to check the Expiration date on the test strip bottle The test strip is good for three...

Страница 15: ...s You should run the control solution test when You use the EasyMax N Blood Glucose Meter for the first time You open a new bottle of test strips You think the meter or test strips may be working inco...

Страница 16: ...ration date on the bottle whichever comes first Do not use a control solution that is past the expiration date The control solution can stain clothing If you spill it wash your clothes with soap and w...

Страница 17: ...ble 3 Remove the control solution bottle cap and wipe the tip of the bottle with a tissue 4 Squeeze the bottle until a tiny drop forms at the tip of the bottle Touch the drop to the Blood collection a...

Страница 18: ...y Don t remove the test strip yet Check if the reading falls within the range printed on the test strip bottle 6 Remove the test strip and throw it away after you have compared the reading to the rang...

Страница 19: ...solution result is inside the range on the test strip bottle your test strips and your meter are working properly If your control solution result is not inside the acceptable range printed on your te...

Страница 20: ...er 2 9 Is the control solution expired or contaminated Replace with new control solution to check the performance of SMBG system 9 Were test strips and control solutions stored in cool dry places Repe...

Страница 21: ...t for you Please do not share your lancing device with anyone And always use a new sterile lancet Lancets are for one time use only Note Used test strips and lancets are considered bio hazardous waste...

Страница 22: ...Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing device firmly then twist off the pr...

Страница 23: ...23 3 Recap the front cap 4 Select the desired penetration depth Note Select 1 3 for soft or thin skin 4 5 for average 6 8 for thick or calloused skin...

Страница 24: ...iding barrel of the lancing device until it clicks and then release Now the lancing device is ready Do not prick your finger until your meter and strip are prepared 6 Set the lancing device aside unti...

Страница 25: ...oroughly 2 Put a test strip into the meter in the direction of the arrow The meter will automatically turn on 3 Please wait at least 5 seconds until the intended area is dry and clean before sampling...

Страница 26: ...his helps you get a blood drop Touch the blood drop to the tip of the transparent window of the test strip Do not put blood on top of the strip Be sure to get enough blood on the strip s reaction zone...

Страница 27: ...meal or fasting state more than 2 hours since the last meal Two hours or more after taking insulin Two hours or more after exercise Do NOT use AST if You think your blood glucose is low You are unawar...

Страница 28: ...e your treatment just because of a result If the blood glucose test result does not match how you feel do a fingertip test to confirm the result again If you often do not notice when your blood glucos...

Страница 29: ...able tip against the forearm 3 Press the trigger button to activate the lancing device Hold the device against forearm and increase pressure until the blood sample size is sufficient Running A Blood G...

Страница 30: ...he adjustable cap 2 Without touching the used lancet stick the lancet tip into its protective cover Grip the lancet carrier firmly and pull the lancet safely out 3 Discard the used disposable lancet i...

Страница 31: ...ur test result doesn t match the way you feel please follow these steps 1 Run a control solution test Chapter 2 Control Solution Testing 2 Repeat a blood glucose test Chapter 3 Testing Your Blood gluc...

Страница 32: ...reater than 240 mg dL and you have symptoms of high blood glucose contact your healthcare professional instantly If the result does not match how you feel follow the steps under Unusual Test Results W...

Страница 33: ...t just means that time has elapsed and your blood glucose has changed If you want to compare your meter result to the lab result you must be fasting Bring your meter to the doctor s office and test yo...

Страница 34: ...Note 1 Do not change your therapy based on one individual result in memory 2 The memory is not lost when you replace the battery You do need to check that the time and date are still correct See Sect...

Страница 35: ...s in order from the most recent to the oldest 4 To delete a test result Press and hold M for more than 3 seconds The display will show dEL 5 Continue pressing M without releasing the currently viewed...

Страница 36: ...lize your meter to suit your needs Here are the features you can customize Time and Date to set the time and date see Chapter 1 Thermometer to show the current temperature Alarm as a reminder to test...

Страница 37: ...the M and S buttons at the same time and hold for more than 3 seconds The meter will go into Centigrade Thermometer Mode 3 Press the S and the meter will change the temperature reading to Fahrenheit 4...

Страница 38: ...icators appear at the upper left corner of the display screen 2 Press the S when the display shows OFF to change the meter alarm mode to Beep Setting Mode 3 Press the S when the display shows On the f...

Страница 39: ...etting 6 And then you can establish other alarms that you would like Please repeat steps 2 to 5 and finally press S to confirm the setting till in to Beep Setting Mode As the following page shows 7 If...

Страница 40: ...40 Setting The Beeper For The Alarm 1 You will see the Beep Setting Mode after the Alarm Setting was confirmed Press the M to switch the On OFF at the center of the display 2 Press the S to confirm...

Страница 41: ...he month field and 2 digits for the day field at the top left corner and 2 digits for the hour field and 2 digits for the minute field at the top right corner 2 The meter alarm will sound when clock t...

Страница 42: ...n the display The meter will not turn on the first time batteries are installed Please press and hold S button or insert the test strip to turn your meter on The meter will turn off automatically Or y...

Страница 43: ...stains Follow these guidelines carefully to help you get the best performance possible Do Not Get any moisture in the test strip slot Spray any cleaning solution directly onto the meter Put the meter...

Страница 44: ...display All the indicators should be clear and look exactly like the picture to the left If not call the Customer Care Service Center toll free 1 866 203 2761 Eastern Time Mon Fri 9 00AM 9 00PM or E...

Страница 45: ...e any concerns please contact your local dealer Humidified Used strips Action Replace with a new strip Low power Action Replace with new batteries System fault Action Replace the batteries first If 00...

Страница 46: ...ain If the result is still the same try a control solution test and if the control solution test falls within the correct range then please contact your healthcare professional The test result is lowe...

Страница 47: ...test continues Action Relocate the meter to a location with temperature between 50 F 104 F 10 C 40 C The Lt and thermometer icon appears Temperature is too low outside the required range of 50 F 104...

Страница 48: ...10 C 40 C Operating condition Relative Humidity R H 90 0 6 L Blood sample Fresh blood from fingertip or forearm Hematocrit Hct 30 55 Power 2 Alkaline 1 5V AAA Battery life Over 2000 tests Display dime...

Страница 49: ...tocrit above 55 may cause lower results If you do not know your hematocrit level please consult with your healthcare professional 6 Altitude up to 10000 feet above sea level has no effect on readings...

Страница 50: ...nces up to the test concentration will not affect the test results Interfering Substance Test Concentration mg dL Bias at 50 5 mg dL Bias at 250 5 mg dL Bias at 500 5 mg dL Acetaminophen 8 10 2 6 5 3...

Страница 51: ...an Diabetes Association Standards of Medical Care for Patients with Diabetes Mellitus Diabetes Care 25 2002 p S37 Manufacturer 2F No 49 2 Lane 2 Guang Fu Rd Sec 2 Hsinchu City Taiwan Lancing Device Me...

Страница 52: ...1 923 4331 E mail saehan saehanmed com Warranty EPS warrants the original purchaser for a period of 5 years from the date of purchase This means during the warranty period if your Self Monitoring Bloo...

Отзывы: