Rough align
When making a new installation, a rough alignment can be necessary. Place the Measuring units on the rods, make
sure they are at the approximately same rotational angle and radius. Also make sure that the adjustment knob is
adjustable in both directions.
1. Place the Measuring units at 9 o’clock. Adjust the laser
line to the center of both targets. Use the adjustment
knob and/or move the detectors on the rods.
2. Turn the shafts 180º. Make a mark on the rods or
machine halfway between the laser line and center of
both targets.
3. Adjust the laser beams half way to the center of tar-
gets. Use the adjustment knobs and/or move the
detectors on the rods.
4. Adjust the movable machine until the laser beam hits
the center of both targets.
5. Turn the shafts 180º. Check if both laser lines hit the
targets. If not, repeat step 3–5.
Turn shafts to 12 o’clock. Repeat all steps for vertical
adjustment.
35
HORIZONTAL
Содержание XT11
Страница 1: ...User Manual English 05 0835 EN Revision 2 0 User Manual last built 9 12 2017...
Страница 2: ......
Страница 6: ...This page intentionally left blank to ensure new chapters start on right odd number pages...
Страница 32: ...32...
Страница 58: ...A Offset B Angular C Both offset and angular misalignment 58 BELT...
Страница 65: ...A Misaligned sheave B Aligned sheave the laser beam disappears in the slot of the target 65 BELT...
Страница 74: ...Part No 12 0985 Camera removed from XT11 74 TECHNICAL DATA...
Страница 76: ...Part No 12 0968 IR Camera added to XT11 Part No 12 0985 Camera removed from XT11 76 TECHNICAL DATA...