microBrute DRSSTC Tesla Coil Kit
November 2019, Rev 5
− 35 −
Copyright © 2011, Eastern Voltage Research, LLC
microBrute DRSSTC Instruction Manual
hear the frequency of this pulsing change. Set the PW adjustment knob back to 0
and turn the power switch OFF.
13. Now its time to set the initial current set limit. Using a multimeter, monitor
the voltage across capacitor, C25, while adjusting potentiometer, R23. Set the
voltage to 0.7V. This sets the max current limit to 150A.
14. At this point, the low voltage testing has been completed for the microBrute
DRSSTC. Unplug the Control Power power cord and ensure the microBrute
handheld controller power switch is in the OFF position.
We are now ready to test the microBrute DRSSTC with Resonator Power applied.
Please review the following warnings before proceeding:
The Output Arc of the Tesla Coil is at high voltage potential and extremely
hot. Never attempt to touch the arc or draw arcs using any type of object.
Protective Eyewear is REQUIRED at all times when operating the microBrute
DRSSTC.
Hearing Protection is REQUIRED at all times when operating the microBrute
DRSSTC.
DO NOT stand close to the microBrute DRSSTC system when Resonator
Power is applied. Stand back at least five (5) feet from the microBrute
DRSSTC system.
15. Verify that the microBrute DRSSTC handheld controller is plugged into the
jack labeled, J1 MOD INPUT. Set the PRF adjustment knob to 50% and the PW
adjustment knob to 0. Ensure the power switch is in the OFF position.
16. Plug in the Control Power AC power cord at this time.
17. Turn the microBrute handheld controller ON.