Troubleshooting 29
Troubleshooting
Problem
Solution
No Element Heat
•
Check to be sure sealer is plugged in and
electrical power is present at the outlet.
•
Is the temperature control dial for the heat
element, Front or Side set greater than
zero? If not, check main fuses
- Heat element temperature control must be
set to a number greater than zero (0).
The greater the number the dial is set to, the
higher the heat setting for the element.
Conveyor Does Not Run
•
Is the conveyor speed dial, set to zero (0)?
- Conveyor speed dial must be set to a
number greater than zero (0).
The greater the number the dial is set to, the
longer the conveyor will run each cycle, with
zero indicating the very minimum, in which
case it may not run for any time at all.
•
Is the limit switch on the back of the
machine being fully actuated (pressed in)?
- Press the limit switch in by hand, and then
let it go.
- Refer to Magnet Hold Down Not Operating
on Magnet Sealers, below.
Magnet Hold Down Magnets Not
Operating on Magnet Sealers
(Sealing head will not stay down,
but
sealer operates normally
otherwise.)
•
Is timer working properly?
- The timer is identical to the timer used for
the Conveyor. See items to check on the
conveyor timer for Conveyor Does Not
Run troubleshooting on previous page.
•
Turn off power and put the seal head down.
With power off and the seal head down,
there should be about a dime’s-thickness of
space between the upper and lower
magnets.
- Is there dime-sized space between upper
and lower magnets?
•
Press the limit switch to activate it by hand.
- Does the limit switch work properly when
operated by hand?