Simplified Setup Guide for PXBKB Keypad

 

 

 

 

 

 
 

Setting Relay 1’s time – 0 – 99 Seconds: 

 

Enter the admin mode by keying in the admin code twice (the yellow LED should be solid). Press 

 

then 

 

(the yellow LED should be flashing).Then key in the 2 digits which represent the 

seconds the relay will hold open / closed for. I.E. ‘05’ for 5 seconds. If you want the relay to latch 
open / closed then enter ‘00’ (this mode will require you to enter the user code in to open the 
relay and then a second time to close the relay). 

 

Press the # to exit the programming mode. 

 

 

Restore Keypad back to Factory Settings: 

 

Enter the admin mode by keying in the admin code twice (the yellow LED should be solid). Press 

 then

 (the yellow LED should be flashing). Next press 

 

twice. You should hear a single 

resonating beep 

. This indicates that all user codes have been cleared. 

 

Next press 

 

then 

 

(the yellow LED should be flashing) and press 

 

twice. You should hear 

another single resonating beep 

. This indicates that all settings have been restore back to 

factory values. 

 
 

 

Press the # to exit the programming mode. 

 

 
 
 
 

Wiring 
Diagram: 