 INTRODUCTION

Features:

Triple displays of 

 level, temp. 

and humidity (7722/77232)

s

 

calibration

PC connect 

CO

2

Stable NDIR sensor for CO  detection

2

Statistics of weighted average

TWA (8 hours weighted average)

 STEL(15 minutes weighted average)

Visible and audile CO  warning alarm

2

Alarm output for ventilation control
ABC(Automatic Baseline Calibration)
and manual CO  

2

via RS232 interface

1

Thank you for purchasing this wall mo unt
CO  mo nitor. It could me asure the CO  

2

2

level, air temp ., dew point, wet bulb temp . 
and humi dity (DP, WB , RH are for mo dels 
7722/77232) and is an ideal instrume nt 
for indoor air quality (IAQ)  diagnosis. 

Poor indoor air quality is considered 
unhealthy because it causes tiredness, 
loss of ability to concentrate, and even 
illness(ex. Sick Building Syndrome ). IAQ 
mo nitoring and survey, especially on CO  

2

level and air ventilation become widely 
applied in public areas such as offices, 
classrooms , factories, hospitals and 
hotels. It is also suggested in regulations 
of industrial hygiene in some countries. 
(See appendix) 

Wi th NDIR (non-dispersive infrared) 
sensor used, this CO  mo nitor is stable 

2

in long term mo nitoring. And the built-in 
alarm output is especially helpful in 
ventilation control and HVAC system 
performa nce verification. 

Содержание 7721

Страница 1: ...AL WALL MOUNT CO MONITOR 2 Model 7722 77232 www ete co th EASTERN ENERGY CO LTD HEAD OFFICE 40 4 Vitoondumri Rd Banbueng Banbueng Contact Tel 0 3844 6117 Fax 0 3844 6200 Email info ete co th Banbueng...

Страница 2: ...P WB RH are for models 7722 77232 and is an ideal instrument for indoor air quality IAQ diagnosis Poor indoor air quality is considered unhealthy because it causes tiredness loss of ability to concent...

Страница 3: ...STEL hort term exposure limit 15 minutes weighted DP Dew point temp 7722 77232 AIR Air temp WBT Wet bulb temp 7722 77232 Unit of relative humidity o E C F Celsius Fahrenheit AVG CO ALM HLD MAX MIN Max...

Страница 4: ...Activate MAX MIN STEL TWA function Select mode or decrease value in calibration and setup KEYPAD SET SET CAL ESC CAL ESC DP WB M X N AVG RESET RESET DP WB M X N AVG OPERATION Plug in the adaptor and t...

Страница 5: ...CO sensor and 30 minutes for RH 2 AIR all models DP WBT 7722 77232 DP WB PPM PPM Under normal mode press key to see the minimum maximum and weighted average readings Press key it displays MIN MAX STE...

Страница 6: ...the weighted average of readings taken since power on Same for the TWA value 2 It takes at least 5 minutes to calculate the STEL and TWA value The LCD shows Fig 7 during the first 5 minutes from powe...

Страница 7: ...system or activator for conditioning the air quality The relay will drop out when CO readings fall below the lower limit 2 If the beeper is temporarily shut it will sound again when readings fall bel...

Страница 8: ...limit The current setting 2 value will be blinking on the LCD Fig 9 CAUTION It s suggested to set up the alarm value within specification range that accuracy is ensured The out of spec readings are o...

Страница 9: ...SELECTION Fig 11 ABC Automatic Baseline Calibration is to implement baseline calibration to eliminate the zero drift of the infrared sensor The ABC function default is on when turning on the meter Us...

Страница 10: ...standard 400ppm CO concentration in factory 2 It s suggested to do either ABC or manual calibration regularly to maintain the good accuracy Fig 14 Fig 15 CO2 CO2 Press key enter P4 1 with blinking en...

Страница 11: ...ce the meter in the calibration site Turn on the meter and hold and keys simultaneously to enter CO2 calibration mode Fig 16 400ppm and CAL are blinking on the LCD while performing calibration CAL ESC...

Страница 12: ...ating value To stop calibration hold key for more than 1 sec at any time 7722 77232 RH CALIBRATION O O Fig 17 O O Fig 18 After 33 calibration plug the sensor probe into 75 salt bottle then press key t...

Страница 13: ...inking stops then calibration is completed and it returns to normal mode Error messages E01 CO sensor damaged 2 E02 The value is under range E03 The value is over range E04 The original data error res...

Страница 14: ...2 77231 77232 Resolution Accuracy Pressure Dependence Range Resolution Accuracy Range N A 0 0 99 9 N A 0 0 99 9 Resolution N A 0 1 N A 0 1 3 10 90 3 10 90 5 others 5 others Warm up Operating Storage P...

Страница 15: ...RIZATION OTHER RELATED PRODUCTS Authorization must be obtained from the supplier before returning items for any reason When requiring a RA Return Authorization please include data regarding the defect...

Страница 16: ...000ppm indicates inadequate ventilation complaints such as headaches fatigue and eye throat irritation will be more widespread 1000ppm should be used as an upper limit for indoor levels Non Enforced R...

Страница 17: ...meter Infrared Thermometer K type Thermometer pH Meter Conductivity Meter T D S Meter D O Meter Lux Light Meter Data logger Temp RH transmitter Wireless Transmitter 2013 08 Ver3 www ete co th EASTERN...