ELECTRICAL CONNECTION

1. 

The 3 phase wiring connections are made at the Upper Terminals of the 
Electrical Box 

(FIG 8)

.

2. 

The Scroll Compressor features a microprocessor in the control unit 
Control Panel Display which will detect incorrect phasing and will display 
“ALARM1:” “PHASE REVERSE” and an audible alarm will sound. 

3. 

If these conditions occur, it is an indication that the 3 Phase connections 
have been done incorrectly. To correct, shut off power at main breaker 
disconnect switch and revise the connection sequence of the three phase 
upper terminals of the Electrical Box 

(FIG 11)

.

4. 

Press the SET Button          to cancel alarm and reset the Error message in 
the LCD Display window.

FIG. 8

 

  The 3 phase wiring connections MUST be done in the proper 

sequence or the motor could possibly run in reverse which 
could cause severe and permanent damage to the Scroll.

3 PHASE REQUIREMENTS

•  208-240V, 60Hz, 22-amp, 3 phase voltage and amperage requirements. All wiring must be done by a licensed electrician, in accordance with 

National Electric Code and state and local requirements. For best performance, the Compressor must be installed on a dedicated circuit, with 
circuit breaker or fuse protection. Each time the Compressor motor starts, it will momentarily draw several times its full load amperage.  
It is important to consider this start-up surge when specifying circuit breakers or fuses. If fuses are used, time-delay type must be installed.

•  The voltage variation between the rated input voltage requirements and that of the actual input voltage supply must not /- 10%.  

If greater variation exists, a step-up or step down transformer must be installed.

•  The voltage variation between legs of the 3-phase supply must be within 5%. If greater variation exists, a voltage regulator or rectifier must  

be used.

•  The power supply wiring must be adequately sized to prevent dangerous overheating and low voltage at the Compressor during startup and 

running. Low voltage will cause difficult starting, overheating, and excessive tripping of circuit breakers. The wire gauge must be increased for 
longer wire runs to accommodate the increased resistance inherent in longer runs. Refer to the National Electric Code to determine the proper 
wire gauge for your wire run length. Low voltage can also be caused by low supply voltage from the power company, or from other equipment 
running on the same line.

•  For safety reasons, install a main breaker disconnect switch in the line from the electrical panel to the Compressor within momentary reach 

of the Compressor. When the switch is off, all power to the Compressor is disconnected. When the switch is on, the compressor will start and 
stop automatically as it will be controlled by the pressure switch.

S

Содержание QST-80

Страница 1: ...QST 80 120 SCROLL COMPRESSOR INSTRUCTIONS Item 32500...

Страница 2: ...eliability and longer life CONTENTS 1 QST 80 120 Scroll Compressor 1 3 4 x 3 3 8 Pipe Nipple 1 Side Panel Key 1 Eastwood Instruction Manual SPECIFICATIONS Power Requirement 208 240V 60Hz 31 0 amp 3 ph...

Страница 3: ...e compressor is not in use Do not use the unit with the Cover removed Serious injury could occur from contact with moving parts Never direct high pressure airstream to exposed flesh This compressor mu...

Страница 4: ...hase COMPRESSOR SITE LOCATION The Eastwood Elite QST 80 120 Scroll Compressor must be located in an indoor area on a firm clean level surface A solid level concrete floor is best Select an area with a...

Страница 5: ...the latches FIG 1 Front and rear panels have 2 latches each and are released by turning the key 1 4 of a turn to the respective outside corner End panels have one latch each and are released with 1 4...

Страница 6: ...close tolerances Check that the Cover on the Air Filter is latched correctly and hasn t vibrated loose in shipment The two molded in arrows on the base and lid should be aligned FIG 7 AIR LINE CONNEC...

Страница 7: ...entarily draw several times its full load amperage It is important to consider this start up surge when specifying circuit breakers or fuses If fuses are used time delay type must be installed The vol...

Страница 8: ...on Scrolls Down in Menu Selections E Up Menu Button Scrolls Up in Menu Selections F Selection to Right Button Enables option selection Moves cursor position right G Return Button Exit Menu Page or ret...

Страница 9: ...ep 1 6 If correct rotation of the Motor has been verified proceed to COMPRESSOR OPERATION FIG 10 FIG 11 COMPRESSOR OPERATION Depress the START Button of the Control Panel FIG 9 Allow the Tank pressure...

Страница 10: ...re at Scroll output may read higher than Gauge Pressure visible at the side of the unit Press 2nd time Displays Scroll Air Temperature FIG 15 Press Again Toggles between Air Pressure and Air Temperatu...

Страница 11: ...splays PROD DATE FIG 28 Build date of unit Press Displays SERIAL FIG 29 Serial of unit Press Displays C STATE RX TX FIG 30 This is a manufacturer only check point setting used for calibration purposes...

Страница 12: ...for a short period At this point all work demands of the Compressor should be stopped immediately and the Compressor housing should be checked for blockage of cooling air side vent panels or blockage...

Страница 13: ...arator Oil Reservoir FF Oil Drain Valve GG Oil Level Sight Gauge HH Oil Fill Port JJ Air Pressure Gauge KK Oil Temperature Sensor LL Pressure Safety Release Valve MM Pressure Sensor NN Compressed Air...

Страница 14: ...S 33 34 a FU1 FU2 FU3 Motor Fan Fuses Upper Motor Connections Lower Fan Connections b QF1 Fan Pressure Switch c QF2 Unloading Valve Pressure Switch d KMF Fan Contactor e KM1 Motor Contactor f Transfor...

Страница 15: ...ure daily Failure to do causes internal tank corrosion perforation and ultimate failure The following is the moisture draining procedure for the optionally available Eastwood 32501 80 Gallon Vertical...

Страница 16: ...the Oil Fill Plug from the upper side of the Oil Reservoir with a 22mm wrench not included FIG 35 4 Unroll the transparent Oil Drain Tube and place the open end into a suitable container FIG 36 5 Open...

Страница 17: ...Replace Oil Fill Plug and tighten securely 9 Restore power to Compressor Depress the START Button run Compressor and check for leaks 10 Press the OFF Button and replace all panels AIR FILTER CHANGE 1...

Страница 18: ...l line compression fitting at the 90 elbow attached to the Head Plate with a 14mm line wrench not included FIG 43 8 Detach the oil outflow line leading from the center of the Head Plate with a 14mm li...

Страница 19: ...line fitting 4 Reconnect the oil line compression fitting at the 90 elbow attached to the Head NOTE Use caution not to cross thread the compression nut on the stationary line fitting 5 Thread in the r...

Страница 20: ...ower 3 Phase input voltage too low Determine the cause of low input voltage condition or consult a licensed electrician for diagnosis Compressor being operated in exces sively low under 32 F 0 C ambie...

Отзывы: