background image

symbols in sequence: 188.8°F/°C, the last measurement (if the last temperature
is lower than 89.6°F /32.0°C, it will be a Lo°F/Lo°C), the default setting
temperature 98.6°F or 37 °C, then the current temperature of the flexible tip
with a flickering °F/°C (if the ambient temperature is lower than 89.6°F /32.0°C,
it will be a Lo with a flickering °F/°C) to indicate you are ready to test.

NOTE

The Lo with a flickering °F/°C is not an indication of low battery. 

A true low battery symbol is an empty flickering battery. When the
environment or ambient temperature is higher than 109.2°F(42.9°C), LCD
will display Hi °F(Hi °C), in this case, you may need to wait till the temperature
is lower than 109.2°F(42.9°C) to take. 
 

Use  alcohol  to  disinfect  the  probe  then  choose  the  method  you  prefer  to 
measure:

3.

Oral use: Place the probe under tongue and close the mouth for approximately
25  seconds  to  finish  a  measurement.  Normal  temperature  range  for  an 
adult is 97.3 º F~98.9 º F (36.3°C ~37.2°C), as it applies to an oral read. 

3.1.

when “           ” symbol flash in the corner of the display screen.   

Axillary use: Wipe armpit with dry towel then place the probe in armpit firmly 
for approximately 25~37 seconds to finish a measurement. Normal temperature

3.2.

Use a non-metal pointed tool to remove the battery
and insert the new battery with the positive (+) side facing up.
Carefully slide the battery cover back into place.

Notes:

Rectal use: Lubricate the probe with water-soluble jelly such as K-Y
jelly. Do not use petroleum jelly like Vaseline for easier insertion because this 
will adversely affect the accuracy of the result. Insert the probe into rectum 
about 1/2 inch at most (

ensure not too deep to avoid injury

) for about 25

seconds  to  complete  the  measurement.  Normal  temperature  range  for  an 
adult is 97.7 ºF ~99.8 ºF (36.5°C ~37.7°C), as it applies to rectal read.
A "Bi Bi Bi" alarm will sound a total of ten times indicating the completion of the
temperature in the normal range.
The power will be shut off automatically if there is no temperature rising for 10 
minutes.
Replace the battery 

Suitable for EMT-021
The battery in your Easy@Home digital thermometer needs to be replaced 

To replace the battery
Push or slide the battery cover away from the unit.

3.3.

4.

4.1.

5.

5.1.

5.1.1.

5.1.2.

5.1.3.

range for an adult is 96.8 ˚F  ~98.6 ˚F  (36°C~ 37°C), as it applies to an
auxiliary read.

Reading Display

Celsius Display

1. It is suggested to stay with the same measurement method. This means

    especially not take oral or armpit measurements after taking rectum 

    temperatures for hygienic reasons.

2. Press the power button for approximately 10 seconds until the unit flickers

    in the shutdown state. Then, release the power key and then quickly press

    the power key again for a short time to switch between Fahrenheit and

    Celsius. Finally, turn the power button off and then back on, and the switch

    is successful.

Low Battery Indicator

Fahrenheit Display

Definition of Display Symbols

6.

This thermometer is guaranteed for 1 year from the purchasing date under
normal use. The warranty does not cover the damage of improper use or the
battery running out.

Note: 
Any solution, dilution or methods other than mentioned above might
cause reliability problems with the thermometer.

Users should measure, change batteries under normal circumstances, and maintain 
the device and its accessories according to the user manual.

WARNINGS

LIMITED WARRANTY

Do not perform maintenance while the thermometer is in use.
The device is not for use in an OXYGEN-RICH ENVIRONMENT.
Before each  use, check the device. Do not use a damaged device or device with
damaged electrical wiring. The continuous use of a damaged unit may cause
inaccurate results or bodily injury.

If  you  have  any  inquires  or  concerns  about  the  device,  such  as  setting  up, 
maintaining or using it, please contact our Customer Service Team.
Do not open or repair the device by yourself.
The main material of the case is ABS. Be cautious of potential allergic reactions to 
this materials.

The  typical  service  life  of  an  unused  new  battery  is  100  hours  continuous 
operation.  
Protection against electric shock: built-in powered ME equipment.
Protection against harmful ingress of water or particulates: IP22. 

1.
2.
3.

4.

5.
6.

7.

8.
9.

Qu

es�o

ns 

o

r c

o

mments?

please call toll-free: 

1-855-822-6999 M-F 9 a.m.-5 p.m. CST 

E-mail:[email protected]

Easy Healthcare Corpora�on

360 Shore Dr.Burr Ridge,IL USA 60527

PRECAUTIONS

Do not bite, bend or dismantle the thermometer.

Keep the device out of the reach of children/pets to avoid inhalation or swallowing 
of small parts. 
Do not expose the device to direct sunlight, high temperature or moisture.
Do not sterilize the device. Prevent saliva or cleaning solution from penetrating the 
display window.
Clean the thermometer before and after use with soft cloth and a cleaning solution 
and store in the plastic case. It is recommended to wipe with an alcohol pad for 
home use.
If the LCD display shows the low battery symbol or is not a clear visual as usual, 
it means the battery may be running out. Please be sure to replace the battery 
before next use in this case.

2.

3.
4.

5.

6.

Отзывы: