background image

Green double flash

Every 20 seconds: logger full, no alarm

Green single flash 

Every 30 seconds: delayed start
Every 20 seconds: low battery, logging, no alarm
Every 10 seonds: logging, no alarm

Red/Green single flash 

Every 20 seconds: logger full, last value equal to or 
exceeds the low or high alarm

Red double flash 

Every 10 seconds: logging, high alarm
Every 20 seconds: logging, high alarm, low battery

Red single flash 

Every 10 seconds: logging, low alarm
Every 20 seconds: logging, low alarm, low battery

No LEDs flash 

LEDs disabled during configuration to save battery 

power and increase logging life /logger stopped / 
battery empty

EL-USB-1-LCD, EL-USB-1-RCG, EL-USB-3, 

EL-USB-4, EL-USB-TC & EL-USB-TC-LCD

Green double flash 

Delayed start 

Red double flash

High alarm

Orange double/single flash 

  

Memory full

EL-USB-1

EL-USB-2, EL-USB-2+, EL-USB-2-LCD

EL-USB-2-LCD+

LED FLASHING MODES

SPECIFICATIONS

Green triple flash

  

Logger full, no alarm on the channel

Red triple flash 

      

Logger full, alarm on the channel

Green double flash  

                 

Delayed start

Green single flash

  

Logging, no alarm

Red single flash 

  

Logging, low alarm on the channel

Red double flash

 

Logging, high alarm on the channel

No LEDs flash 

 

  

Logger stopped or battery empty 

Dual Red Flash

Battery low

*Depending on logging rate, ambient temperature, and use of alarm LED

LCD INDICATORS 

(EL-USB-1-LCD, EL-USB-2-LCD, EL-USB-2-LCD+ AND EL-USB-TC-LCD ONLY)

Temperature 

scale

Relative Humidity 

symbol*

Minimum logged 
value symbol

Maximum logged 
value symbol

Reading 

Negative symbol

Temperature scale symbols

Maximum/Minimum 
logged value symbol

LCD INDICATION

 

Display 

     Logger Status                  

Explanation

Delayed Start

Push to Start

Logging

Stopped

This is shown when the logger is set to 

start at a specific data and time*

This is shown when the logger is setup
for “Push to start” logging

This is shown when the logger is running 
in “LCD off” mode, and the button is 
pressed. The display clears again after
three seconds

If the logger has not been set to log and
the button is pressed, three dashes are 
displayed for three seconds

* If the logger is set to “LCD off” or “LCD on for 30 seconds” mode, then this will only be shown after the 
   button is pressed. Otherwise the display will remain blank.

DISPLAY AND STATUS FUNCTIONS

LCD INDICATION

EL-USB-1-LCD, EL-USB-2-LCD &

EL-USB-2-LCD+

EL-USB-TC-LCD

Part No

Function

Range

Accuracy (overall error)
Typ.                    Max.

Readings

Battery

Battery Life*

EL-USB-1

Temperature

-35 to +80°C (-31 to +176°F)

±1ºC (±2ºF)

16,382

3.6V ½AA

1 year

EL-USB-1-LCD

Temperature with LCD

-35 to +80°C (-31 to +176°F)

±0.5ºC (±1ºF)

±1.5

ºC

 (±3

ºF

)

16,382

3.6V ½AA

1 year

EL-USB-1-PRO

Extended Temperature

-40 to +125°C (-40 to +257°F)

±0.2ºC (±0.4ºF)

32,510

3.6V 

AA

3 years

EL-USB-1-RCG

Temperature with rechargeable 
battery

-20 to +60°C (-4 to +140°F)

±1ºC (±2ºF)

32,510

Lithium Ion

1 month 
(rechargeable)

EL-USB-2

Temperature, Humidity & Dew Point

-35 to +80°C (-31 to +176°F)

0 to 100%RH

±0.5ºC (±1ºF)

±3%RH

±2ºC (±4ºF)

±5.0%RH

16,382

16,382

3.6V ½AA

1 year

EL-USB-2+

Increased Accuracy Temperature, 
Humidity & Dew Point

-35 to +80°C (-31 to +176°F)

0 to 100%RH

±0.3ºC (±0.6ºF)

±2.0%RH

±1.5ºC (±3ºF)

±4.0%RH

16,382

16,382

3.6V ½AA

1 year

EL-USB-2-LCD

Temperature, Humidity and Dew 
Point with LCD

-35 to +80°C (-31 to +176°F)

0 to 100%RH

±0.5ºC (±1ºF)

±3.0%RH

±2ºC (±4ºF)

±5.0%RH

16,382

16,382

3.6V ½AA

1 year

EL-USB-2-LCD+

Increased Accuracy Temperature, 
Humidity and Dew Point with LCD

-35 to +80°C (-31 to +176°F)

0 to 100%RH

±0.3ºC (±0.6ºF)

±2.0%RH

±1.5ºC (±3ºF)

±4.0%RH

16,382

16,382

3.6V ½AA

1 year

EL-USB-3

Voltage

0 to 30V d.c.

±1%

32,510

3.6V ½AA

1 year

EL-USB-4

Current Loop

4 to 20mA

±1%

32,510

3.6V ½AA

1 year

EL-USB-5

Counter, Event & State

N/A

±3 secs/24 hrs

32,510

3.6V ½AA

1 year

EL-USB-CO

Carbon Monoxide

0 to 1000ppm  

 

NOT A LIFE SAVING DEVICE

±6ppm

32,510

3.6V ½AA

3 months

EL-USB-CO300

Carbon Monoxide

0 to 300ppm     

NOT A LIFE SAVING DEVICE

±4ppm

32,510

3.6V ½AA

3 months

EL-USB-TC

Thermocouple (J, K and T-type)
K-type probe included

-200 to +1350ºC (-328 to +2462ºF) (K-type)
-200 to +1190ºC (-328 to +2174ºF)  (J-type)
-200 to +390ºC (-328 to +734ºF) (T-type)

±1ºC (±2ºF)

±2ºC (±4ºF)

32,510

3.6V ½AA

6 months

EL-USB-TC-LCD

Thermocouple with LCD 
(J, K and T-type)
K-type probe included

-200 to +1350ºC (-328 to +2462ºF) (K-type)
-200 to +1190ºC (-328 to +2174ºF)  (J-type)
-200 to +390ºC (-328 to +734ºF) (T-type)  

±1ºC (±2ºF)

±2ºC (±4ºF)

32,510

3.6V ½AA

6 months

EL-USB-5

Green single flash 

Every 10 seconds: normal logging

Green single flash 

Every 20 seconds: low battery

Green double flash 

Every 20 seconds: memory full

Red single flash 

Event/State change/Count recorded

*EL-USB-2-LCD & EL-USB-2-LCD+ only

Green single flash

Logging, no alarm

Red single flash 

 

    

Low alarm

Orange single flash every 60 sec       

 

Low battery

No LEDs flash 

Logger stopped or battery empty