Figure 5
Figure 6
Figure 7
Figure 8
Removing the brush caps:
Using a small flat blade screw driver
remove one brush cap at a time. Care should be taken as the brush
holder has a spring that forces to the brush onto the armature. This
spring may cause
the cap to pop out
unless held firmly
(Figure 5
).
Removing and
dressing the
brush:
Remove the
brush from the
holder by lifting up
and sliding the brush and spring clear
(Figure 5)
. Once the brush is
clear hold the brush base and carefully take a couple of swipes across
the brush face with fine sand paper
(Figure 6).
NOTE: WHEN SANDING THE FACE OF THE BRUSH DO NOT
REMOVE ANY MATERIAL. WE ARE ONLY SCUFFING THE
SURFACE TO ALLOW FOR BETTER BRUSH CONTACT.
Reinstalling the brush:
Insert the brush back into the holder. Hold the
terminal tab into the holder. Carefully insert the cap and turn with a
small flat bladed screw driver.
Use care not to cross thread the cap.
Once the cap is threaded lightly tighten against terminal tab
(Figure 7)
.
Repeat service on lower brush.
Assembly:
Reconnect motor
wires to red and
black terminals.
Check fan blade for
bent blades by
spinning by hand. If
blades are not
aligned carefully
bend back into
place.
Carefully reinstall upper rear panel
(Figure 8)
.
After completing the installation of the rear panel and tightening all the
phillips screws. Plug the heater back into AC power and test run by
running fan motor on “Fan” setting for 2 minutes and then running on “Clean” for 30 seconds. Open hopper lid and run unit
through a beginning start up by pressing “Low” and allowing fan to ignitor and fan to start up. If all appears to activate
reinstall unit.
Additional information is available on line@ www.sierraproductsinc.net
Technical Customer Service - 775-241-2586
63 Laxalt Dr. Carson City, NV 89706
775-241-2586 Fax 775-241-2704
www.sierraproductsinc.net
P/N Fan Motor Brush Service 08 10/08
22
Содержание EF3801B
Страница 8: ...Trouble Shooting Flow Chart 1 Stove not running at all 8 ...
Страница 13: ...Trouble Shooting Flow Chart 12 Fan speed erratic Surges 13 ...
Страница 18: ...18 ...
Страница 27: ...Pre 2004 Pellet Stove Wiring Detail Sierra Products Inc 63 Laxalt Dr Carson City NV 89706 P N 140804 10 07 27 ...
Страница 28: ...2005 HARNESS WIRING DETAIL Sierra Products Inc 63 Laxalt Dr Carson City NV 89706 P N 140804 10 07 28 ...
Страница 31: ...63 Laxalt Dr Carson City NV 89706 775 241 2586 Fax 775 241 2704 www sierraproductsinc com 31 ...